Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system.

Laurence Court1, Isaac Rosen, Radhe Mohan, Lei Dong.   

Abstract

A new integrated CT/LINAC combination, in which the CT scanner is inside the radiation therapy treatment room and the same patient couch is used for CT scanning and treatment (after a 180-degree couch rotation), should allow for accurate correction of interfractional setup errors. The purpose of this study was to evaluate the sources of uncertainties, and to measure the overall precision of this system. The following sources of uncertainty were identified: (1) the patient couch position on the LINAC side after a rotation, (2) the patient couch position on the CT side after a rotation, (3) the patient couch position as indicated by its digital readout, (4) the difference in couch sag between the CT and LINAC positions, (5) the precision of the CT coordinates, (6) the identification of fiducial markers from CT images, (7) the alignment of contours with structures in the CT images, and (8) the alignment with setup lasers. The largest single uncertainties (one standard deviation or 1 SD) were found in couch position on the CT side after a rotation (0.5 mm in the RL direction) and the alignment of contours with the CT images (0.4 mm in the SI direction). All other sources of uncertainty are less than 0.3 mm (1 SD). The overall precision of two setup protocols was investigated in a controlled phantom study. A protocol that relies heavily on the mechanical integrity of the system, and assumes a fixed relationship between the LINAC isocenter and the CT images, gave a predicted precision (1 SD) of 0.6, 0.7, and 0.6 mm in the SI, RL and AP directions, respectively. The second protocol reduces reliance on the mechanical precision of the total system, particularly the patient couch, by using radio-opaque fiducial markers to transfer the isocenter information from the LINAC side to the CT images. This protocol gave a slightly improved predicted precision of 0.5, 0.4, and 0.4 mm in the SI, RL and AP directions, respectively. The distribution of phantom position after CT-based correction confirmed these results. Knowledge of the individual sources of uncertainty will allow alternative setup protocols to be evaluated in the future without the need for significant additional measurements.

Entities:  

Mesh:

Year:  2003        PMID: 12852544     DOI: 10.1118/1.1573792

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Evaluations of an adaptive planning technique incorporating dose feedback in image-guided radiotherapy of prostate cancer.

Authors:  Han Liu; Qiuwen Wu
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

Review 2.  Current progress in adaptive radiation therapy for head and neck cancer.

Authors:  David L Schwartz
Journal:  Curr Oncol Rep       Date:  2012-04       Impact factor: 5.075

3.  Variable planning margin approach to account for locoregional variations in setup uncertainties.

Authors:  Jinzhong Yang; Adam S Garden; Yongbin Zhang; Lifei Zhang; Lei Dong
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

4.  Predicting oropharyngeal tumor volume throughout the course of radiation therapy from pretreatment computed tomography data using general linear models.

Authors:  Adam D Yock; Arvind Rao; Lei Dong; Beth M Beadle; Adam S Garden; Rajat J Kudchadker; Laurence E Court
Journal:  Med Phys       Date:  2014-05       Impact factor: 4.071

5.  Reduction of prostate intrafractional motion from shortening the treatment time.

Authors:  Jin Sheng Li; Mu-Han Lin; Mark K Buyyounouski; Eric M Horwitz; Chang-Ming Ma
Journal:  Phys Med Biol       Date:  2013-06-25       Impact factor: 3.609

6.  Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators.

Authors:  Youcef El-Mohri; Larry E Antonuk; Qihua Zhao; Richard B Choroszucha; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2011-02-16       Impact factor: 3.609

7.  Adaptive radiation therapy for head and neck cancer-can an old goal evolve into a new standard?

Authors:  David L Schwartz; Lei Dong
Journal:  J Oncol       Date:  2010-08-18       Impact factor: 4.375

8.  Is a 3-mm intrafractional margin sufficient for daily image-guided intensity-modulated radiation therapy of prostate cancer?

Authors:  Adam D Melancon; Jennifer C O'Daniel; Lifei Zhang; Rajat J Kudchadker; Deborah A Kuban; Andrew K Lee; Rex M Cheung; Renaud de Crevoisier; Susan L Tucker; Wayne D Newhauser; Radhe Mohan; Lei Dong
Journal:  Radiother Oncol       Date:  2007-09-24       Impact factor: 6.280

9.  Parotid gland dose in intensity-modulated radiotherapy for head and neck cancer: is what you plan what you get?

Authors:  Jennifer C O'Daniel; Adam S Garden; David L Schwartz; He Wang; Kian K Ang; Anesa Ahamad; David I Rosenthal; William H Morrison; Joshua A Asper; Lifei Zhang; Shih-Ming Tung; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-15       Impact factor: 7.038

10.  Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method.

Authors:  He Wang; Adam S Garden; Lifei Zhang; Xiong Wei; Anesa Ahamad; Deborah A Kuban; Ritsuko Komaki; Jennifer O'Daniel; Yongbin Zhang; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-01       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.