Literature DB >> 17881799

GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration.

G C Sharp1, N Kandasamy, H Singh, M Folkert.   

Abstract

This paper shows how to significantly accelerate cone-beam CT reconstruction and 3D deformable image registration using the stream-processing model. We describe data-parallel designs for the Feldkamp, Davis and Kress (FDK) reconstruction algorithm, and the demons deformable registration algorithm, suitable for use on a commodity graphics processing unit. The streaming versions of these algorithms are implemented using the Brook programming environment and executed on an NVidia 8800 GPU. Performance results using CT data of a preserved swine lung indicate that the GPU-based implementations of the FDK and demons algorithms achieve a substantial speedup--up to 80 times for FDK and 70 times for demons when compared to an optimized reference implementation on a 2.8 GHz Intel processor. In addition, the accuracy of the GPU-based implementations was found to be excellent. Compared with CPU-based implementations, the RMS differences were less than 0.1 Hounsfield unit for reconstruction and less than 0.1 mm for deformable registration.

Entities:  

Mesh:

Year:  2007        PMID: 17881799     DOI: 10.1088/0031-9155/52/19/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  59 in total

1.  Ultrafast and scalable cone-beam CT reconstruction using MapReduce in a cloud computing environment.

Authors:  Bowen Meng; Guillem Pratx; Lei Xing
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Development of a GPU-based multithreaded software application to calculate digitally reconstructed radiographs for radiotherapy.

Authors:  Shinichiro Mori; Masanao Kobayashi; Motoki Kumagai; Shinichi Minohara
Journal:  Radiol Phys Technol       Date:  2008-11-07

3.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

4.  Motion artefacts in cone beam CT: an in vitro study about the effects on the images.

Authors:  Cosimo Nardi; Roberto Molteni; Chiara Lorini; Gian G Taliani; Benedetta Matteuzzi; Elisa Mazzoni; Stefano Colagrande
Journal:  Br J Radiol       Date:  2015-11-18       Impact factor: 3.039

5.  Canny edge-based deformable image registration.

Authors:  Vasant Kearney; Yihui Huang; Weihua Mao; Baohong Yuan; Liping Tang
Journal:  Phys Med Biol       Date:  2017-01-12       Impact factor: 3.609

6.  Lung texture in serial thoracic CT scans: correlation with radiologist-defined severity of acute changes following radiation therapy.

Authors:  Alexandra R Cunliffe; Samuel G Armato; Christopher Straus; Renuka Malik; Hania A Al-Hallaq
Journal:  Phys Med Biol       Date:  2014-08-26       Impact factor: 3.609

7.  Local label learning (LLL) for subcortical structure segmentation: application to hippocampus segmentation.

Authors:  Yongfu Hao; Tianyao Wang; Xinqing Zhang; Yunyun Duan; Chunshui Yu; Tianzi Jiang; Yong Fan
Journal:  Hum Brain Mapp       Date:  2013-10-23       Impact factor: 5.038

8.  CT to cone-beam CT deformable registration with simultaneous intensity correction.

Authors:  Xin Zhen; Xuejun Gu; Hao Yan; Linghong Zhou; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

9.  Four-dimensional deformable image registration using trajectory modeling.

Authors:  Edward Castillo; Richard Castillo; Josue Martinez; Maithili Shenoy; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

10.  High throughput transmission optical projection tomography using low cost graphics processing unit.

Authors:  Claudio Vinegoni; Lyuba Fexon; Paolo Fumene Feruglio; Misha Pivovarov; Jose-Luiz Figueiredo; Matthias Nahrendorf; Antonio Pozzo; Andrea Sbarbati; Ralph Weissleder
Journal:  Opt Express       Date:  2009-12-07       Impact factor: 3.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.