Literature DB >> 14596313

Automatic registration of the prostate for computed-tomography-guided radiotherapy.

Laurence E Court1, Lei Dong.   

Abstract

The recent development of integrated computed tomography (CT)/linear accelerator (LINAC) combinations, where the CT scanner and the LINAC use the same patient couch, and of kilovoltage cone-beam CT systems attached to the LINAC gantry, means that suitable hardware is now available for CT-guided localization of the prostate. Clinical implementation is, however, currently impeded by the lack of robust and accurate software tools to compare the position of the prostate in the CT images used for the treatment plan with its position in the daily CT images. Manual registration of the planning CT images with the daily CT images can be slow and can introduce significant inter-user variations. We have developed an automatic registration technique that is not adversely influenced by changes in prostate shape, size or orientation, presence of rectal gas, or bladder filling. The cost function used in the registration is the mean absolute difference in CT numbers voxel-by-voxel between the daily CT image and the planning CT image for a volume extracted from the planning CT images using the original physician-drawn gross tumor volume contours. To enhance soft tissue contrast in the prostate region and to reduce the impact of rectal gas calcifications and bone on the registration, voxels with CT numbers that represent gas or bone are filtered out from the calculation. The results of the automatic registration agreed with the mean results of seven human observers, with standard deviations of 0.5 mm, 0.5 mm, and 1.0 mm in the left/right (RL), anterior/posterior (AP), and superior/inferior (SI) directions, respectively, for a patient that was relatively easy to localize. Agreement (one standard deviation) for a patient that was difficult to localize was 0.6 mm, 1.4 mm, and 1.9 mm in the RL, AP, and SI directions, respectively. These results are better than the interuser uncertainties reported for a manual alignment technique and are close to the reported intrauser uncertainties. The results are independent of the shape of contours in the original treatment plan, reducing the impact of interobserver variations in contouring the prostate. The algorithm is fast and reliable, allowing the entire CT localization process to take place in 5-9 minutes. In 120 CT image sets from seven patients, the failure rate was found to be less than 1%. The use of this algorithm will facilitate the clinical implementation of CT-guided localization of the prostate.

Entities:  

Mesh:

Year:  2003        PMID: 14596313     DOI: 10.1118/1.1608497

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

Review 1.  Technological advances in radiation therapy for prostate cancer.

Authors:  Mehee Choi; Arthur Y Hung
Journal:  Curr Urol Rep       Date:  2010-05       Impact factor: 3.092

2.  Automated registration of hip and spine for longitudinal QCT studies: integration with 3D densitometric and structural analysis.

Authors:  Wenjun Li; Miki Sode; Isra Saeed; Thomas Lang
Journal:  Bone       Date:  2005-09-30       Impact factor: 4.398

3.  Feature-based rectal contour propagation from planning CT to cone beam CT.

Authors:  Yaoqin Xie; Ming Chao; Percy Lee; Lei Xing
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  A novel approach for establishing benchmark CBCT/CT deformable image registrations in prostate cancer radiotherapy.

Authors:  Jinkoo Kim; Sanath Kumar; Chang Liu; Hualiang Zhong; Deepak Pradhan; Mira Shah; Richard Cattaneo; Raphael Yechieli; Jared R Robbins; Mohamed A Elshaikh; Indrin J Chetty
Journal:  Phys Med Biol       Date:  2013-10-31       Impact factor: 3.609

5.  Multi-system verification of registrations for image-guided radiotherapy in clinical trials.

Authors:  Yunfeng Cui; James M Galvin; William L Straube; Walter R Bosch; James A Purdy; X Allen Li; Ying Xiao
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-01-13       Impact factor: 7.038

6.  Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate.

Authors:  Douglas J Moseley; Elizabeth A White; Kirsty L Wiltshire; Tara Rosewall; Michael B Sharpe; Jeffrey H Siewerdsen; Jean-Pierre Bissonnette; Mary Gospodarowicz; Padraig Warde; Charles N Catton; David A Jaffray
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-01       Impact factor: 7.038

7.  Differences between planned and delivered dose for head and neck cancer, and their consequences for normal tissue complication probability and treatment adaptation.

Authors:  Jolien Heukelom; Michael E Kantor; Abdallah S R Mohamed; Hesham Elhalawani; Esengul Kocak-Uzel; Timothy Lin; Jinzhong Yang; Michalis Aristophanous; Coen R Rasch; Clifton David Fuller; Jan-Jakob Sonke
Journal:  Radiother Oncol       Date:  2019-08-17       Impact factor: 6.280

8.  Is a 3-mm intrafractional margin sufficient for daily image-guided intensity-modulated radiation therapy of prostate cancer?

Authors:  Adam D Melancon; Jennifer C O'Daniel; Lifei Zhang; Rajat J Kudchadker; Deborah A Kuban; Andrew K Lee; Rex M Cheung; Renaud de Crevoisier; Susan L Tucker; Wayne D Newhauser; Radhe Mohan; Lei Dong
Journal:  Radiother Oncol       Date:  2007-09-24       Impact factor: 6.280

9.  A novel dose-based positioning method for CT image-guided proton therapy.

Authors:  Joey P Cheung; Peter C Park; Laurence E Court; X Ronald Zhu; Rajat J Kudchadker; Steven J Frank; Lei Dong
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

10.  Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method.

Authors:  He Wang; Adam S Garden; Lifei Zhang; Xiong Wei; Anesa Ahamad; Deborah A Kuban; Ritsuko Komaki; Jennifer O'Daniel; Yongbin Zhang; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-01       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.