PURPOSE: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. METHODS: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1-C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. RESULTS: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. CONCLUSIONS: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.
PURPOSE: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. METHODS: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1-C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. RESULTS: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. CONCLUSIONS: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.
Authors: David Mattes; David R Haynor; Hubert Vesselle; Thomas K Lewellen; William Eubank Journal: IEEE Trans Med Imaging Date: 2003-01 Impact factor: 10.048
Authors: Choonik Lee; Katja M Langen; Weiguo Lu; Jason Haimerl; Eric Schnarr; Kenneth J Ruchala; Gustavo H Olivera; Sanford L Meeks; Patrick A Kupelian; Thomas D Shellenberger; Rafael R Mañon Journal: Int J Radiat Oncol Biol Phys Date: 2008-06-04 Impact factor: 7.038
Authors: Xiao Han; Mischa S Hoogeman; Peter C Levendag; Lyndon S Hibbard; David N Teguh; Peter Voet; Andrew C Cowen; Theresa K Wolf Journal: Med Image Comput Comput Assist Interv Date: 2008
Authors: Choonik Lee; Katja M Langen; Weiguo Lu; Jason Haimerl; Eric Schnarr; Kenneth J Ruchala; Gustavo H Olivera; Sanford L Meeks; Patrick A Kupelian; Thomas D Shellenberger; Rafael R Mañon Journal: Radiother Oncol Date: 2008-08-15 Impact factor: 6.280
Authors: Lianli Liu; Adam Johansson; Yue Cao; Janell Dow; Theodore S Lawrence; James M Balter Journal: Phys Med Biol Date: 2020-06-15 Impact factor: 3.609
Authors: Robin Strand; Filip Malmberg; Lars Johansson; Lars Lind; Magnus Sundbom; Håkan Ahlström; Joel Kullberg Journal: PLoS One Date: 2017-02-27 Impact factor: 3.240