Literature DB >> 18683224

In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants.

Danieli C Rodrigues1, Robert M Urban, Joshua J Jacobs, Jeremy L Gilbert.   

Abstract

Titanium alloys are widely used in total-joint replacements due to a combination of outstanding mechanical properties, biocompatibility, passivity, and corrosion resistance. Nevertheless, retrieval studies have pointed out that these materials can be subjected to localized or general corrosion in modular interfaces when mechanical abrasion of the oxide film (fretting) occurs. Modularity adds large crevice environments, which are subject to micromotion between contacting interfaces and differential aeration of the surface. Titanium alloys are also known to be susceptible to hydrogen absorption, which can induce precipitation of hydrides and subsequent brittle failure. In this work, the surface of three designs of retrieved hip-implants with Ti-6Al-4V/Ti-6Al-4V modular taper interfaces in the stem were investigated for evidence of severe corrosion and precipitation of brittle hydrides during fretting-crevice corrosion in the modular connections. The devices were retrieved from patients and studied by means of scanning electron microscopy (SEM), X-ray diffraction (XRD), and chemical analysis. The surface qualitative investigation revealed severe corrosion attack in the mating interfaces with evidence of etching, pitting, delamination, and surface cracking. In vivo hydrogen embrittlement was shown to be a mechanism of degradation in modular connections resulting from electrochemical reactions induced in the crevice environment of the tapers during fretting-crevice corrosion. (c) 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 18683224      PMCID: PMC2667129          DOI: 10.1002/jbm.b.31171

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  16 in total

1.  The long-term success of modular proximal fixation stems in revision total hip arthroplasty.

Authors:  Hugh U Cameron
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

2.  Orthopaedic crossfire--Stem modularity is unnecessary in revision total hip arthroplasty: in the affirmative.

Authors:  Robert L Barrack
Journal:  J Arthroplasty       Date:  2003-04       Impact factor: 4.757

3.  In vitro corrosion testing of modular hip tapers.

Authors:  Jay R Goldberg; Jeremy L Gilbert
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2003-02-15       Impact factor: 3.368

4.  A multicenter retrieval study of the taper interfaces of modular hip prostheses.

Authors:  Jay R Goldberg; Jeremy L Gilbert; Joshua J Jacobs; Thomas W Bauer; Wayne Paprosky; Sue Leurgans
Journal:  Clin Orthop Relat Res       Date:  2002-08       Impact factor: 4.176

5.  Crevice corrosion in orthopedic implant metals.

Authors:  D L Levine; R W Staehle
Journal:  J Biomed Mater Res       Date:  1977-07

6.  In vitro electrochemical corrosion study of coupled surgical implant materials.

Authors:  C D Griffin; R A Buchanan; J E Lemons
Journal:  J Biomed Mater Res       Date:  1983-05

7.  In vitro studies of fretting corrosion of orthopaedic materials.

Authors:  S A Brown; P J Hughes; K Merritt
Journal:  J Orthop Res       Date:  1988       Impact factor: 3.494

8.  The effect of temperature on the nucleation of corrosion pits on titanium in Ringer's physiological solution.

Authors:  G T Burstein; C Liu; R M Souto
Journal:  Biomaterials       Date:  2005-01       Impact factor: 12.479

9.  Pain in the well-fixed, aseptic titanium hip replacement. The role of corrosion.

Authors:  P Hallam; F Haddad; J Cobb
Journal:  J Bone Joint Surg Br       Date:  2004-01

10.  Stem modularity: rarely necessary in primary total hip arthroplasty.

Authors:  Adolph V Lombardi; Thomas H Mallory; Robert A Fada; Joanne B Adams
Journal:  Orthopedics       Date:  2002-12       Impact factor: 1.390

View more
  21 in total

Review 1.  What is the trouble with trunnions?

Authors:  Christina I Esposito; Timothy M Wright; Stuart B Goodman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

2.  In vivo degradation of orthodontic miniscrew implants: surface analysis of as-received and retrieved specimens.

Authors:  Masahiro Iijima; Takeshi Muguruma; Masahiro Kawaguchi; Yoshitaka Yasuda; Itaru Mizoguchi
Journal:  J Mater Sci Mater Med       Date:  2015-01-29       Impact factor: 3.896

3.  Cathodic Electrical Stimulation Combined With Vancomycin Enhances Treatment of Methicillin-resistant Staphylococcus aureus Implant-associated Infections.

Authors:  Scott Nodzo; Menachem Tobias; Lisa Hansen; Nicole R Luke-Marshall; Ross Cole; Linda Wild; Anthony A Campagnari; Mark T Ehrensberger
Journal:  Clin Orthop Relat Res       Date:  2015-09       Impact factor: 4.176

4.  Microstructure and electrochemical behavior of contemporary Ti6Al4V implant alloys.

Authors:  Mozart Queiroz Neto; Simona Radice; Deborah J Hall; Nicholas B Frisch; Mathew T Mathew; Alfons Fischer; Joshua J Jacobs; Robin Pourzal
Journal:  J Bio Tribocorros       Date:  2021-12-24

5.  Fretting-corrosion in Hip Implant Modular Junctions: New Experimental Set-up and Initial Outcome.

Authors:  D Royhman; M Patel; M J Runa; J J Jacobs; N J Hallab; M A Wimmer; M T Mathew
Journal:  Tribol Int       Date:  2015-11-01       Impact factor: 4.872

6.  Properties and Corrosion Performance of Self-reinforced Composite PEEK for Proposed Use as a Modular Taper Gasket.

Authors:  Eric S Ouellette; Jeremy L Gilbert
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

7.  Investigation of the early healing response to dicationic imidazolium-based ionic liquids: a biocompatible coating for titanium implants.

Authors:  Sutton E Wheelis; Claudia C Biguetti; Shruti Natarajan; Lidia Guida; Brian Hedden; Gustavo P Garlet; Danieli C Rodrigues
Journal:  ACS Biomater Sci Eng       Date:  2020-01-14

Review 8.  Head-neck taper corrosion in hip arthroplasty.

Authors:  S Hussenbocus; D Kosuge; L B Solomon; D W Howie; R H Oskouei
Journal:  Biomed Res Int       Date:  2015-04-14       Impact factor: 3.411

9.  Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.

Authors:  Thomas M Grupp; Thomas Weik; Wilhelm Bloemer; Hanns-Peter Knaebel
Journal:  BMC Musculoskelet Disord       Date:  2010-01-04       Impact factor: 2.362

10.  Clinical Outcomes of Tibial Components with Modular Stems Used in Primary TKA.

Authors:  Nicole Durig; Thomas Pace; Brandon Broome; Obi Osuji; Melinda K Harman
Journal:  Adv Orthop       Date:  2014-02-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.