Literature DB >> 25825157

Cathodic Electrical Stimulation Combined With Vancomycin Enhances Treatment of Methicillin-resistant Staphylococcus aureus Implant-associated Infections.

Scott Nodzo1, Menachem Tobias, Lisa Hansen, Nicole R Luke-Marshall, Ross Cole, Linda Wild, Anthony A Campagnari, Mark T Ehrensberger.   

Abstract

BACKGROUND: Effective treatments for implant-associated infections are often lacking. Cathodic voltage-controlled electrical stimulation has shown potential as a treatment of implant-associated infections of methicillin-resistant Staphylococcus aureus (MRSA). QUESTIONS/PURPOSES: The primary purpose of this study was to (1) determine if cathodic voltage-controlled electrical stimulation combined with vancomycin therapy is more effective at reducing the MRSA bacterial burden on the implant, bone, and synovial fluid in comparison to either treatment alone or no treatment controls. We also sought to (2) evaluate the histologic effects of the various treatments on the surrounding bone; and to (3) determine if the cathodic voltage-controlled electrical stimulation treatment had an effect on the mechanical properties of the titanium implant as a result of possible hydrogen embrittlement.
METHODS: Thirty-two adult male Long-Evans rats (Harlan Laboratories, Indianapolis, IN, USA) with surgically placed shoulder titanium implants were infected with a clinical strain of MRSA (NRS70). One week after infection, eight animals received a treatment of cathodic voltage-controlled electrical stimulation at -1.8 V versus Ag/AgCl for 1 hour (STIM), eight received vancomycin twice daily for 1 week (VANCO), eight received the cathodic voltage-controlled electrical stimulation and vancomycin therapy combined (STIM + VANCO), and eight served as controls with no treatment (CONT). Two weeks after initial infection, the implant, bone, and synovial fluid were collected for colony-forming unit (CFU) enumeration, qualitative histological analysis by a pathologist blinded to the treatments each animal received, and implant three-point bend testing.
RESULTS: The implant-associated CFU enumerated from the STIM + VANCO (mean, 3.7 × 10(3); SD, 6.3 × 10(3)) group were less than those from the CONT (mean, 1.3 × 10(6); SD, 2.8 × 10(6); 95% confidence interval [CI] of difference, -4.3 × 10(5) to -9.9 × 10(3); p < 0.001), STIM (mean, 1.4 × 10(6); SD, 2.0 × 10(6); 95% CI of difference, -2.1 × 10(6) to -1.8 × 10(3); p = 0.002), and VANCO (mean, 5.8 x 10(4); SD, 5.7 × 10(4); 95% CI of difference, -6.4 × 10(4) to -1.7 × 10(4); p < 0.001) group. The bone-associated CFU enumerated from the STIM + VANCO group (6.3 × 10(1); SD, 1.1 × 10(2)) were less than those from the CONT (mean, 2.8 × 10(5); SD, 4.8 × 10(5); 95% CI of difference, -9.4 × 10(4) to -5.0 × 10(3); p < 0.001) and STIM (mean, 2.6 × 10(4); SD, 2.5 × 10(4); 95% CI of difference, -4.1 × 10(4) to -1.6 × 10(3); p < 0.001) groups. The VANCO group (4.3 × 10(5); SD, 6.3 × 10(2)) also had lower bone-associated CFU as compared with the CONT (mean 95% CI of difference, -9.3 × 10(4) to -4.5 × 10(3); p < 0.001) and STIM (95% CI of difference, -4.0 × 10(4) to -1.5 × 10(3); p < 0.001) groups. In comparison to the synovial fluid CFU enumerated from the CONT group (mean, 3.3 × 10(4); SD, 6.0 × 10(4)), lower synovial CFU were reported for both the STIM + VANCO group (mean, 4.6 × 10(1); SD, 1.2 × 10(2); 95% CI of difference, -4.9 × 10(3) to -3.0 × 10(2); p < 0.001) and the VANCO group (mean, 6.8 × 10(1); SD, 9.2 × 10(1); 95% CI of difference, -4.9 × 10(3) to -2.8 × 10(2); p = 0.007). The histological analysis showed no discernable deleterious effects on the surrounding tissue as a result of the treatments. No brittle fracture occurred during mechanical testing and with the numbers available, no differences in implant flexural yield strength were detected between the groups.
CONCLUSIONS: In this rodent model, cathodic voltage-controlled electrical stimulation combined with vancomycin is an effective treatment for titanium implant-associated infections showing greater than 99.8% reduction in bacterial burden on the implant, surrounding bone, and synovial fluid as compared with the controls and the stimulation alone groups. CLINICAL RELEVANCE: Cathodic voltage-controlled electrical stimulation combined with vancomycin may enable successful treatment of titanium orthopaedic implant-associated infections with implant retention. Future studies will focus on optimization of the stimulation parameters for complete eradication of infection and the ability to promote beneficial host tissue responses.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25825157      PMCID: PMC4523523          DOI: 10.1007/s11999-015-4280-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  31 in total

Review 1.  Use of antibiotic-impregnated cement in total joint arthroplasty.

Authors:  Thomas N Joseph; Andrew L Chen; Paul E Di Cesare
Journal:  J Am Acad Orthop Surg       Date:  2003 Jan-Feb       Impact factor: 3.020

2.  Electrical enhancement of biocide efficacy against Pseudomonas aeruginosa biofilms.

Authors:  S A Blenkinsopp; A E Khoury; J W Costerton
Journal:  Appl Environ Microbiol       Date:  1992-11       Impact factor: 4.792

Review 3.  Biofilm theory can guide the treatment of device-related orthopaedic infections.

Authors:  J William Costerton
Journal:  Clin Orthop Relat Res       Date:  2005-08       Impact factor: 4.176

4.  Prevention of pin tract infection in external stainless steel fixator frames using electric current in a goat model.

Authors:  Arnout J van der Borden; Patrick G M Maathuis; Eefje Engels; Gerhard Rakhorst; Henny C van der Mei; Henk J Busscher; Prashant Kumar Sharma
Journal:  Biomaterials       Date:  2007-01-04       Impact factor: 12.479

5.  Can this prosthesis be saved?: implant salvage attempts in infected primary TKA.

Authors:  Jeremy Gardner; Terence J Gioe; Penny Tatman
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

6.  Local delivery of vancomycin for the prophylaxis of prosthetic device-related infections.

Authors:  Dakshina M Chilukuri; Jaymin C Shah
Journal:  Pharm Res       Date:  2005-04-07       Impact factor: 4.200

7.  Controlling Pseudomonas aeruginosa persister cells by weak electrochemical currents and synergistic effects with tobramycin.

Authors:  Tagbo H R Niepa; Jeremy L Gilbert; Dacheng Ren
Journal:  Biomaterials       Date:  2012-07-25       Impact factor: 12.479

8.  Electric-current-induced detachment of Staphylococcus epidermidis strains from surgical stainless steel.

Authors:  A J van der Borden; H C van der Mei; H J Busscher
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-02-15       Impact factor: 3.368

9.  Comparative efficacy of daptomycin and vancomycin in the therapy of experimental foreign body infection due to Staphylococcus aureus.

Authors:  Pierre Vaudaux; Patrice Francois; Carmelo Bisognano; Dongmei Li; Daniel P Lew; Jacques Schrenzel
Journal:  J Antimicrob Chemother       Date:  2003-05-29       Impact factor: 5.790

10.  The electricidal effect is active in an experimental model of Staphylococcus epidermidis chronic foreign body osteomyelitis.

Authors:  Jose L Del Pozo; Mark S Rouse; Gorane Euba; Cheol-In Kang; Jayawant N Mandrekar; James M Steckelberg; Robin Patel
Journal:  Antimicrob Agents Chemother       Date:  2009-08-03       Impact factor: 5.191

View more
  6 in total

1.  CORR Insights(®): Cathodic Voltage-controlled Electrical Stimulation Plus Prolonged Vancomycin Reduce Bacterial Burden of a Titanium Implant-associated Infection in a Rodent Model.

Authors:  Charalampos G Zalavras
Journal:  Clin Orthop Relat Res       Date:  2016-02-16       Impact factor: 4.176

2.  Cathodic Voltage-controlled Electrical Stimulation Plus Prolonged Vancomycin Reduce Bacterial Burden of a Titanium Implant-associated Infection in a Rodent Model.

Authors:  Scott R Nodzo; Menachem Tobias; Richard Ahn; Lisa Hansen; Nicole R Luke-Marshall; Craig Howard; Linda Wild; Anthony A Campagnari; Mark T Ehrensberger
Journal:  Clin Orthop Relat Res       Date:  2016-07       Impact factor: 4.176

3.  A Novel In Vitro System for Comparative Analyses of Bone Cells and Bacteria under Electrical Stimulation.

Authors:  Thomas Josef Dauben; Josefin Ziebart; Thomas Bender; Sarah Zaatreh; Bernd Kreikemeyer; Rainer Bader
Journal:  Biomed Res Int       Date:  2016-12-04       Impact factor: 3.411

4.  Antibiotics Enhance Prevention and Eradication Efficacy of Cathodic-Voltage-Controlled Electrical Stimulation against Titanium-Associated Methicillin-Resistant Staphylococcus aureus and Pseudomonas aeruginosa Biofilms.

Authors:  Mary K Canty; Lisa A Hansen; Menachem Tobias; Sandy Spencer; Terry Henry; Nicole R Luke-Marshall; Anthony A Campagnari; Mark T Ehrensberger
Journal:  mSphere       Date:  2019-05-01       Impact factor: 4.389

5.  Ionic Silver and Electrical Treatment for Susceptibility and Disinfection of Escherichia coli Biofilm-Contaminated Titanium Surface.

Authors:  Kritphudis Suttasattakrit; Arnon Khamkeaw; Chanchana Tangwongsan; Prasit Pavasant; Muenduen Phisalaphong
Journal:  Molecules       Date:  2021-12-28       Impact factor: 4.411

Review 6.  Current treatments for biofilm-associated periprosthetic joint infection and new potential strategies.

Authors:  Anabelle Visperas; Daniel Santana; Alison K Klika; Carlos A Higuera-Rueda; Nicolas S Piuzzi
Journal:  J Orthop Res       Date:  2022-05-06       Impact factor: 3.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.