Literature DB >> 3379510

In vitro studies of fretting corrosion of orthopaedic materials.

S A Brown1, P J Hughes, K Merritt.   

Abstract

Two models were used to study fretting corrosion of surgical alloys. In the first, the amount of load and motion between plates and screws was controlled, and corrosion rates of stainless steel and MP35N were determined by measurements of component weight loss and metal ion concentration in the test solutions. Stainless steel had the higher rate of fretting corrosion. The addition of 10% serum to saline resulted in a significant reduction of the corrosion rate of stainless steel and MP35N. The use of stainless steel screws in a mixed-metal combination with MP35N and titanium plates showed minimal effects on the performance of the stainless steel screws but an increase in fretting corrosion of the MP35N plates. In the second model, plates were applied to glass fiber-reinforced plastic tubes as bone analogues and subjected to cyclic axial loads. These results demonstrated a reduction in fretting corrosion rates associated with an increase in screw torque and a decrease in axial load. Corrosion rates were minimal with intact tubes simulating healed fractures and greatest with an oblique-cut fracture simulation. These models have proven useful for the evaluation of fretting corrosion rates of different alloys and for evaluation of variables such as fracture stability.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3379510     DOI: 10.1002/jor.1100060415

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  8 in total

1.  Potentiodynamic Corrosion Testing.

Authors:  Selin Munir; Matthew H Pelletier; William R Walsh
Journal:  J Vis Exp       Date:  2016-09-04       Impact factor: 1.355

2.  Surface analysis of indigenous stainless steel miniplates used in facial fractures.

Authors:  Arun Dugal; Gagan Thakur
Journal:  J Maxillofac Oral Surg       Date:  2010-12-14

3.  In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants.

Authors:  Danieli C Rodrigues; Robert M Urban; Joshua J Jacobs; Jeremy L Gilbert
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-01       Impact factor: 3.368

4.  Fretting-corrosion in Hip Implant Modular Junctions: New Experimental Set-up and Initial Outcome.

Authors:  D Royhman; M Patel; M J Runa; J J Jacobs; N J Hallab; M A Wimmer; M T Mathew
Journal:  Tribol Int       Date:  2015-11-01       Impact factor: 4.872

Review 5.  Self-expanding nitinol stents: material and design considerations.

Authors:  Dieter Stoeckel; Alan Pelton; Tom Duerig
Journal:  Eur Radiol       Date:  2003-09-03       Impact factor: 5.315

6.  In vitro assessment of serum-saline ratios for fluid simulator testing of highly modular spinal implants with articulating surfaces.

Authors:  Nadim Hallab; Ashutosh Khandha; George Malcolmson; J P Timm
Journal:  SAS J       Date:  2008-12-01

7.  Fretting and Corrosion in Modular Shoulder Arthroplasty: A Retrieval Analysis.

Authors:  Johannes A Eckert; Ulrike Mueller; Sebastian Jaeger; Benjamin Panzram; J Philippe Kretzer
Journal:  Biomed Res Int       Date:  2016-06-28       Impact factor: 3.411

Review 8.  Local Cellular Responses to Titanium Dioxide from Orthopedic Implants.

Authors:  Jie J Yao; Eric A Lewallen; William H Trousdale; Wei Xu; Roman Thaler; Christopher G Salib; Nicolas Reina; Matthew P Abdel; David G Lewallen; Andre J van Wijnen
Journal:  Biores Open Access       Date:  2017-07-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.