Literature DB >> 12516082

In vitro corrosion testing of modular hip tapers.

Jay R Goldberg1, Jeremy L Gilbert.   

Abstract

The in vivo fretting behavior of modular hip prostheses was simulated to determine the effects of material combination and a unique TiN/AlN coating on fretting and corrosion at the taper interface. Fretting current, open-circuit potential (OCP), and quantities of soluble debris were measured to determine the role of mechanically assisted crevice corrosion on fretting and corrosion of modular hip tapers. Test groups consisting of similar-alloy (Co-Cr-Mo head/Co-Cr-Mo neck), mixed-alloy (Co-Cr-Mo head/Ti-6Al-4V neck), and TiN/AlN-coated mixed-alloy modular hip taper couples were used. Loads required to initiate fretting were similar for all test groups and were well below loads produced by walking and other physical activities. Decreases in OCP and increases in fretting current observed during long-term cyclic loading were indicative of fretting and corrosion. Current measured after cessation of cyclic loading suggests that once the conditions for crevice corrosion are established, corrosion can continue in the absence of loading. The chemical, mechanical, and electrochemical measurements, along with microscopic inspections of the taper surfaces indicate that the fretting and corrosion behavior of similar- and mixed-alloy taper couples are similar and that the coated samples are more resistant to fretting and corrosion. The results of this study clearly indicate the role of mechanical loading in the corrosion process, and support the hypothesis of mechanically assisted crevice corrosion. (c) 2002 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12516082     DOI: 10.1002/jbm.b.10526

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  39 in total

1.  Assessment of wear on the cones of modular stainless steel Exeter hip stems.

Authors:  R P S Chaplin; A J C Lee; R M Hooper
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

2.  Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study.

Authors:  Genymphas B Higgs; Josa A Hanzlik; Daniel W MacDonald; Jeremy L Gilbert; Clare M Rimnac; Steven M Kurtz
Journal:  J Arthroplasty       Date:  2013-08-01       Impact factor: 4.757

3.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

4.  Modern trunnions are more flexible: a mechanical analysis of THA taper designs.

Authors:  David A Porter; Robert M Urban; Joshua J Jacobs; Jeremy L Gilbert; José A Rodriguez; H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2014-09-30       Impact factor: 4.176

5.  The effect of manufacturing tolerances on the mechanical environment of taper junctions in modular TKR.

Authors:  Kyle Snethen; Jorge Hernandez; Melinda Harman
Journal:  J Mech Behav Biomed Mater       Date:  2019-04-18

Review 6.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

Review 7.  [Endoprostheses in the elderly : Biomaterials, implant selection and fixation technique].

Authors:  M M Morlock; M Jäger
Journal:  Orthopade       Date:  2017-01       Impact factor: 1.087

8.  Case reports: fractures of threaded cups: rare complications of a well-established implant.

Authors:  Arnd T Hoburg; Manav Mehta; Stephan Tohtz; Carsten Perka
Journal:  Clin Orthop Relat Res       Date:  2008-09-27       Impact factor: 4.176

9.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

10.  Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.

Authors:  Thomas M Grupp; Thomas Weik; Wilhelm Bloemer; Hanns-Peter Knaebel
Journal:  BMC Musculoskelet Disord       Date:  2010-01-04       Impact factor: 2.362

View more