Literature DB >> 18617101

Removal torque values of surface-treated mini-implants after loading.

Seong-Hun Kim1, Jae-Hee Cho, Kyu-Rhim Chung, Yoon-Ah Kook, Gerald Nelson.   

Abstract

INTRODUCTION: Although the sand-blasted, large-grit, and acid-etched surface-treated mini-implant (C-implant, CImplant Co, Seoul, South Korea) is designed to endure heavy and dynamic loads and offers high stability during orthodontic treatment, implications of its removal are still unknown. The purpose of this study was to evaluate the removal torque values (RTVs) of early-loaded mini-implants.
METHODS: Sixty-four mini-implants (1.8 mm in diameter and 8.5 mm in length) were placed in 37 patients for orthodontic anchorage and were subjected to early loading (4 weeks healing period). RTVs were recorded after orthodontic treatment by using a digital torque driver that was calibrated on a torque sensor. Torque values were subjected to a paired t test and analysis of variance (P <0.05).
RESULTS: All mini-implants remained intact, for a 100% success rate. There was no fracture or distortion during removal, and the mean RTV was 16.4 N per centimeter (range, 3.94-35.41 N per centimeter). Age, malocclusion, and loading period were not significantly related to the RTVs. The longer nonloading period from debonding to removal had a higher RTV. The RTV measured over 6 months of the nonloading period showed a significantly higher RTV than the group measured less than 6 months of the nonloading period.
CONCLUSIONS: Surface-treated mini-implants can be safely removed after treatment. A nonloading period of less than 6 months before removal is recommended to prevent complications.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18617101     DOI: 10.1016/j.ajodo.2006.07.038

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  19 in total

1.  Atomic layout of an orthodontic titanium mini-implant in human tissue: Insights into the possible mechanisms during osseointegration.

Authors:  Jun-Sik Kim; Jae-Pyeong Ahn; Yang-Hee Kim; Kyung Won Seo; Homayoun Zadeh; Seong-Hun Kim
Journal:  Angle Orthod       Date:  2018-11-28       Impact factor: 2.079

2.  Accuracy of torque-limiting devices for mini-implant removal: an in vitro study.

Authors:  A Pauls; M Nienkemper; D Drescher
Journal:  J Orofac Orthop       Date:  2013-05-08       Impact factor: 1.938

3.  Experimental investigation of the fracture torque of orthodontic anchorage screws.

Authors:  Susanne Reimann; Mustafa Ayubi; Fraser McDonald; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

4.  Accuracy of a cone beam computed tomography-guided surgical stent for orthodontic mini-implant placement.

Authors:  Jae-Jung Yu; Gyu-Tae Kim; Yong-Suk Choi; Eui-Hwan Hwang; Janghyun Paek; Seong-Hun Kim; John C Huang
Journal:  Angle Orthod       Date:  2011-08-29       Impact factor: 2.079

5.  Do sand blasted with large grit and acid etched surface treated mini-implants remain stationary under orthodontic forces?

Authors:  Seong-Hun Kim; Jeong-Ho Choi; Kyu-Rhim Chung; Gerald Nelson
Journal:  Angle Orthod       Date:  2011-08-10       Impact factor: 2.079

6.  Stability changes of miniscrew implants over time.

Authors:  Derid S Ure; Donald R Oliver; Ki Beom Kim; Ana Cláudia Melo; Peter H Buschang
Journal:  Angle Orthod       Date:  2011-05-25       Impact factor: 2.079

7.  Comparison between microporous and nanoporous orthodontic miniscrews : An experimental study in rabbits.

Authors:  Yueh-Tse Lee; Eric Jein-Wein Liou; Sinn-Wen Chen
Journal:  J Orofac Orthop       Date:  2022-05-20       Impact factor: 1.938

8.  Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy.

Authors:  Giselle Naback Lemes Vilani; Antônio Carlos de Oliveira Ruellas; Carlos Nelson Elias; Cláudia Trindade Mattos
Journal:  Dental Press J Orthod       Date:  2015-10

9.  Resistance to immediate orthodontic loading of surface-treated mini-implants.

Authors:  Sung-Seo Mo; Seong-Hun Kim; Yoon-Ah Kook; Do-Min Jeong; Kyu-Rhim Chung; Gerald Nelson
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

10.  Effect of surface treatment on the mechanical stability of orthodontic miniscrews.

Authors:  Yousef Al-Thomali; Sakeenabi Basha; Roshan Noor Mohamed
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.