Literature DB >> 18581419

Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent.

Elizabeth Bucholz1, Ketan Ghaghada, Yi Qi, Srinivasan Mukundan, G Allan Johnson.   

Abstract

Magnetic resonance microscopy (MRM) has become an important tool for small animal cardiac imaging. In relation to competing technologies (microCT and ultrasound), MR is limited by spatial resolution, temporal resolution, and acquisition time. All three of these limitations have been addressed by developing a four-dimensional (4D) (3D plus time) radial acquisition (RA) sequence. The signal-to-noise ratio (SNR) has been optimized by minimizing the echo time (TE) (300 us). The temporal resolution and throughput have been improved by center-out trajectories resulting in repetition time (TR) <2.5 ms. The contrast has been enhanced through the use of a liposomal blood pool agent that reduces the T(1) of the blood to <400 ms. We have developed protocols for three specific applications: 1) high-throughput with spatial resolution of 87 x 87 x 352 um(3) (voxel volume = 2.7 nL) and acquisition time of 16 min; 2) high-temporal resolution with spatial resolution of 87 x 87 x 352 um(3) (voxel volume = 2.7 nL) and temporal resolution at 4.8 ms and acquisition time of 32 minutes; and 3) high-resolution isotropic imaging at 87 x 87 x 87 um(3) (voxel volume = 0.68 nL) and acquisition time of 31 min. The 4D image arrays allow direct measure of cardiac functional parameters dependent on chamber volumes, e.g., ejection fraction (EF), end diastolic volume (EDV), and end systolic volume (ESV). (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18581419      PMCID: PMC2746046          DOI: 10.1002/mrm.21618

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  Three-dimensional cardiac cine magnetic resonance imaging with an ultrasmall superparamagnetic iron oxide blood pool agent (NC100150).

Authors:  Y Amano; R J Herfkens; R Y Shifrin; M T Alley; N J Pelc
Journal:  J Magn Reson Imaging       Date:  2000-02       Impact factor: 4.813

2.  Projection reconstruction techniques for reduction of motion effects in MRI.

Authors:  G H Glover; J M Pauly
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

3.  Comparison between prospective and retrospective triggering for mouse cardiac MRI.

Authors:  Edwin Heijman; Wolter de Graaf; Petra Niessen; Arno Nauerth; Guillaume van Eys; Larry de Graaf; Klaas Nicolay; Gustav J Strijkers
Journal:  NMR Biomed       Date:  2007-06       Impact factor: 4.044

4.  4D cardiac MRI in the mouse.

Authors:  Akiva Feintuch; Yonghong Zhu; Jonathan Bishop; Lorinda Davidson; Jun Dazai; Benoit G Bruneau; R Mark Henkelman
Journal:  NMR Biomed       Date:  2007-05       Impact factor: 4.044

5.  High temporal resolution breathheld 3D FIESTA CINE imaging: validation of ventricular function in patients with chronic myocardial infarction.

Authors:  Dan W Rettmann; Manojkumar Saranathan; Katherine C Wu; Clerio F Azevedo; David A Bluemke; Thomas K F Foo
Journal:  J Magn Reson Imaging       Date:  2007-06       Impact factor: 4.813

6.  Cardiac MRI in mice at 9.4 Tesla with a transmit-receive surface coil and a cardiac-tailored intensity-correction algorithm.

Authors:  David E Sosnovik; Guangping Dai; Matthias Nahrendorf; Bruce R Rosen; Ravi Seethamraju
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

7.  High-resolution vascular imaging of the rat spine using liposomal blood pool MR agent.

Authors:  K B Ghaghada; K H J Bockhorst; S Mukundan; A V Annapragada; P A Narayana
Journal:  AJNR Am J Neuroradiol       Date:  2007-01       Impact factor: 3.825

8.  Black blood gradient echo cine magnetic resonance imaging of the mouse heart.

Authors:  Stuart S Berr; Rene Jack Roy; Brent A French; Zequan Yang; Wesley Gilson; Christopher M Kramer; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2005-05       Impact factor: 4.668

9.  Magnetic resonance imaging of coronary arteries and heart valves in a living mouse: techniques and preliminary results.

Authors:  J Ruff; F Wiesmann; T Lanz; A Haase
Journal:  J Magn Reson       Date:  2000-10       Impact factor: 2.229

10.  High-resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic arch.

Authors:  Frank Wiesmann; Michael Szimtenings; Alex Frydrychowicz; Ralf Illinger; Andreas Hunecke; Eberhard Rommel; Stefan Neubauer; Axel Haase
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

View more
  17 in total

1.  Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats.

Authors:  Cristian T Badea; Laurence W Hedlund; James Cook; Brian R Berridge; G Allan Johnson
Journal:  J Pharmacol Toxicol Methods       Date:  2010-04-23       Impact factor: 1.950

2.  Cardiovascular phenotyping of the mouse heart using a 4D radial acquisition and liposomal Gd-DTPA-BMA.

Authors:  Elizabeth Bucholz; Ketan Ghaghada; Yi Qi; Srinivasan Mukundan; Howard A Rockman; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

3.  Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization.

Authors:  Darin Clark; Alexandra Badea; Yilin Liu; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-09-13       Impact factor: 3.609

4.  Morphological studies of the murine heart based on probabilistic and statistical atlases.

Authors:  Dimitrios Perperidis; Elizabeth Bucholz; G Allan Johnson; Christakis Constantinides
Journal:  Comput Med Imaging Graph       Date:  2011-08-05       Impact factor: 4.790

5.  4D micro-CT using fast prospective gating.

Authors:  Xiaolian Guo; Samuel M Johnston; Yi Qi; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-01-07       Impact factor: 3.609

Review 6.  Whole animal imaging.

Authors:  Gurpreet Singh Sandhu; Luis Solorio; Ann-Marie Broome; Nicolas Salem; Jeff Kolthammer; Tejas Shah; Chris Flask; Jeffrey L Duerk
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2010 Jul-Aug

7.  High-resolution magnetic resonance angiography in the mouse using a nanoparticle blood-pool contrast agent.

Authors:  Gabriel P Howles; Ketan B Ghaghada; Yi Qi; Srinivasan Mukundan; G Allan Johnson
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

8.  Accelerated cardiovascular magnetic resonance of the mouse heart using self-gated parallel imaging strategies does not compromise accuracy of structural and functional measures.

Authors:  David Ratering; Christof Baltes; Carola Dörries; Markus Rudin
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-21       Impact factor: 5.364

9.  INTERCOMPARISON OF PERFORMANCE OF RF COIL GEOMETRIES FOR HIGH FIELD MOUSE CARDIAC MRI.

Authors:  Christakis Constantinides; S Angeli; S Gkagkarellis; G Cofer
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2011-09       Impact factor: 0.481

10.  New dual mode gadolinium nanoparticle contrast agent for magnetic resonance imaging.

Authors:  Ketan B Ghaghada; Murali Ravoori; Divya Sabapathy; James Bankson; Vikas Kundra; Ananth Annapragada
Journal:  PLoS One       Date:  2009-10-29       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.