Literature DB >> 10713938

Three-dimensional cardiac cine magnetic resonance imaging with an ultrasmall superparamagnetic iron oxide blood pool agent (NC100150).

Y Amano1, R J Herfkens, R Y Shifrin, M T Alley, N J Pelc.   

Abstract

The purpose of this study was to assess image quality of three-dimensional (3D) cardiac cine magnetic resonance (MR) imaging before and after administration of a T1-shortening ultrasmall superparamagnetic iron oxide blood pool agent (NC100150). 3D cardiac cine MR imaging was performed in 13 volunteers using a radiofrequency-spoiled cardiac-gated 3D cine gradient-echo sequence with short repetition and echo times. Compared with precontrast images, postcontrast images showed no enhancement in fat and skeletal muscle, moderate enhancement in myocardium, and significant enhancement in ventricular cavity. After contrast injection, the signal ratio of the ventricular chamber to the myocardium significantly increased, and dramatic improvements were seen in the quality of the cineangiographic images and the depiction of cardiac valves. This quantitative study has shown that 3D cardiac cine MR imaging using a blood pool agent provided MR ventriculography and cineangiography with excellent image quality.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10713938     DOI: 10.1002/(sici)1522-2586(200002)11:2<81::aid-jmri2>3.0.co;2-n

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  Cardiovascular phenotyping of the mouse heart using a 4D radial acquisition and liposomal Gd-DTPA-BMA.

Authors:  Elizabeth Bucholz; Ketan Ghaghada; Yi Qi; Srinivasan Mukundan; Howard A Rockman; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

2.  Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent.

Authors:  Elizabeth Bucholz; Ketan Ghaghada; Yi Qi; Srinivasan Mukundan; G Allan Johnson
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

3.  Single-Breathhold Four-Dimensional Assessment of Left Ventricular Morphological and Functional Parameters by Magnetic Resonance Imaging Using the VAST Technique.

Authors:  Carlos Eduardo Rochitte; Clerio F Azevedo; Miguel A Rosário; Maria H R Siqueira; Victor Monsão; Manoj Saranathan; Thomas K Foo; Roberto Kalil Filho; Giovanni G Cerri; José A F Ramires
Journal:  Open Cardiovasc Med J       Date:  2011-03-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.