Literature DB >> 17120296

Comparison between prospective and retrospective triggering for mouse cardiac MRI.

Edwin Heijman1, Wolter de Graaf, Petra Niessen, Arno Nauerth, Guillaume van Eys, Larry de Graaf, Klaas Nicolay, Gustav J Strijkers.   

Abstract

High-resolution magnetic resonance imaging (MRI) has evolved into one of the major non-invasive tools to study the healthy and diseased mouse heart. This study presents a Cartesian CINE MRI protocol based on a fast low-angle shot sequence with a navigator echo to generate cardiac triggering and respiratory gating signals retrospectively, making the use of ECG leads and respiratory motion sensors obsolete. MRI of the in vivo mouse heart using this sequence resulted in CINE images with no detectable cardiac and respiratory motion artefacts. The retrospective method allows for steady-state imaging of the mouse heart, which is essential for quantitative contrast-enhanced MRI studies. A comparison was made between prospective and retrospective methods in terms of the signal-to-noise ratio and the contrast-to-noise ratio between blood and myocardial wall, as well as global cardiac functional indices: end-diastolic volume, end-systolic volume, stroke volume and ejection fraction. The retrospective method resulted in almost constant left-ventricle wall signal intensity throughout the cardiac cycle, at the expense of a decrease in the signal-to-noise ratio and the contrast-to-noise ratio between blood and myocardial wall as compared with the prospective method. Prospective and retrospective sequences yielded comparable global cardiac functional indices. The largest mean relative difference found was 8% for the end-systolic volume. (c) 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2007        PMID: 17120296     DOI: 10.1002/nbm.1110

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  31 in total

1.  Paigen diet-fed apolipoprotein E knockout mice develop severe pulmonary hypertension in an interleukin-1-dependent manner.

Authors:  Allan Lawrie; Abdul G Hameed; Janet Chamberlain; Nadine Arnold; Aneurin Kennerley; Kay Hopkinson; Josephine Pickworth; David G Kiely; David C Crossman; Sheila E Francis
Journal:  Am J Pathol       Date:  2011-08-09       Impact factor: 4.307

2.  Functional imaging of murine hearts using accelerated self-gated UTE cine MRI.

Authors:  Abdallah G Motaal; Nils Noorman; Wolter L de Graaf; Verena Hoerr; Luc M J Florack; Klaas Nicolay; Gustav J Strijkers
Journal:  Int J Cardiovasc Imaging       Date:  2014-09-10       Impact factor: 2.357

3.  In Vivo Evaluation of Magnetic Targeting in Mice Colon Tumors with Ultra-Magnetic Liposomes Monitored by MRI.

Authors:  Caroline J Thébault; Grégory Ramniceanu; Aude Michel; Claire Beauvineau; Christian Girard; Johanne Seguin; Nathalie Mignet; Christine Ménager; Bich-Thuy Doan
Journal:  Mol Imaging Biol       Date:  2019-04       Impact factor: 3.488

4.  Longitudinal free-breathing MRI measurement of murine lung physiology in a progressive model of lung fibrosis.

Authors:  Jinbang Guo; William D Hardie; Zackary I Cleveland; Cynthia Davidson; Xuefeng Xu; Satish K Madala; Jason C Woods
Journal:  J Appl Physiol (1985)       Date:  2019-02-07

5.  Single-Breath-Hold Evaluation of Cardiac Function with Use of Time-Resolved Parallel Cardiac Magnetic Resonance.

Authors:  Patrick Krumm; Jonas D Keuler; Stefanie Mangold; Tanja Zitzelsberger; Christer A Ruff; Bernhard D Klumpp; Petros Martirosian; Konstantin Nikolaou; Christof Burgstahler; Ulrich Kramer
Journal:  Tex Heart Inst J       Date:  2017-08-01

6.  Monitoring infection and inflammation in murine models of cystic fibrosis with magnetic resonance imaging.

Authors:  Vipul R Sheth; R Christiaan van Heeckeren; Alma G Wilson; Anna M van Heeckeren; Mark D Pagel
Journal:  J Magn Reson Imaging       Date:  2008-08       Impact factor: 4.813

7.  Accelerated cardiovascular magnetic resonance of the mouse heart using self-gated parallel imaging strategies does not compromise accuracy of structural and functional measures.

Authors:  David Ratering; Christof Baltes; Carola Dörries; Markus Rudin
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-21       Impact factor: 5.364

8.  Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent.

Authors:  Elizabeth Bucholz; Ketan Ghaghada; Yi Qi; Srinivasan Mukundan; G Allan Johnson
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

9.  MR relaxometry and perfusion of the myocardium in spontaneously hypertensive rat: correlation with histopathology and effect of anti-hypertensive therapy.

Authors:  Jérôme Caudron; Paul Mulder; Lionel Nicol; Vincent Richard; Christian Thuillez; Jean-Nicolas Dacher
Journal:  Eur Radiol       Date:  2013-04-17       Impact factor: 5.315

10.  Prospective ECG-gated mouse cardiac imaging with a 34-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-07       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.