4D micro-CT using fast prospective gating.

Xiaolian Guo1, Samuel M Johnston, Yi Qi, G Allan Johnson, Cristian T Badea.   

Abstract

Micro-CT is currently used in preclinical studies to provide anatomical information. But, there is also significant interest in using this technology to obtain functional information. We report here a new sampling strategy for 4D micro-CT for functional cardiac and pulmonary imaging. Rapid scanning of free-breathing mice is achieved with fast prospective gating (FPG) implemented on a field programmable gate array. The method entails on-the-fly computation of delays from the R peaks of the ECG signals or the peaks of the respiratory signals for the triggering pulses. Projection images are acquired for all cardiac or respiratory phases at each angle before rotating to the next angle. FPG can deliver the faster scan time of retrospective gating (RG) with the regular angular distribution of conventional prospective gating for cardiac or respiratory gating. Simultaneous cardio-respiratory gating is also possible with FPG in a hybrid retrospective/prospective approach. We have performed phantom experiments to validate the new sampling protocol and compared the results from FPG and RG in cardiac imaging of a mouse. Additionally, we have evaluated the utility of incorporating respiratory information in 4D cardiac micro-CT studies with FPG. A dual-source micro-CT system was used for image acquisition with pulsed x-ray exposures (80 kVp, 100 mA, 10 ms). The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent containing 123 mg I ml(-1) delivered via a tail vein catheter in a dose of 0.01 ml g(-1) body weight. The phantom experiment demonstrates that FPG can distinguish the successive phases of phantom motion with minimal motion blur, and the animal study demonstrates that respiratory FPG can distinguish inspiration and expiration. 4D cardiac micro-CT imaging with FPG provides image quality superior to RG at an isotropic voxel size of 88 μm and 10 ms temporal resolution. The acquisition time for either sampling approach is less than 5 min. The radiation dose associated with the proposed method is in the range of a typical micro-CT dose (256 mGy for the cardiac study). Ignoring respiration does not significantly affect anatomic information in cardiac studies. FPG can deliver short scan times with low-dose 4D micro-CT imaging without sacrificing image quality. FPG can be applied in high-throughput longitudinal studies in a wide range of applications, including drug safety and cardiopulmonary phenotyping.

Entities:  

Mesh:

Year:  2012        PMID: 22156062      PMCID: PMC3388603          DOI: 10.1088/0031-9155/57/1/257

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm.

Authors:  C Kamphuis; F J Beekman
Journal:  IEEE Trans Med Imaging       Date:  1998-12       Impact factor: 10.048

2.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

3.  Left ventricle volume measurements in cardiac micro-CT: the impact of radiation dose and contrast agent.

Authors:  Cristian T Badea; Arthur W Wetzel; Nilesh Mistry; Stuart Pomerantz; Demian Nave; G Allan Johnson
Journal:  Comput Med Imaging Graph       Date:  2008-04       Impact factor: 4.790

4.  Convergence of EM image reconstruction algorithms with Gibbs smoothing.

Authors:  K Lange
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

5.  Micro-CT with respiratory and cardiac gating.

Authors:  C Badea; L W Hedlund; G A Johnson
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

6.  Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals.

Authors:  Stefan Sawall; Frank Bergner; Robert Lapp; Markus Mronz; Marek Karolczak; Andreas Hess; Marc Kachelriess
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

8.  Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent.

Authors:  Elizabeth Bucholz; Ketan Ghaghada; Yi Qi; Srinivasan Mukundan; G Allan Johnson
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

9.  A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating.

Authors:  Cristian T Badea; Eduard Schreibmann; Tim Fox
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

10.  Streaking artifacts reduction in four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Joseph Zambelli; Ranjini Tolakanahalli; Brian Nett; Peter Munro; Joshua Star-Lack; Bhudatt Paliwal; Guang-Hong Chen
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

View more
  9 in total

1.  Lung imaging in rodents using dual energy micro-CT.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C Marshall; C Piantadosi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-04-03

2.  Dual-energy micro-CT of the rodent lung.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C D Marshall; C A Piantadosi
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2012-03-16       Impact factor: 5.464

3.  Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

Authors:  M Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2018-01-09       Impact factor: 3.609

Review 4.  Approaches to Evaluate Lung Inflammation in Translational Research.

Authors:  David K Meyerholz; Jessica C Sieren; Amanda P Beck; Heather A Flaherty
Journal:  Vet Pathol       Date:  2017-08-16       Impact factor: 2.221

5.  Spectrotemporal CT data acquisition and reconstruction at low dose.

Authors:  Darin P Clark; Chang-Lung Lee; David G Kirsch; Cristian T Badea
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

6.  Cancer Patient-Derived Circulating Microparticles Enhance Lung Metastasis in a Rat Model: Dual-Source CT, Cellular, and Molecular Studies.

Authors:  Sheung-Fat Ko; Hon-Kan Yip; Yen-Yi Zhen; Chia-Chang Lee; Jung-Hui Li; Chen-Chang Lee; Steve Leu; Chung-Cheng Huang; Shu-Hang Ng; Jui-Wei Lin
Journal:  Mol Imaging Biol       Date:  2016-08       Impact factor: 3.488

7.  Coronary micro-computed tomography angiography in mice.

Authors:  Stefan Sawall; Jan Beckendorf; Carlo Amato; Joscha Maier; Johannes Backs; Greetje Vande Velde; Marc Kachelrieß; Jan Kuntz
Journal:  Sci Rep       Date:  2020-10-08       Impact factor: 4.379

Review 8.  In vivo small animal micro-CT using nanoparticle contrast agents.

Authors:  Jeffrey R Ashton; Jennifer L West; Cristian T Badea
Journal:  Front Pharmacol       Date:  2015-11-04       Impact factor: 5.810

9.  A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

Authors:  Cristian T Badea; Laurence W Hedlund; G Allan Johnson
Journal:  J Med Eng       Date:  2013-02-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.