Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems.

M Lamey1, J Yun, B Burke, S Rathee, B G Fallone.   

Abstract

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a multileaf collimator (MLC) for intensity-modulated radiotherapy for linac-MR units must be investigated. The MLC itself will likely reside in the fringe field of the MR and the motors will produce radio frequency (RF) noise. The RF noise power spectral density from a Varian 52-leaf MLC motor, a Varian Millennium MLC motor and a brushless fan motor has been measured as a function of the applied magnetic field using a near field probe set. For the Varian 52-leaf MLC system, the RF noise produced by 13 of 52 motors is studied as a function of distance from the MLC. Data are reported in the frequency range suitable for 0.2-1.5 T linac-MR systems. Below 40 MHz the Millennium MLC motor tested showed more noise than the Varian 52-leaf motor or the brushless fan motor. The brushless motor showed a small dependence on the applied magnetic field. Images of a phantom were taken by the prototype linac-MR system with the MLC placed in close proximity to the magnet. Several orientations of the MLC in both shielded and non-shielded configurations were studied. For the case of a non-shielded MLC and associated cables, the signal-to-noise ratio (SNR) was reduced when 13 of 52 MLC leaves were moved during imaging. When the MLC and associated cables were shielded, the measured SNR of the images with 13 MLC leaves moving was experimentally the same as the SNR of the stationary MLC image. When the MLC and cables are shielded, subtraction images acquired with and without MLC motion contains no systematic signal. This study illustrates that the small RF noise produced by functioning MLC motors can be effectively shielded to avoid SNR degradation. A functioning MLC can be incorporated into a linac-MR unit.

Mesh:

Year:  2010        PMID: 20090187      PMCID: PMC2910753          DOI: 10.1088/0031-9155/55/4/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

Review 1.  Organ motion and its management.

Authors:  K M Langen; D T Jones
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-05-01       Impact factor: 7.038

Review 2.  IMRT: a review and preview.

Authors:  Thomas Bortfeld
Journal:  Phys Med Biol       Date:  2006-06-20       Impact factor: 3.609

Review 3.  Motion effects in (intensity modulated) radiation therapy: a review.

Authors:  S Webb
Journal:  Phys Med Biol       Date:  2006-06-20       Impact factor: 3.609

4.  The effect on IMRT conformality of elastic tissue movement and a practical suggestion for movement compensation via the modified dynamic multileaf collimator (dMLC) technique.

Authors:  S Webb
Journal:  Phys Med Biol       Date:  2005-03-02       Impact factor: 3.609

5.  A (short) history of image-guided radiotherapy.

Authors:  Dirk Verellen; Mark De Ridder; Guy Storme
Journal:  Radiother Oncol       Date:  2008-01       Impact factor: 6.280

6.  MRI/linac integration.

Authors:  Jan J W Lagendijk; Bas W Raaymakers; Alexander J E Raaijmakers; Johan Overweg; Kevin J Brown; Ellen M Kerkhof; Richard W van der Put; Björn Hårdemark; Marco van Vulpen; Uulke A van der Heide
Journal:  Radiother Oncol       Date:  2007-11-26       Impact factor: 6.280

7.  A new way of adapting IMRT delivery fraction-by-fraction to cater for variable intrafraction motion.

Authors:  S Webb; T Bortfeld
Journal:  Phys Med Biol       Date:  2008-08-26       Impact factor: 3.609

8.  Moving targets: detection and tracking of internal organ motion for treatment planning and patient set-up.

Authors:  Eike Rietzel; Stanley J Rosenthal; David P Gierga; Christopher G Willet; George T Y Chen
Journal:  Radiother Oncol       Date:  2004-12       Impact factor: 6.280

9.  Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Authors:  Amit Sawant; Raghu Venkat; Vikram Srivastava; David Carlson; Sergey Povzner; Herb Cattell; Paul Keall
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

10.  Patient dosimetry for hybrid MRI-radiotherapy systems.

Authors:  C Kirkby; T Stanescu; S Rathee; M Carlone; B Murray; B G Fallone
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

View more
  1 in total

1.  Glamour of technology.

Authors:  Bhudatt R Paliwal
Journal:  J Med Phys       Date:  2010-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.