Literature DB >> 18561676

The performance of interventional loopless MRI antennae at higher magnetic field strengths.

AbdEl-Monem M El-Sharkawy1, Di Qian, Paul A Bottomley.   

Abstract

Interventional, "loopless antenna" MRI detectors are currently limited to 1.5 T. This study investigates whether loopless antennae offer signal-to-noise ratio (SNR) and field-of-view (FOV) advantages at higher fields, and whether device heating can be controlled within safe limits. The absolute SNR performance of loopless antennae from 0.5 to 5 T is investigated both analytically, using electromagnetic (EM) dipole antenna theory, and numerically with the EM method of moments, and found to vary almost quadratically with field strength depending on the medium's electrical properties, the noise being dominated by direct sample conduction losses. The prediction is confirmed by measurements of the absolute SNR of low-loss loopless antennae fabricated for 1.5, 3, and 4.7 T, immersed in physiologically comparable saline. Gains of 3.8 +/- 0.2- and 9.7 +/- 0.3-fold in SNR, and approximately 10- and 50-fold gains in the useful FOV area are observed at 3 and 4.7 T, respectively, compared to 1.5 T. Heat testing of a 3 T biocompatible nitinol-antenna fabricated with a redesigned decoupling circuit shows maximum heating of approximately 1 degrees C for MRI operating at high MRI exposure levels. Experiments in the rabbit aorta confirm the SNR and FOV advantages of the 3 T antenna versus an equivalent commercial 1.5 T device in vivo. This work is the first to study the performance of experimental internal MRI detectors above 1.5 T. The large SNR and FOV gains realized present a major opportunity for high-resolution imaging of vascular pathology and MRI-guided intervention.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18561676      PMCID: PMC2669652          DOI: 10.1118/1.2905027

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Endourethral MRI.

Authors:  H H Quick; J M Serfaty; H K Pannu; R Genadry; C J Yeung; E Atalar
Journal:  Magn Reson Med       Date:  2001-01       Impact factor: 4.668

2.  Microimaging of atherosclerotic plaque in animal models.

Authors:  L Chaabane; E Canet; J M Serfaty; F Contard; D Guerrier; P Douek; A Briguet
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

3.  Intravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: feasibility study in rabbits.

Authors:  X Yang; E Atalar
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

4.  Toward MRI-guided coronary catheterization: visualization of guiding catheters, guidewires, and anatomy in real time.

Authors:  J M Serfaty; X Yang; P Aksit; H H Quick; M Solaiyappan; E Atalar
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

5.  RF safety of wires in interventional MRI: using a safety index.

Authors:  Christopher J Yeung; Robert C Susil; Ergin Atalar
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

6.  A Green's function approach to local rf heating in interventional MRI.

Authors:  C J Yeung; E Atalar
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

7.  In vivo real-time intravascular MRI.

Authors:  Pedro A Rivas; Krishna S Nayak; Greig C Scott; Michael V McConnell; Adam B Kerr; Dwight G Nishimura; John M Pauly; Bob S Hu
Journal:  J Cardiovasc Magn Reson       Date:  2002       Impact factor: 5.364

8.  A prototype RF dosimeter for independent measurement of the average specific absorption rate (SAR) during MRI.

Authors:  John P Stralka; Paul A Bottomley
Journal:  J Magn Reson Imaging       Date:  2007-11       Impact factor: 4.813

9.  Magnetically-assisted remote control (MARC) steering of endovascular catheters for interventional MRI: a model for deflection and design implications.

Authors:  Fabio Settecase; Marshall S Sussman; Mark W Wilson; Steven Hetts; Ronald L Arenson; Vincent Malba; Anthony F Bernhardt; Walter Kucharczyk; Timothy P L Roberts
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

10.  Transesophageal magnetic resonance imaging of the aortic arch and descending thoracic aorta in patients with aortic atherosclerosis.

Authors:  K A Shunk; J Garot; E Atalar; J A Lima
Journal:  J Am Coll Cardiol       Date:  2001-06-15       Impact factor: 24.094

View more
  24 in total

1.  Interventional loopless antenna at 7 T.

Authors:  Mehmet Arcan Ertürk; Abdel-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  Towards real-time intravascular endoscopic magnetic resonance imaging.

Authors:  Shashank Sathyanarayana; Michael Schär; Dara L Kraitchman; Paul A Bottomley
Journal:  JACC Cardiovasc Imaging       Date:  2010-11

3.  MRI endoscopy using intrinsically localized probes.

Authors:  Shashank Sathyanarayana; Paul A Bottomley
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

4.  A multichannel, real-time MRI RF power monitor for independent SAR determination.

Authors:  Abdel-Monem M El-Sharkawy; Di Qian; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

5.  The Interventional Loopless Antenna at 7 Tesla.

Authors:  Mehmet Arcan Erturk; AbdEl-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2012

6.  Monitoring local heating around an interventional MRI antenna with RF radiometry.

Authors:  M Arcan Ertürk; AbdEl-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

7.  Unexpected Heating of MR-compatible Cyroablation Probes Using a Conventional 1.5T MR Scanner.

Authors:  Dara L Kraitchman; Di Qian; Paul A Bottomley; Clifford R Weiss
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2012

8.  An RF dosimeter for independent SAR measurement in MRI scanners.

Authors:  Di Qian; Abdel-Monem M El-Sharkawy; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

9.  A combined interventional high-resolution targeted ablation, thermometry and imaging probe.

Authors:  M Arcan Erturk; Shashank Sathyanarayana Hegde; Paul A Bottomley
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2015 May-Jun

10.  Automated classification of vessel disease based on high-resolution intravascular multi-parametric mapping MRI.

Authors:  Guan Wang; M Arcan Erturk; Shashank Sathyanarayana Hegde; Paul A Bottomley
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2015 May-Jun
View more