A Green's function approach to local rf heating in interventional MRI.

C J Yeung1, E Atalar.   

Abstract

Current safety regulations for local radiofrequency (rf) heating, developed for externally positioned rf coils, may not be suitable for internal rf coils that are being increasingly used in interventional MRI. This work presents a two-step model for rf heating in an interventional MRI setting: (1) the spatial distribution of power in the sample from the rf pulse (Maxwell's equations); and (2) the transformation of that power to temperature change according to thermal conduction and tissue perfusion (tissue bioheat equation). The tissue bioheat equation is approximated as a linear, shift-invariant system in the case of local rf heating and is fully characterized by its Green's function. Expected temperature distributions are calculated by convolving (averaging) transmit coil specific absorption rate (SAR) distributions with the Green's function. When the input SAR distribution is relatively slowly varying in space, as is the case with excitation by external rf coils, the choice of averaging methods makes virtually no difference on the expected heating as measured by temperature change (deltaT). However, for highly localized SAR distributions, such as those encountered with internal coils in interventional MRI, the Green's function method predicts heating that is significantly different from the averaging method in current regulations. In our opinion, the Green's function method is a better predictor since it is based on a physiological model. The Green's function also elicits a time constant and scaling factor between SAR and deltaT that are both functions of the tissue perfusion rate. This emphasizes the critical importance of perfusion in the heating model. The assumptions made in this model are only valid for local rf heating and should not be applied to whole body heating.

Mesh:

Year:  2001        PMID: 11393478     DOI: 10.1118/1.1367860

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Thermal safety of vibro-acoustography using a confocal transducer.

Authors:  Shigao Chen; Wilkins Aquino; Azra Alizad; Matthew W Urban; Randall Kinnick; James F Greenleaf; Mostafa Fatemi
Journal:  Ultrasound Med Biol       Date:  2010-02       Impact factor: 2.998

Review 2.  Interventional and intraoperative MR: review and update of techniques and clinical experience.

Authors:  Thomas Schulz; Silvia Puccini; Jens-Peter Schneider; Thomas Kahn
Journal:  Eur Radiol       Date:  2004-10-06       Impact factor: 5.315

Review 3.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

4.  The performance of interventional loopless MRI antennae at higher magnetic field strengths.

Authors:  AbdEl-Monem M El-Sharkawy; Di Qian; Paul A Bottomley
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

5.  Using a low-amplitude RF pulse at echo time (LARFET) for device localization in MRI.

Authors:  Murat Tümer; Baykal Sarioglu; Senol Mutlu; Yekta Ulgen; Arda Yalcinkaya; Cengizhan Ozturk
Journal:  Med Biol Eng Comput       Date:  2014-08-31       Impact factor: 2.602

6.  Parallel transmit pulse design for patients with deep brain stimulation implants.

Authors:  Yigitcan Eryaman; Bastien Guerin; Can Akgun; Joaquin L Herraiz; Adrian Martin; Angel Torrado-Carvajal; Norberto Malpica; Juan A Hernandez-Tamames; Emanuele Schiavi; Elfar Adalsteinsson; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-06-19       Impact factor: 4.668

7.  Parallel transmission to reduce absorbed power around deep brain stimulation devices in MRI: Impact of number and arrangement of transmit channels.

Authors:  Bastien Guerin; Leonardo M Angelone; Darin Dougherty; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-08-07       Impact factor: 4.668

8.  Realistic modeling of deep brain stimulation implants for electromagnetic MRI safety studies.

Authors:  Bastien Guerin; Peter Serano; Maria Ida Iacono; Todd M Herrington; Alik S Widge; Darin D Dougherty; Giorgio Bonmassar; Leonardo M Angelone; Lawrence L Wald
Journal:  Phys Med Biol       Date:  2018-05-04       Impact factor: 3.609

9.  Thermal modeling of lesion growth with radiofrequency ablation devices.

Authors:  Isaac A Chang; Uyen D Nguyen
Journal:  Biomed Eng Online       Date:  2004-08-06       Impact factor: 2.819

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.