Literature DB >> 11146495

Endourethral MRI.

H H Quick1, J M Serfaty, H K Pannu, R Genadry, C J Yeung, E Atalar.   

Abstract

Although high-resolution MRI with phased array pelvic, endorectal, and endovaginal coils has dramatically enhanced the ability to visualize abnormalities of the female urethra and periurethral tissues, controversy still remains about the anatomy of this region. This study introduces an endourethral approach for ultra-high-resolution MRI of the female urethra and the periurethral tissues. To this end, two different radiofrequency (RF) receiver coil designs for an endourethral insertion have been developed: a single-loop coil and a phased array/quadrature coil. Both designs feature a flexible coil circuit, small loss tuning and matching directly at the coil, active decoupling, and the integration of a lambda/4 coaxial choke to decrease unbalanced currents and limit potential RF heating effects. Effective reduction of the mutual inductance between the two coils of the phased array design was achieved by introducing a metallic "paddle" to steer the flux between the coils. The performance of the coils has been evaluated in female human cadaver studies and in an in vivo pig experiment. The novel endourethral approach enabled a dramatic increase of the signal-to-noise ratio (SNR) at the region of interest (ROI). High-resolution MR images of the female urethra have been acquired with a spatial resolution down to 78 x 78 microm. Histologic correlation was achieved for the MR images generated. The achieved high local SNR and resulting high spatial resolution will add valuable information to the discussion of female urethral anatomy. Magn Reson Med 45:138-146, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11146495     DOI: 10.1002/1522-2594(200101)45:1<138::aid-mrm1018>3.0.co;2-g

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  The axial location of structural regions in the urethra: a magnetic resonance study in nulliparous women.

Authors:  Wolfgang H Umek; Rohna Kearney; Daniel M Morgan; James A Ashton-Miller; John O L DeLancey
Journal:  Obstet Gynecol       Date:  2003-11       Impact factor: 7.661

Review 2.  MRI of pelvic organ prolapse.

Authors:  Harpreet K Pannu
Journal:  Eur Radiol       Date:  2004-03-26       Impact factor: 5.315

3.  An MRI-compatible robotic system with hybrid tracking for MRI-guided prostate intervention.

Authors:  Axel Krieger; Iulian I Iordachita; Peter Guion; Anurag K Singh; Aradhana Kaushal; Cynthia Ménard; Peter A Pinto; Kevin Camphausen; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2011-11       Impact factor: 4.538

Review 4.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

5.  Design of internal MRI coils using ultimate intrinsic SNR.

Authors:  Yiğitcan Eryaman; Yusuf Oner; Ergin Atalar
Journal:  MAGMA       Date:  2009-03-27       Impact factor: 2.310

6.  The performance of interventional loopless MRI antennae at higher magnetic field strengths.

Authors:  AbdEl-Monem M El-Sharkawy; Di Qian; Paul A Bottomley
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

7.  Actively Decoupled Transmit-Receive Coil-Pair for Mouse Brain MRI.

Authors:  Joel R Garbow; Charlie McIntosh; Mark S Conradi
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2008-10       Impact factor: 1.176

8.  Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention.

Authors:  Axel Krieger; Sang-Eun Song; Nathan B Cho; Iulian Iordachita; Peter Guion; Gabor Fichtinger; Louis L Whitcomb
Journal:  IEEE ASME Trans Mechatron       Date:  2011-10-17       Impact factor: 5.303

9.  Shape analysis of the prostate: establishing imaging specifications for the design of a transurethral imaging device for prostate brachytherapy guidance.

Authors:  David R Holmes; Brian J Davis; Christopher C Goulet; Torrence M Wilson; Lance A Mynderse; Keith M Furutani; Jon J Camp; Richard A Robb
Journal:  Brachytherapy       Date:  2014-06-21       Impact factor: 2.362

10.  Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes.

Authors:  Ozgur Kocaturk; Christina E Saikus; Michael A Guttman; Anthony Z Faranesh; Kanishka Ratnayaka; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2009-08-12       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.