Analysis of different bicruciate-retaining tibial prosthesis design using a three dimension finite element model.

Peiheng He1, Xing Li1, Shuai Huang1, Minghao Liu1, Weizhi Chen1, Dongliang Xu1.   

Abstract

The recent interest in bicruciate-retaining prostheses has aimed to address the need for an implant that can mimic a natural knee. Arguments have always existed about survivorship, including loosening and subsidence, as well as tibial preparation in bicruciate-retaining tibial prostheses. The aim of this study was to investigate the biomechanics of a new modular design and other bicruciate-retaining designs using a three-dimensional finite element model under different load conditions to discover which prosthesis was more suitable. We also evaluated related parameters (the third principal stress, shear stress, micromotion, and von Mises stresses) to compare the characteristics of different bicruciate-retaining designs. The biomechanics of the bicruciate-retaining tibial prosthesis can be influenced by the style of the designed prosthesis and gait loading. The new modular design showed stability and moderated the third principal stress, leading to less shear stress and stress shield, suggesting that this type of design can avoid knee prosthesis loosening and subsidence. Therefore, the new design may be used as a more suitable prosthesis for future bicruciate-retaining implant application.

Entities:  

Keywords:  Bicruciate-retaining tibial prosthesis; biomechanics; loosening; new modular design; subsidence; three dimensional finite element model

Year:  2017        PMID: 28560009      PMCID: PMC5446541     

Source DB:  PubMed          Journal:  Am J Transl Res        ISSN: 1943-8141            Impact factor:   4.060


  40 in total

1.  Experimental and biphasic FEM determinations of the material properties and hydraulic permeability of the meniscus in tension.

Authors:  Michelle A LeRoux; Lori A Setton
Journal:  J Biomech Eng       Date:  2002-06       Impact factor: 2.097

2.  A large scale finite element study of a cementless osseointegrated tibial tray.

Authors:  Francis Galloway; Max Kahnt; Heiko Ramm; Peter Worsley; Stefan Zachow; Prasanth Nair; Mark Taylor
Journal:  J Biomech       Date:  2013-06-10       Impact factor: 2.712

3.  Hydroxyapatite-coated collars reduce radiolucent line progression in cemented distal femoral bone tumor implants.

Authors:  Melanie J Coathup; Anish Sanghrajka; William J Aston; Panagiotis D Gikas; Robin C Pollock; Stephen R Cannon; John A Skinner; Timothy W R Briggs; Gordon W Blunn
Journal:  Clin Orthop Relat Res       Date:  2015-01-30       Impact factor: 4.176

Review 4.  Bicruciate retaining arthroplasty.

Authors:  Michael A Mont; Mario John; Aaron Johnson
Journal:  Surg Technol Int       Date:  2012-12

5.  The influence of total knee arthroplasty geometry on mid-flexion stability: an experimental and finite element study.

Authors:  Chadd W Clary; Clare K Fitzpatrick; Lorin P Maletsky; Paul J Rullkoetter
Journal:  J Biomech       Date:  2013-03-15       Impact factor: 2.712

6.  What functional activities are important to patients with knee replacements?

Authors:  Jennifer M Weiss; Philip C Noble; Michael A Conditt; Harold W Kohl; Seth Roberts; Karon F Cook; Michael J Gordon; Kenneth B Mathis
Journal:  Clin Orthop Relat Res       Date:  2002-11       Impact factor: 4.176

7.  Effect of retaining a patellar prosthesis on pain, functional, and satisfaction outcomes after revision total knee arthroplasty.

Authors:  Bassam A Masri; R M Dominic Meek; Nelson V Greidanus; Donald S Garbuz
Journal:  J Arthroplasty       Date:  2006-12       Impact factor: 4.757

8.  Patient preferences in knee prostheses.

Authors:  J W Pritchett
Journal:  J Bone Joint Surg Br       Date:  2004-09

9.  A comparison of the noise generated from different types of knee prostheses.

Authors:  James W Pritchett
Journal:  J Knee Surg       Date:  2012-07-13       Impact factor: 2.757

10.  A combined RSA and FE study of the implanted proximal tibia: correlation of the post-operative mechanical environment with implant migration.

Authors:  A Perillo-Marcone; L Ryd; K Johnsson; M Taylor
Journal:  J Biomech       Date:  2004-08       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.