Literature DB >> 18514318

Combining nerve fiber layer parameters to optimize glaucoma diagnosis with optical coherence tomography.

Ake Tzu-Hui Lu1, Mingwu Wang, Rohit Varma, Joel S Schuman, David S Greenfield, Scott D Smith, David Huang.   

Abstract

PURPOSE: To identify the best combination of Stratus optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness parameters for the detection of glaucoma.
DESIGN: Observational cross-sectional study. PARTICIPANTS: Eighty-nine age-matched normal and perimetric glaucoma participants enrolled in the Advanced Imaging for Glaucoma Study.
METHODS: The Zeiss Stratus OCT system was used to obtain the circumpapillary RNFL thickness in both eyes of each participant. Right and left eye clock-hour data are analyzed together, assuming mirror-image symmetry. The RNFL diagnostic parameters were combined using either or-logic or and-logic approaches. MAIN OUTCOME MEASURES: Area under the receiver operating characteristic curve (AROC), sensitivity, and specificity are used to evaluate diagnostic performance.
RESULTS: Overall average RNFL thickness has the highest AROC value (0.89) of all single parameters evaluated, followed by the inferior and superior quadrants (0.88 and 0.86, respectively). The clock hours with the best AROC values are in the inferior and superior quadrants. The highest AROC (0.92) was achieved by the or-logic combination of overall, inferior, and superior quadrant RNFL thicknesses. The 3-parameter combination was significantly better than the overall average alone (P = 0.01). The addition of more quadrants or clock hours to the combination reduced diagnostic performance.
CONCLUSIONS: The best stand-alone diagnostic strategy for Stratus OCT RNFL data is to classify an eye as glaucomatous if the overall, inferior quadrant, or superior quadrant RNFL thickness average is below normal.

Entities:  

Mesh:

Year:  2008        PMID: 18514318      PMCID: PMC2756507          DOI: 10.1016/j.ophtha.2008.01.011

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  37 in total

1.  Sensitivity and specificity of new GDx parameters.

Authors:  Thomas P Colen; Nancy E M L Tang; Paul G H Mulder; Hans G Lemij
Journal:  J Glaucoma       Date:  2004-02       Impact factor: 2.503

2.  Fourier analysis of optical coherence tomography and scanning laser polarimetry retinal nerve fiber layer measurements in the diagnosis of glaucoma.

Authors:  Edward A Essock; Michael J Sinai; Christopher Bowd; Linda M Zangwill; Robert N Weinreb
Journal:  Arch Ophthalmol       Date:  2003-09

3.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

Authors:  Lelia A Paunescu; Joel S Schuman; Lori Lyn Price; Paul C Stark; Siobahn Beaton; Hiroshi Ishikawa; Gadi Wollstein; James G Fujimoto
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-06       Impact factor: 4.799

4.  Optic disc topography as measured by confocal scanning laser ophthalmoscopy and visual field loss in Japanese patients with primary open-angle or normal-tension glaucoma.

Authors:  Tomoko Nakatsue; Motohiro Shirakashi; Kiyoshi Yaoeda; Shigeo Funaki; Haruko Funaki; Atsushi Fukushima; Nobutaka Ofuchi; Haruki Abe
Journal:  J Glaucoma       Date:  2004-08       Impact factor: 2.503

5.  Comparison of data analysis tools for detection of glaucoma with the Heidelberg Retina Tomograph.

Authors:  Bryce A Ford; Paul H Artes; Terry A McCormick; Marcelo T Nicolela; Raymond P LeBlanc; Balwantray C Chauhan
Journal:  Ophthalmology       Date:  2003-06       Impact factor: 12.079

6.  Sensitivity and specificity of scanning laser polarimetry using the GDx.

Authors:  S Munkwitz; J Funk; K U Loeffler; U Harbarth; S Kremmer
Journal:  Br J Ophthalmol       Date:  2004-09       Impact factor: 4.638

7.  Optical coherence tomography (OCT) macular and peripapillary retinal nerve fiber layer measurements and automated visual fields.

Authors:  Gadi Wollstein; Joel S Schuman; Lori L Price; Ali Aydin; Siobahn A Beaton; Paul C Stark; James G Fujimoto; Hiroshi Ishikawa
Journal:  Am J Ophthalmol       Date:  2004-08       Impact factor: 5.258

8.  Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous human eyes.

Authors:  Viviane Guedes; Joel S Schuman; Ellen Hertzmark; Gadi Wollstein; Anthony Correnti; Ronald Mancini; David Lederer; Serineh Voskanian; Leonardo Velazquez; Helena M Pakter; Tamar Pedut-Kloizman; James G Fujimoto; Cynthia Mattox
Journal:  Ophthalmology       Date:  2003-01       Impact factor: 12.079

9.  Identifying early glaucoma with optical coherence tomography.

Authors:  Kouros Nouri-Mahdavi; Douglas Hoffman; Dana P Tannenbaum; Simon K Law; Joseph Caprioli
Journal:  Am J Ophthalmol       Date:  2004-02       Impact factor: 5.258

10.  Heidelberg retina tomograph measurements of the optic disc and parapapillary retina for detecting glaucoma analyzed by machine learning classifiers.

Authors:  Linda M Zangwill; Kwokleung Chan; Christopher Bowd; Jicuang Hao; Te-Won Lee; Robert N Weinreb; Terrence J Sejnowski; Michael H Goldbaum
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-09       Impact factor: 4.799

View more
  30 in total

1.  Combining spectral domain optical coherence tomography structural parameters for the diagnosis of glaucoma with early visual field loss.

Authors:  Jean-Claude Mwanza; Joshua L Warren; Donald L Budenz
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-12-30       Impact factor: 4.799

2.  Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis.

Authors:  Grace M Richter; Xinbo Zhang; Ou Tan; Brian A Francis; Vikas Chopra; David S Greenfield; Rohit Varma; Joel S Schuman; David Huang
Journal:  J Glaucoma       Date:  2016-08       Impact factor: 2.503

3.  Adaptive optics imaging of healthy and abnormal regions of retinal nerve fiber bundles of patients with glaucoma.

Authors:  Monica F Chen; Toco Y P Chui; Paula Alhadeff; Richard B Rosen; Robert Ritch; Alfredo Dubra; Donald C Hood
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-01-08       Impact factor: 4.799

4.  A new diagnostic model of primary open angle glaucoma based on FD-OCT parameters.

Authors:  Ya-Jie Zheng; Ying-Zi Pan; Xue-Ying Li; Yuan Fang; Mei Li; Rong-Hua Qiao; Yu Cai
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

5.  Diagnostic capability of spectral-domain optical coherence tomography for glaucoma.

Authors:  Huijuan Wu; Johannes F de Boer; Teresa C Chen
Journal:  Am J Ophthalmol       Date:  2012-01-20       Impact factor: 5.258

6.  Combining information from 3 anatomic regions in the diagnosis of glaucoma with time-domain optical coherence tomography.

Authors:  Mingwu Wang; Ake Tzu-Hui Lu; Rohit Varma; Joel S Schuman; David S Greenfield; David Huang
Journal:  J Glaucoma       Date:  2014-03       Impact factor: 2.503

7.  Structural changes of macular inner retinal layers in early normal-tension and high-tension glaucoma by spectral-domain optical coherence tomography.

Authors:  Florian S M Edlinger; Laura M Schrems-Hoesl; Christian Y Mardin; Robert Laemmer; Friedrich E Kruse; Wolfgang A Schrems
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-03-09       Impact factor: 3.117

8.  Comparison of multifocal visual evoked potential, standard automated perimetry and optical coherence tomography in assessing visual pathway in multiple sclerosis patients.

Authors:  Michal Laron; Han Cheng; Bin Zhang; Jade S Schiffman; Rosa A Tang; Laura J Frishman
Journal:  Mult Scler       Date:  2010-03-05       Impact factor: 6.312

9.  Estimated retinal ganglion cell counts in glaucomatous eyes with localized retinal nerve fiber layer defects.

Authors:  Andrew J Tatham; Robert N Weinreb; Linda M Zangwill; Jeffrey M Liebmann; Christopher A Girkin; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2013-06-07       Impact factor: 5.258

10.  First-visit diagnosis of preperimetric glaucoma.

Authors:  Avinoam Ophir
Journal:  Open Ophthalmol J       Date:  2010-05-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.