Literature DB >> 15289130

Optical coherence tomography (OCT) macular and peripapillary retinal nerve fiber layer measurements and automated visual fields.

Gadi Wollstein1, Joel S Schuman, Lori L Price, Ali Aydin, Siobahn A Beaton, Paul C Stark, James G Fujimoto, Hiroshi Ishikawa.   

Abstract

PURPOSE: To investigate the structure-function relationship between optical coherence tomography (OCT) macular retinal and peripapillary nerve fiber layer (NFL) thickness and automated visual field (VF) findings.
DESIGN: Cross-sectional observational study.
METHODS: Retrospective institutional study where 150 consecutive eyes (101 subjects) from a glaucoma service were included. All the participants had full ophthalmic evaluation, VF testing and prototype OCT scanning at the same visit. Orthogonal OCT macular analysis was obtained to maximize the sampling of the area of interest. Pearson age-adjusted correlation was determined between macular retinal thickness and peripapillary NFL thickness. Area under the receiver operator characteristics (AROC) curves for the association between macular retinal thickness and peripapillary NFL thickness and VF findings were calculated in a subgroup of eyes without VF defect and eyes with VF defect confined to one hemifield.
RESULTS: The correlation between macular retinal and peripapillary NFL measurements ranged between r =.27 to.54 for quadrants,.44 to.55 for hemiretina, and.52 for the overall mean. Areas under the receiver operator characteristics for macular thickness were higher in areas corresponding to the VF defect location than the noncorresponding locations. Areas under the receiver operator characteristics for peripapillary NFL thickness were higher than for the macular retinal thickness. Including both macular retinal thickness and peripapillary NFL thickness measurements in the logistic regression model yielded AROCs (range:.69 -.77) similar to those found for the peripapillary NFL alone.
CONCLUSION: Macular retinal thickness, as measured by OCT, was capable of detecting glaucomatous damage and corresponded with peripapillary NFL thickness; however, peripapillary NFL thickness had higher sensitivity and specificity for the detection of VF abnormalities.

Entities:  

Mesh:

Year:  2004        PMID: 15289130     DOI: 10.1016/j.ajo.2004.03.019

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  62 in total

1.  Use of microperimetry to compare macular light sensitivity in eyes with open-angle and angle-closure glaucoma.

Authors:  Ping Huang; Yan Shi; Xin Wang; Samuel Shao-Min Zhang; Chun Zhang
Journal:  Jpn J Ophthalmol       Date:  2011-12-10       Impact factor: 2.447

2.  Detection of macular and circumpapillary structural loss in normal hemifield areas of glaucomatous eyes with localized visual field defects using spectral-domain optical coherence tomography.

Authors:  Jung Hwa Na; Michael S Kook; Youngrok Lee; Sung Jin Yu; Jaewan Choi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-12-15       Impact factor: 3.117

3.  Structural and functional assessment of the macular region in patients with glaucoma.

Authors:  F N Kanadani; D C Hood; T M Grippo; B Wangsupadilok; N Harizman; V C Greenstein; J M Liebmann; R Ritch
Journal:  Br J Ophthalmol       Date:  2006-08-09       Impact factor: 4.638

4.  Detection and diagnosis of glaucoma: ocular imaging.

Authors:  Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-05-04       Impact factor: 4.799

5.  Influence of axial length on ganglion cell complex (GCC) thickness and on GCC thickness to retinal thickness ratios in young adults.

Authors:  Asuka Takeyama; Yoshiyuki Kita; Ritsuko Kita; Goji Tomita
Journal:  Jpn J Ophthalmol       Date:  2013-11-19       Impact factor: 2.447

6.  Improved retinal function after trabeculectomy in glaucoma patients.

Authors:  Elisabeth Wittström; Patrik Schatz; Monica Lövestam-Adrian; Vesna Ponjavic; Anders Bergström; Sten Andréasson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-10-29       Impact factor: 3.117

7.  Luminance-modulated adaptation in the global flash mfERG: a preliminary study of early retinal functional changes in high-risk glaucoma patients.

Authors:  Patrick H W Chu; Yiu-fai Ng; Chi-ho To; Kwok-fai So; Brian Brown; Henry H L Chan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-09-01       Impact factor: 3.117

8.  Macula Vessel Density and Foveal Avascular Zone Parameters in Exfoliation Glaucoma Compared to Primary Open-Angle Glaucoma.

Authors:  Shawn Philip; Ahmad Najafi; Apichat Tantraworasin; Toco Y P Chui; Richard B Rosen; Robert Ritch
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-03-01       Impact factor: 4.799

9.  Assessment of macular function of glaucomatous eyes by multifocal electroretinograms.

Authors:  Nobuhide Hori; Shinya Komori; Hiroki Yamada; Akira Sawada; Yasunori Nomura; Kiyofumi Mochizuki; Tetsuya Yamamoto
Journal:  Doc Ophthalmol       Date:  2012-09-04       Impact factor: 2.379

10.  Peripapillary fundus perimetry in eyes with glaucoma.

Authors:  E Convento; E Midena; M T Dorigo; V Maritan; F Cavarzeran; I A Fregona
Journal:  Br J Ophthalmol       Date:  2006-06-29       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.