PURPOSE: To determine whether differences in the optic disc topography and those in the relation between the optic disc topography and visual field indices exist between Japanese patients with primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG). METHODS: The study included consecutive Japanese patients with POAG (n = 60) or NTG (n = 60). Using the Heidelberg Retina Tomograph (HRT), we measured disc area, cup area, cup-to-disc area ratio, rim area, cup volume, rim volume, cup shape measure, and height variation contour. Each HRT parameter was measured in the total optic disc and in its four 90 degree quadrants (superior, temporal, inferior, and nasal). The mean deviation for the entire field and the sum of the total deviation values corresponding to each optic disc quadrant were calculated using the Humphrey full-threshold 30-2 program. RESULTS: No significant differences were found between the POAG and NTG groups for any HRT parameter either globally or regionally. There were no significant differences between the two groups in the correlation coefficients between any HRT parameter and the corresponding visual field indices either globally or regionally. CONCLUSION: No significant differences were apparent between Japanese patients with POAG and NTG both in the optic disc parameters as measured by HRT and in the degree of correlation between HRT parameter and the corresponding visual field indices.
PURPOSE: To determine whether differences in the optic disc topography and those in the relation between the optic disc topography and visual field indices exist between Japanese patients with primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG). METHODS: The study included consecutive Japanese patients with POAG (n = 60) or NTG (n = 60). Using the Heidelberg Retina Tomograph (HRT), we measured disc area, cup area, cup-to-disc area ratio, rim area, cup volume, rim volume, cup shape measure, and height variation contour. Each HRT parameter was measured in the total optic disc and in its four 90 degree quadrants (superior, temporal, inferior, and nasal). The mean deviation for the entire field and the sum of the total deviation values corresponding to each optic disc quadrant were calculated using the Humphrey full-threshold 30-2 program. RESULTS: No significant differences were found between the POAG and NTG groups for any HRT parameter either globally or regionally. There were no significant differences between the two groups in the correlation coefficients between any HRT parameter and the corresponding visual field indices either globally or regionally. CONCLUSION: No significant differences were apparent between Japanese patients with POAG and NTG both in the optic disc parameters as measured by HRT and in the degree of correlation between HRT parameter and the corresponding visual field indices.
Authors: Kyoung Tak Ma; Chan Yun Kim; Gong Je Seong; Seung Hyuck Lee; Jong Woon Park; Seung Joo Ha; Byung Joo Cho; Jeanette A Stewart; Michael S Kristoffersen; Lindsay A Nelson; William C Stewart Journal: Int Ophthalmol Date: 2011-09-08 Impact factor: 2.031
Authors: Oraorn Thonginnetra; Vivienne C Greenstein; David Chu; Jeffrey M Liebmann; Robert Ritch; Donald C Hood Journal: J Glaucoma Date: 2010-03 Impact factor: 2.503
Authors: Ake Tzu-Hui Lu; Mingwu Wang; Rohit Varma; Joel S Schuman; David S Greenfield; Scott D Smith; David Huang Journal: Ophthalmology Date: 2008-06-02 Impact factor: 12.079