Evaluation of exposure dose to patients undergoing catheter ablation procedures--a phantom study.

S Seguchi1, T Aoyama, S Koyama, C Kawaura, K Fujii.   

Abstract

The aim of this study was to evaluate entrance skin dose (ESD), organ dose and effective dose to patients undergoing catheter ablation for cardiac arrhythmias, based on the dosimetry in an anthropomorphic phantom. ESD values associated with mean fluoroscopy time and digital cine frames were in a range of 0.12-0.30 Gy in right anterior oblique (RAO) and 0.05-0.40 Gy in left anterior oblique (LAO) projection, the values which were less than a threshold dose of 2 Gy for the onset of skin injury. Organs that received high doses in ablation procedures were lung, followed by bone surface, esophagus, liver and red bone marrow. Doses for lung were 24.8-122.7 mGy, and effective doses were 7.9-34.8 mSv for mean fluoroscopy time of 23.4-92.3 min and digital cine frames of 263-511. Conversion coefficients of dose-area product (DAP) to ESD were 8.7 mGy/(Gy cm(2)) in RAO and 7.4 mGy/(Gy cm(2)) in LAO projection. The coefficients of DAP to the effective dose were 0.37 mSv/(Gy cm(2)) in RAO, and 0.41 mSv/(Gy cm(2)) in LAO projection. These coefficients enabled us to estimate patient exposure in real time by using monitored values of DAP.

Entities:  

Mesh:

Year:  2008        PMID: 18491105     DOI: 10.1007/s00330-008-1025-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  17 in total

1.  Skin dose and dose-area product values for interventional cardiology procedures.

Authors:  E Vano; L Gonzalez; J I Ten; J M Fernandez; E Guibelalde; C Macaya
Journal:  Br J Radiol       Date:  2001-01       Impact factor: 3.039

2.  Radiation doses to patients undergoing coronary angiography and percutaneous transluminal coronary angioplasty.

Authors:  M G Delichas; K Psarrakos; E Molyvda-Athanassopoulou; G Giannoglou; K Hatziioannou; E Papanastassiou
Journal:  Radiat Prot Dosimetry       Date:  2003       Impact factor: 0.972

3.  Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures.

Authors:  K Perisinakis; J Damilakis; N Theocharopoulos; E Manios; P Vardas; N Gourtsoyiannis
Journal:  Circulation       Date:  2001-07-03       Impact factor: 29.690

Review 4.  Basic anatomical and physiological data for use in radiological protection: the skeleton. A report of a Task Group of Committee 2 of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  1995

5.  Radiation exposure during catheter ablation of atrial fibrillation.

Authors:  Lars Lickfett; Mahadevappa Mahesh; Chandra Vasamreddy; David Bradley; Vinod Jayam; Zayd Eldadah; Timm Dickfeld; Deborah Kearney; Darshan Dalal; Berndt Lüderitz; Ronald Berger; Hugh Calkins
Journal:  Circulation       Date:  2004-10-25       Impact factor: 29.690

6.  Patient and staff radiation dosimetry during cardiac electrophysiology studies and catheter ablation procedures: a comprehensive analysis.

Authors:  Efstathios P Efstathopoulos; Demosthenes G Katritsis; Sofia Kottou; Nectarios Kalivas; Efthalia Tzanalaridou; Eleftherios Giazitzoglou; Socrates Korovesis; Keith Faulkner
Journal:  Europace       Date:  2006-05-11       Impact factor: 5.214

7.  Conceptus radiation dose and risk from cardiac catheter ablation procedures.

Authors:  J Damilakis; N Theocharopoulos; K Perisinakis; E Manios; P Dimitriou; P Vardas; N Gourtsoyiannis
Journal:  Circulation       Date:  2001-08-21       Impact factor: 29.690

8.  Electrophysiological breakthroughs from the left atrium to the pulmonary veins.

Authors:  M Haïssaguerre; D C Shah; P Jaïs; M Hocini; T Yamane; I Deisenhofer; M Chauvin; S Garrigue; J Clémenty
Journal:  Circulation       Date:  2000-11-14       Impact factor: 29.690

9.  Patient dose from barium procedures.

Authors:  R Ruiz-Cruces; F Ruiz; M Pérez-Martínez; J López; I Tort Ausina; A D de los Ríos
Journal:  Br J Radiol       Date:  2000-07       Impact factor: 3.039

10.  Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology.

Authors:  D Bor; T Sancak; T Olgar; Y Elcim; A Adanali; U Sanlidilek; S Akyar
Journal:  Br J Radiol       Date:  2004-04       Impact factor: 3.039

View more
  2 in total

1.  Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantoms.

Authors:  K Fujii; T Aoyama; C Yamauchi-Kawaura; S Koyama; M Yamauchi; S Ko; K Akahane; K Nishizawa
Journal:  Br J Radiol       Date:  2009-12       Impact factor: 3.039

2.  An organ and effective dose study of XVI and OBI cone-beam CT systems.

Authors:  Daniel E Hyer; Christopher F Serago; Siyong Kim; Jonathan G Li; David E Hintenlang
Journal:  J Appl Clin Med Phys       Date:  2010-04-17       Impact factor: 2.102

  2 in total