Literature DB >> 12593434

Radiation doses to patients undergoing coronary angiography and percutaneous transluminal coronary angioplasty.

M G Delichas1, K Psarrakos, E Molyvda-Athanassopoulou, G Giannoglou, K Hatziioannou, E Papanastassiou.   

Abstract

A detailed study of radiation doses received by 168 patients who underwent coronary angiography (CAG) and 102 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) in two Greek hospitals is presented. Radiation dose was measured in terms of dose-area product (DAP). The contribution of fluoroscopy and cineradiography to the total DAP was examined separately for each radiological projection used in both procedures. Effective dose and doses to various organs were estimated with the help of the ODS-60 software. Total DAP was found to correlate linearly to fluoroscopy time and cine film length. Mean DAP values were found to be 80.8 +/- 28.0 Gy cm2 for CAG and 86.2 +/- 65.6 Gy cm2 for PTCAs, whereas the estimated mean values of effective dose were 20.9 +/- 7.5 and 23.2 +/- 18.1 mSv respectively. DAP to effective dose conversion coefficients were estimated to be 0.26 mSv/Gy cm2 for CAG and 0.27 mSv/Gy cm2 for PTCAs.

Entities:  

Mesh:

Year:  2003        PMID: 12593434     DOI: 10.1093/oxfordjournals.rpd.a006126

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  7 in total

1.  The seamless integration of three-dimensional rotational angiography images into electroanatomical mapping systems to guide catheter ablation of atrial fibrillation.

Authors:  Satoshi Fujita; Eitaro Fujii; Yoshihiko Kagawa; Katsuhiro Inoue; Tsuyoshi Yamada; Masaaki Ito
Journal:  Heart Vessels       Date:  2018-05-07       Impact factor: 2.037

2.  Radiation-reducing planning of cardiac catheterisation.

Authors:  E Kuon; J B Dahm; D M Robinson; K Empen; M Günther; W Wucherer
Journal:  Z Kardiol       Date:  2005-10

3.  Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography.

Authors:  Anja Deetjen; Susanne Möllmann; Guido Conradi; Andreas Rolf; Axel Schmermund; Christian W Hamm; Thorsten Dill
Journal:  Heart       Date:  2007-03-29       Impact factor: 5.994

4.  Evaluation of exposure dose to patients undergoing catheter ablation procedures--a phantom study.

Authors:  S Seguchi; T Aoyama; S Koyama; C Kawaura; K Fujii
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

5.  Does Ad Hoc Coronary Intervention Reduce Radiation Exposure? - Analysis of 568 Patients.

Authors:  Márcio A M Truffa; Gustavo M P Alves; Fernando Bernardi; Antonio Esteves Filho; Expedito Ribeiro; Micheli Z Galon; André Spadaro; Luiz J Kajita; Raul Arrieta; Pedro A Lemos
Journal:  Arq Bras Cardiol       Date:  2015-09-08       Impact factor: 2.000

6.  Radiation doses and estimated risk from angiographic projections during coronary angiography performed using novel flat detector.

Authors:  Anna Varghese; Roshan S Livingstone; Lijo Varghese; Parveen Kumar; Sirish Chandra Srinath; Oommen K George; Paul V George
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

7.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.