Literature DB >> 11227777

Skin dose and dose-area product values for interventional cardiology procedures.

E Vano1, L Gonzalez, J I Ten, J M Fernandez, E Guibelalde, C Macaya.   

Abstract

Coronary angiography and percutaneous transluminal coronary angioplasty procedures performed in four different facilities were monitored in the present study by measuring maximum skin dose, dose-area product and other operational parameters. Radiographic slow film, thermoluminescent dosemeters and transmission ion chambers were used to measure dose related quantities. Values of 107-711 mGy for maximum skin dose and 27.3-370.6 Gy cm2 for dose-area product were found, together with cumulative skin dose estimates of 110-3706 mGy. A discussion of the relationship of measured dose-area product and skin dose values is made using a field concentration factor defined as a way to interpret the findings. No general correlation was observed between dose-area product and maximum skin dose. Cumulative skin dose estimates throughout a procedure should be discarded as a realistic method for assessing deterministic risk in cardiology procedures. Slow film in addition to thermoluminescent dosemeters for measurement of maximum skin dose is a good alternative, especially for complex interventional procedures. For repeated procedures, combining film and dose-area product monitoring favours optimization of radiation protection for the patient.

Entities:  

Mesh:

Year:  2001        PMID: 11227777     DOI: 10.1259/bjr.74.877.740048

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  21 in total

1.  Main clinical, therapeutic and technical factors related to patient's maximum skin dose in interventional cardiology procedures.

Authors:  N Journy; S Sinno-Tellier; C Maccia; A Le Tertre; P Pirard; P Pagès; D Eilstein; J Donadieu; O Bar
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

Review 2.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

3.  The seamless integration of three-dimensional rotational angiography images into electroanatomical mapping systems to guide catheter ablation of atrial fibrillation.

Authors:  Satoshi Fujita; Eitaro Fujii; Yoshihiko Kagawa; Katsuhiro Inoue; Tsuyoshi Yamada; Masaaki Ito
Journal:  Heart Vessels       Date:  2018-05-07       Impact factor: 2.037

4.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

5.  Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplasty.

Authors:  V Sadick; W Reed; L Collins; N Sadick; R Heard; J Robinson
Journal:  Br J Radiol       Date:  2009-12-17       Impact factor: 3.039

6.  Real-time eye lens dose monitoring during cerebral angiography procedures.

Authors:  M J Safari; J H D Wong; K A A Kadir; N K Thorpe; D L Cutajar; M Petasecca; M L F Lerch; A B Rosenfeld; K H Ng
Journal:  Eur Radiol       Date:  2015-05-23       Impact factor: 5.315

7.  Reference levels and patient doses in interventional cardiology procedures in Greece.

Authors:  George Simantirakis; Christina Koukorava; Maria Kalathaki; Christos Pafilis; Ioannis Kaisas; Sotirios Economides; Costas J Hourdakis; Vassiliki Kamenopoulou; Evaggelos Georgiou
Journal:  Eur Radiol       Date:  2013-04-06       Impact factor: 5.315

8.  Radiation dose to the brain and subsequent risk of developing brain tumors in pediatric patients undergoing interventional neuroradiology procedures.

Authors:  I Thierry-Chef; S L Simon; C E Land; D L Miller
Journal:  Radiat Res       Date:  2008-11       Impact factor: 2.841

9.  Evaluation of exposure dose to patients undergoing catheter ablation procedures--a phantom study.

Authors:  S Seguchi; T Aoyama; S Koyama; C Kawaura; K Fujii
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

10.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.