Literature DB >> 16690631

Patient and staff radiation dosimetry during cardiac electrophysiology studies and catheter ablation procedures: a comprehensive analysis.

Efstathios P Efstathopoulos1, Demosthenes G Katritsis, Sofia Kottou, Nectarios Kalivas, Efthalia Tzanalaridou, Eleftherios Giazitzoglou, Socrates Korovesis, Keith Faulkner.   

Abstract

AIMS: To perform a comprehensive analysis of all aspects of patient and in-room personnel radiation dosimetry in interventional electrophysiology. METHODS AND
RESULTS: Measurements were performed during 19 diagnostic electrophysiology studies and 24 catheter ablations. Kerma-area product and exposure time values were 48.7 (6.4-230) Gy cm2 and 25.5 (4.4-79.2) min for ablation, and 12.5 (4.5-117.2) Gy cm2 and 4.5 (1.2-31) min for diagnostic studies, respectively. Patient effective doses were 15.2 (2.1-59.6) mSv for ablation and 3.2 (1.3-23.9) mSv for diagnostic procedures. Radiation risk to the patient was estimated to be up to eight cases of fatal cancer in 10,000 procedures. The risk of development of fatal cancer was less than 3x10(-6) per procedure to the primary operator. The risk for the nurse and technician was much lower. The dose per procedure for the primary operator was 7.1 microGy at the eyes, 0.79 microGy at the chest under the lead apron, 13.68 microGy at the chest over the apron, 3.82 microGy at the thyroid, 17.76 microGy at the left hand, and 12.11 microGy at the left knee.
CONCLUSION: As far as radiation exposure is concerned, electrophysiology studies followed by radiofrequency ablation are safe procedures for both patient and personnel when performed in catheterization laboratories with modern equipment, experienced operators, and standard safety precautions.

Entities:  

Mesh:

Year:  2006        PMID: 16690631     DOI: 10.1093/europace/eul041

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  17 in total

Review 1.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Physicians' exposure to radiation during electrophysiology procedures.

Authors:  Laurent Faroux; Charline Daval; François Lesaffre; Thierry Blanpain; Jean-Pierre Chabert; Angeline Martin; Mathias Guinot; Nicolas Luconi; Madeline Espinosa; Pierre Nazeyrollas; Christophe Tourneux; Damien Metz
Journal:  J Interv Card Electrophysiol       Date:  2019-06-08       Impact factor: 1.900

3.  Minimal use of fluoroscopy to reduce fetal radiation exposure during radiofrequency catheter ablation of maternal supraventricular tachycardia.

Authors:  Ajay Sundara Raman; Saumya Sharma; Ramesh Hariharan
Journal:  Tex Heart Inst J       Date:  2015-04-01

4.  Contrast-Enhanced C-arm Computed Tomography Imaging of Myocardial Infarction in the Interventional Suite.

Authors:  Erin E Girard; Amin Al-Ahmad; Jarrett Rosenberg; Richard Luong; Teri Moore; Günter Lauritsch; Frandics Chan; David P Lee; Rebecca Fahrig
Journal:  Invest Radiol       Date:  2015-06       Impact factor: 6.016

5.  Reference levels and patient doses in interventional cardiology procedures in Greece.

Authors:  George Simantirakis; Christina Koukorava; Maria Kalathaki; Christos Pafilis; Ioannis Kaisas; Sotirios Economides; Costas J Hourdakis; Vassiliki Kamenopoulou; Evaggelos Georgiou
Journal:  Eur Radiol       Date:  2013-04-06       Impact factor: 5.315

6.  Contrast-enhanced C-arm CT evaluation of radiofrequency ablation lesions in the left ventricle.

Authors:  Erin E Girard; Amin Al-Ahmad; Jarrett Rosenberg; Richard Luong; Teri Moore; Günter Lauritsch; Jan Boese; Rebecca Fahrig
Journal:  JACC Cardiovasc Imaging       Date:  2011-03

7.  Impact of respiration gating on image integration guided atrial fibrillation ablation.

Authors:  Emin Evren Özcan; Gabor Szeplaki; Tamas Tahin; Istvan Osztheimer; Szabolcs Szilagyi; Astrid Apor; Pal Maurovich Horvath; Hajnalka Vago; Béla Merkely; Laszlo Geller
Journal:  Clin Res Cardiol       Date:  2014-05-07       Impact factor: 5.460

8.  Impact of a comprehensive safety program on radiation exposure during catheter ablation of atrial fibrillation: a prospective study.

Authors:  Dhanunjaya Lakkireddy; George Nadzam; Atul Verma; Subramanya Prasad; Kay Ryschon; Luigi Di Biase; Mohammed Khan; David Burkhardt; Robert Schweikert; Andrea Natale
Journal:  J Interv Card Electrophysiol       Date:  2008-11-06       Impact factor: 1.900

9.  Initial clinical experience of remote magnetic navigation system for catheter mapping and ablation of supraventricular tachycardias.

Authors:  Dongjie Xu; Bin Yang; Qijun Shan; Jiangang Zou; Minglong Chen; Chun Chen; Xiaofeng Hou; Fengxiang Zhang; Wen-Qi Li; Kejiang Cao; Hung-Fat Tse
Journal:  J Interv Card Electrophysiol       Date:  2009-03-05       Impact factor: 1.900

10.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.