Fluctuation in measurements of pulmonary nodule under tidal volume ventilation on four-dimensional computed tomography: preliminary results.

Ukihide Tateishi1, Shinsuke Tsukagoshi, Hiroyasu Inokawa, Miwa Okumura, Noriyuki Moriyama.   

Abstract

The present study aimed to assess the feasibility of four-dimensional (4D) chest computed tomography (CT) under tidal volume ventilation and the impact of respiratory motion on quantitative analysis of CT measurements. Forty-four pulmonary nodules in patients with metastatic disease were evaluated. CT examinations were performed using a 256 multidetector-row CT (MDCT) unit. Volume data were obtained from the lower lung fields (128 mm) above the diaphragm during dynamic CT acquisition. The CT parameters used were 120 kV, 100 or 150 mA, 0.5 s(-1), and 0.5 mm collimation. Image data were reconstructed every 0.1 s during one respiratory cycle by a 180 degrees reconstruction algorithm for four independent fractions of the respiratory cycle. Pulmonary nodules were measured along their longest and shortest axes using electronic calipers. Automated volumetry was assessed using commercially available software. The diameters of long and short axes in each frame were 9.0-9.6 mm and 7.1-7.5 mm, respectively. There was fluctuation of the long axis diameters in the third fraction. The mean volume in each fraction ranged from 365 to 394 mm(3). Statistically significant fluctuation was also found in the third fraction. 4D-CT under tidal volume ventilation is feasible to determine diameter or volume of the pulmonary nodule.

Entities:  

Mesh:

Year:  2008        PMID: 18458912     DOI: 10.1007/s00330-008-1002-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  18 in total

1.  Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility.

Authors:  Dag Wormanns; Gerhard Kohl; Ernst Klotz; Anke Marheine; Florian Beyer; Walter Heindel; Stefan Diederich
Journal:  Eur Radiol       Date:  2003-11-13       Impact factor: 5.315

2.  Real-time volumetric imaging of human heart without electrocardiographic gating by 256-detector row computed tomography: initial experience.

Authors:  Chisato Kondo; Shinichiro Mori; Masahiro Endo; Kiyoko Kusakabe; Naoki Suzuki; Asaki Hattori; Masahiro Kusakabe
Journal:  J Comput Assist Tomogr       Date:  2005 Sep-Oct       Impact factor: 1.826

3.  Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot.

Authors:  T G Flohr; K Stierstorfer; S Ulzheimer; H Bruder; A N Primak; C H McCollough
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

4.  Cardiac imaging using 256-detector row four-dimensional CT: preliminary clinical report.

Authors:  Teruhito Kido; Akira Kurata; Hiroshi Higashino; Yoshifumi Sugawara; Hideki Okayama; Jitsuo Higaki; Hirofumi Anno; Kazuhiro Katada; Shinichiro Mori; Shuji Tanada; Masahiro Endo; Teruhito Mochizuki
Journal:  Radiat Med       Date:  2007-01-25

5.  Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study.

Authors:  Harald Brodoefel; Ulrich Kramer; Anja Reimann; Christof Burgstahler; Stephen Schroeder; Andreas Kopp; Martin Heuschmid
Journal:  AJR Am J Roentgenol       Date:  2007-11       Impact factor: 3.959

6.  Evaluation of dose exposure in 64-slice CT colonography.

Authors:  O Luz; M Buchgeister; M Klabunde; T Trabold; A F Kopp; C D Claussen; M Heuschmid
Journal:  Eur Radiol       Date:  2007-02-07       Impact factor: 5.315

7.  A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion.

Authors:  Anthony E Lujan; James M Balter; Randall K Ten Haken
Journal:  Med Phys       Date:  2003-10       Impact factor: 4.071

8.  CT evaluation of patient deep inspiration self-breath-holding: how precisely can patients reproduce the tumor position in the absence of respiratory monitoring devices?

Authors:  Hiroshi Onishi; Kengo Kuriyama; Takafumi Komiyama; Shiho Tanaka; Junko Ueki; Naoki Sano; Tsutomu Araki; Satoshi Ikenaga; Yoshihito Tateda; Yoshihito Aikawa
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

9.  Reduction of normal lung irradiation in locally advanced non-small-cell lung cancer patients, using ventilation images for functional avoidance.

Authors:  Brian P Yaremko; Thomas M Guerrero; Josue Noyola-Martinez; Rudy Guerra; David G Lege; Linda T Nguyen; Peter A Balter; James D Cox; Ritsuko Komaki
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-29       Impact factor: 7.038

10.  Assessment of intrafraction mediastinal and hilar lymph node movement and comparison to lung tumor motion using four-dimensional CT.

Authors:  Eric D Donnelly; Parag J Parikh; Wei Lu; Tianyu Zhao; Kristen Lechleiter; Michelle Nystrom; James P Hubenschmidt; Daniel A Low; Jeffrey D Bradley
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-01       Impact factor: 7.038

View more
  1 in total

1.  Pulmonary Nodules: growth rate assessment in patients by using serial CT and three-dimensional volumetry.

Authors:  Jane P Ko; Erika J Berman; Manmeen Kaur; James S Babb; Elan Bomsztyk; Alissa K Greenberg; David P Naidich; Henry Rusinek
Journal:  Radiology       Date:  2011-12-09       Impact factor: 11.105