Literature DB >> 17954641

Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study.

Harald Brodoefel1, Ulrich Kramer, Anja Reimann, Christof Burgstahler, Stephen Schroeder, Andreas Kopp, Martin Heuschmid.   

Abstract

OBJECTIVE: Functional analysis using MDCT has been limited by insufficient temporal resolution. The aim of this study was to assess the performance of a dual-source CT system with improved temporal resolution in the determination of both volume- or time-dependent functional parameters and regional wall motion in comparison with cine MRI. SUBJECTS AND METHODS: Twenty patients (15 of whom had previous myocardial infarction) were prospectively examined using dual-source CT. MRI was used as the standard of reference. Using the Simpson's method, ventricular volumes were determined for the whole of the cardiac cycle and results compared using Parson's correlation and Bland-Altman analysis. Regional wall motion was assessed on cine images and compared using weighted kappa statistics.
RESULTS: Dual-source CT revealed a strong correlation with cine MRI regarding the quantification of end-diastolic volume (r = 0.98), end-systolic volume (r = 0.99), stroke volume (r = 0.96), and ejection fraction (r = 0.95). Good correlation was obtained for peak ejection rate (r = 0.79) and peak filling rate (r = 0.84), whereas agreement proved only moderate for time-to-peak ejection rate (r = 0.68) or time-to-peak filling rate from end-systole (r = 0.64). The mean difference for ejection fraction was negligible (bias, 0.72%). Good agreement between both techniques was likewise found for regional wall motion (kappa = 0.88).
CONCLUSION: With the improvement of temporal resolution between 42 and 83 milliseconds, dual-source CT not only enables accurate assessment of global functional parameters, but it also allows for quantification of time-dependent variables and reliable evaluation of regional wall motion.

Entities:  

Mesh:

Year:  2007        PMID: 17954641     DOI: 10.2214/AJR.07.2228

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  20 in total

1.  Accuracy of automated attenuation-based 3-dimensional segmentation: in the analysis of left ventricular function compared with magnetic resonance imaging.

Authors:  Harald Brodoefel; Ilias Tsiflikas; Ulrich Kramer; Nina Lang; Anja Reimann; Christoph Burgstahler; Claus D Claussen; Martin Heuschmid
Journal:  Tex Heart Inst J       Date:  2012

Review 2.  Novel techniques for assessment of left ventricular systolic function.

Authors:  Sonal Chandra; Hicham Skali; Ron Blankstein
Journal:  Heart Fail Rev       Date:  2011-07       Impact factor: 4.214

3.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

4.  Evaluation of global left ventricular function assessment by dual-source computed tomography compared with MRI.

Authors:  Pieter A van der Vleuten; Gonda J de Jonge; Daniël D Lubbers; René A Tio; Tineke P Willems; Matthijs Oudkerk; Felix Zijlstra
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

Review 5.  History of cardiac computed tomography: single to 320-detector row multislice computed tomography.

Authors:  Gregory S Hurlock; Hiroshi Higashino; Teruhito Mochizuki
Journal:  Int J Cardiovasc Imaging       Date:  2009-01-15       Impact factor: 2.357

6.  Assessing the left atrial phasic volume and function with dual-source CT: comparison with 3T MRI.

Authors:  Zhaoying Wen; Zhaoqi Zhang; Wei Yu; Zhanming Fan; Jing Du; Biao Lv
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

Review 7.  CT for assessing ventricular remodeling: is it ready for prime time?

Authors:  Gardar Sigurdsson
Journal:  Curr Heart Fail Rep       Date:  2008-03

8.  Fluctuation in measurements of pulmonary nodule under tidal volume ventilation on four-dimensional computed tomography: preliminary results.

Authors:  Ukihide Tateishi; Shinsuke Tsukagoshi; Hiroyasu Inokawa; Miwa Okumura; Noriyuki Moriyama
Journal:  Eur Radiol       Date:  2008-05-06       Impact factor: 5.315

9.  Global left-ventricular function assessment using dual-source multidetector CT: effect of improved temporal resolution on ventricular volume measurement.

Authors:  Michael Puesken; Roman Fischbach; Mirja Wenker; Harald Seifarth; David Maintz; Walter Heindel; Kai Uwe Juergens
Journal:  Eur Radiol       Date:  2008-05-01       Impact factor: 5.315

10.  Novel phase-based noise reduction strategy for quantification of left ventricular function and mass assessment by cardiac CT: comparison with cardiac magnetic resonance.

Authors:  Bryan Wai; Wai-Ee Thai; Heather Brown; Quynh A Truong
Journal:  Eur J Radiol       Date:  2013-03-20       Impact factor: 3.528

View more