Literature DB >> 16163045

Real-time volumetric imaging of human heart without electrocardiographic gating by 256-detector row computed tomography: initial experience.

Chisato Kondo1, Shinichiro Mori, Masahiro Endo, Kiyoko Kusakabe, Naoki Suzuki, Asaki Hattori, Masahiro Kusakabe.   

Abstract

OBJECTIVE: The feasibility of human cardiac imaging using a prototype 256-detector row cone-beam computed tomography (256CBCT) scanner without electrocardiographic gating was examined.
METHODS: Two healthy male volunteers were examined by contrast-enhanced 256CBCT. The number of detectors was 912 x 256, each measuring approximately 0.5 mm x 0.5 mm at the center of rotation. The craniocaudal coverage was approximately 100 mm after reconstruction by the Feldkamp-Davis-Kress algorithm. The effective time resolution was 500 milliseconds using a half-scan algorithm.
RESULTS: Serial enhancement of the left ventricular myocardium was detected. The right and left coronary arteries at proximal and distal segments were depicted without significant blurring. Although the left ventricular wall motion on cine images was not smooth over time, it was possible to measure ventricular volume and ejection fraction.
CONCLUSIONS: Using the 256CBCT, it was possible to visualize the coronary arteries, myocardial perfusion, and ventricular contraction simultaneously during a single acquisition.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16163045     DOI: 10.1097/01.rct.0000173844.89988.37

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  11 in total

1.  Reperfusion injury components and manifestations determined by cardiovascular MR and MDCT imaging.

Authors:  Maythem Saeed; Steve Hetts; Mark Wilson
Journal:  World J Radiol       Date:  2010-01-28

2.  Properties of the prototype 256-row (cone beam) CT scanner.

Authors:  Shinichiro Mori; Masahiro Endo; Takayuki Obata; Takanori Tsunoo; Kandatsu Susumu; Shuji Tanada
Journal:  Eur Radiol       Date:  2006-03-28       Impact factor: 5.315

3.  Cardiac imaging using 256-detector row four-dimensional CT: preliminary clinical report.

Authors:  Teruhito Kido; Akira Kurata; Hiroshi Higashino; Yoshifumi Sugawara; Hideki Okayama; Jitsuo Higaki; Hirofumi Anno; Kazuhiro Katada; Shinichiro Mori; Shuji Tanada; Masahiro Endo; Teruhito Mochizuki
Journal:  Radiat Med       Date:  2007-01-25

4.  Quantitative assessment of regional left ventricular wall thickness and thickening using 16 multidetector-row computed tomography: comparison with cine magnetic resonance imaging.

Authors:  Rene E Kanza; Hiroshi Higashino; Teruhito Kido; Akira Kurata; Makoto Saito; Yoshifumi Sugawara; Teruhito Mochizuki
Journal:  Radiat Med       Date:  2007-04-27

Review 5.  CT for assessing ventricular remodeling: is it ready for prime time?

Authors:  Gardar Sigurdsson
Journal:  Curr Heart Fail Rep       Date:  2008-03

6.  Fluctuation in measurements of pulmonary nodule under tidal volume ventilation on four-dimensional computed tomography: preliminary results.

Authors:  Ukihide Tateishi; Shinsuke Tsukagoshi; Hiroyasu Inokawa; Miwa Okumura; Noriyuki Moriyama
Journal:  Eur Radiol       Date:  2008-05-06       Impact factor: 5.315

7.  Development and performance evaluation of the second model 256-detector row CT.

Authors:  Masahiro Endo; Shinichiro Mori; Susumu Kandatsu; Shuji Tanada; Chisato Kondo
Journal:  Radiol Phys Technol       Date:  2007-11-01

8.  Influence of heart rate in the selection of the optimal reconstruction window in routine clinical multislice coronary angiography.

Authors:  G Runza; L La Grutta; V Alaimo; L Damiani; A La Fata; F Alberghina; M Galia; G Lo Re; G Luccichenti; T Bartolotta; F Cademartiri; M Midiri; M De Maria; R Lagalla
Journal:  Radiol Med       Date:  2008-07-01       Impact factor: 3.469

9.  [Coronary heart-CT].

Authors:  N Faucheron; P Reimer
Journal:  Radiologe       Date:  2008-07       Impact factor: 0.635

Review 10.  Developments in coronary CT angiography.

Authors:  Stephan Achenbach
Journal:  Curr Cardiol Rep       Date:  2008-02       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.