Literature DB >> 18405820

Comparison of hand-traced and computerized cephalograms: landmark identification, measurement, and superimposition accuracy.

Dustin Roden-Johnson1, Jeryl English, Ronald Gallerano.   

Abstract

INTRODUCTION: The purposes of this study were (1) to investigate the variations of landmark identification between film and digital cephalometric tracings, (2) to compare the ability of Quick Ceph 2000 (Quick Ceph Systems, Inc, San Diego, Calif) to measure the linear and angular measurements with the hand-traced method, and (3) to compare Quick Ceph 2000 superimpositions to the hand-traced method of superimpositions that are currently accepted by the American Board of Orthodontics (ABO). MATERIALS: We used 30 sets of serial cephalometric radiographs of growing patients from 1 orthodontic office. Fiduciary x- and y-axes were drawn in pencil on the T1 radiographs in the regions of the cranial base, the maxilla, and the mandible. The fiduciary lines were transferred to the digital and film serial cephalograms by regionally superimposing the tracings as described in the ABO Phase III examination handbook. A Mann-Whitney test was done to compare the median and Delta of the T1 and T2 values for each measurement acquired by hand and by Quick Ceph. RESULTS AND
CONCLUSIONS: There was no difference in the identification of cephalometric landmarks made manually vs digitally with Quick Ceph 2000. There was no difference in acquiring consistent cephalometric values for the measurements required by the ABO for the Phase III clinical examination manually vs digitally by using Quick Ceph 2000. There was no difference in the regional superimpositions of the mandible, the maxilla, and the cranial base, manually vs digitally with Quick Ceph 2000.

Entities:  

Mesh:

Year:  2008        PMID: 18405820     DOI: 10.1016/j.ajodo.2006.03.041

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  14 in total

1.  Influence of a programme of professional calibration in the variability of landmark identification using cone beam computed tomography-synthesized and conventional radiographic cephalograms.

Authors:  E L Delamare; G S Liedke; M B Vizzotto; H L D da Silveira; J L D Ribeiro; H E D Silveira
Journal:  Dentomaxillofac Radiol       Date:  2010-10       Impact factor: 2.419

2.  Novel information theory based method for superimposition of lateral head radiographs and cone beam computed tomography images.

Authors:  W Jacquet; E Nyssen; P Bottenberg; P de Groen; B Vande Vannet
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

3.  The applicability of a non-anatomical soft and hard tissue centroid line (S&H centroid) in cephalometrics.

Authors:  Ibrahim S Al-Shahrani; Khalid M Al-Balkhi; Abdulaziz Al-Madi
Journal:  Saudi Dent J       Date:  2010-02-06

4.  Comparative evaluation of cephalometric measurements of monitor-displayed images by Nemoceph software and its hard copy by manual tracing.

Authors:  Tripti Tikku; Rohit Khanna; R P Maurya; Kamna Srivastava; Rastra Bhushan
Journal:  J Oral Biol Craniofac Res       Date:  2014-01-08

5.  Assessing lower incisor inclination change: a comparison of four cephalometric methods.

Authors:  Amritraj Jabbal; Martyn Cobourne; Nora Donaldson; Dirk Bister
Journal:  Eur J Orthod       Date:  2015-04-17       Impact factor: 3.075

6.  Comparative Evaluation of Conventional and OnyxCeph™ Dental Software Measurements on Cephalometric Radiography.

Authors:  Elif İzgi; Filiz Namdar Pekiner
Journal:  Turk J Orthod       Date:  2019-06-01

7.  Improved lateral cephalometric superimposition using an automated image fitting technique.

Authors:  Brent E Larson; Matthew M Sievers; Ching-Chang Ko
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

8.  Soft tissue images from cephalograms compared with those from a 3D surface acquisition system.

Authors:  Angela K Incrapera; Chung How Kau; Jeryl D English; Kathleen McGrory; David M Sarver
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

9.  Effects of Palatal Expansion with Torque Activation using a Transpalatal Arch: A Preliminary Single-Blind Randomized Clinical Trial.

Authors:  Fataneh Ghorbanyjavadpour; Vahid Rakhshan
Journal:  Int J Dent       Date:  2021-06-01

10.  A Superimposition-Based Cephalometric Method to Quantitate Craniofacial Changes.

Authors:  Nameer Al-Taai; Eva Levring Jäghagen; Maurits Persson; Maria Ransjö; Anna Westerlund
Journal:  Int J Environ Res Public Health       Date:  2021-05-14       Impact factor: 3.390

View more