Literature DB >> 25737917

Comparative evaluation of cephalometric measurements of monitor-displayed images by Nemoceph software and its hard copy by manual tracing.

Tripti Tikku1, Rohit Khanna2, R P Maurya3, Kamna Srivastava4, Rastra Bhushan5.   

Abstract

OBJECTIVE: The aim of this study was to evaluate and compare the cephalometric measurements obtained from computerized tracing of direct digital radiographs and hand tracing of their digital radiographic printouts.
MATERIAL AND METHODS: The soft- and hard-copies of pre-treatment lateral cephalograms of 40 subjects (both males and females) within the age group of 10-30 years, irrespective of the type of malocclusion were taken. Total 26 measurements (13 linear and 13 angular) were obtained using both the manual and the digital technique.
RESULTS: Amongst the linear measurements, Anterior facial height (AFH), Posterior facial height (PFH), Upper lip length (ULL), Lower lip length (LLL), Anterior cranial base length (ACBL), Posterior cranial base length (PCBL), Maxillary length (MxL), Mandibular length (MdL), Lower incisor to NB line (L1 to NB) and Lower lip protrusion (LLP) showed statistically significant difference between the two techniques but were clinically acceptable (difference between the digital and manual technique were less than 2 units (1 unit = 1 mm for linear measurements and 1° for angular measurements). While amongst the angular measurements, only occlusal plane angle showed statistically significant difference between the two techniques that was not clinically acceptable.
CONCLUSION: Digital measurements obtained from monitor-displayed images (soft copy) were found to be reproducible and comparable to the manual method done on its hard copy, for all the measurements except occlusal plane angle (SN-occlusal plane).

Keywords:  Cephalometric measurements; Cephalometric software; Digital imaging

Year:  2014        PMID: 25737917      PMCID: PMC4252389          DOI: 10.1016/j.jobcr.2013.11.002

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  19 in total

1.  Landmark identification on direct digital versus film-based cephalometric radiographs: a human skull study.

Authors:  Ralf Kurt Willy Schulze; Matthias Burkhardt Gloede; Gerhard Michael Doll
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-12       Impact factor: 2.650

2.  A comparison of hand-tracing and cephalometric analysis computer programs with and without advanced features--accuracy and time demands.

Authors:  Georgios Tsorovas; Agneta Linder-Aronson Karsten
Journal:  Eur J Orthod       Date:  2010-06-16       Impact factor: 3.075

3.  Evaluation of speed, repeatability, and reproducibility of digital radiography with manual versus computer-assisted cephalometric analyses.

Authors:  Tancan Uysal; Asli Baysal; Ahmet Yagci
Journal:  Eur J Orthod       Date:  2009-05-14       Impact factor: 3.075

4.  Comparison of hand-traced and computerized cephalograms: landmark identification, measurement, and superimposition accuracy.

Authors:  Dustin Roden-Johnson; Jeryl English; Ronald Gallerano
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-04       Impact factor: 2.650

Review 5.  Digital imaging of cephalometric radiography, Part 1: Advantages and limitations of digital imaging.

Authors:  D B Forsyth; W C Shaw; S Richmond
Journal:  Angle Orthod       Date:  1996       Impact factor: 2.079

6.  The reliability of head film measurements. 2. Conventional angular and linear measures.

Authors:  S Baumrind; R C Frantz
Journal:  Am J Orthod       Date:  1971-11

7.  Computer-aided head film analysis: the University of California San Francisco method.

Authors:  S Baumrind; D M Miller
Journal:  Am J Orthod       Date:  1980-07

8.  Comparison of cephalometric measurements with digital versus conventional cephalometric analysis.

Authors:  Erkan Celik; Omur Polat-Ozsoy; T Ufuk Toygar Memikoglu
Journal:  Eur J Orthod       Date:  2009-02-23       Impact factor: 3.075

9.  Differences in cephalometric measurements: a comparison of digital versus hand-tracing methods.

Authors:  Omur Polat-Ozsoy; Aylin Gokcelik; T Ufuk Toygar Memikoglu
Journal:  Eur J Orthod       Date:  2009-04-06       Impact factor: 3.075

10.  Accuracy of digital and analogue cephalometric measurements assessed with the sandwich technique.

Authors:  Margherita Santoro; Karim Jarjoura; Thomas J Cangialosi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-03       Impact factor: 2.650

View more
  4 in total

1.  Comparative Evaluation of CephNinja for Android and NemoCeph for Computer for Cephalometric Analysis: A Study to Evaluate the Diagnostic Performance of CephNinja for Cephalometric Analysis.

Authors:  Mukesh Kumar; Sommya Kumari; Ambuj Chandna; Anju Singh; Harsh Kumar
Journal:  J Int Soc Prev Community Dent       Date:  2020-06-15

Review 2.  Role of Orthodontics in Forensic Odontology- A Social Responsibility.

Authors:  Giridhar Reddy; Vinay P Reddy; Meenakshi Sharma; Monika Aggarwal
Journal:  J Clin Diagn Res       Date:  2016-04-01

3.  Comparative Evaluation of Conventional and OnyxCeph™ Dental Software Measurements on Cephalometric Radiography.

Authors:  Elif İzgi; Filiz Namdar Pekiner
Journal:  Turk J Orthod       Date:  2019-06-01

4.  Ceph-X: development and evaluation of 2D cephalometric system.

Authors:  Mogeeb Ahmed Ahmed Mosleh; Mohd Sapiyan Baba; Sorayya Malek; Rasheed A Almaktari
Journal:  BMC Bioinformatics       Date:  2016-12-22       Impact factor: 3.169

  4 in total