Literature DB >> 20841459

Influence of a programme of professional calibration in the variability of landmark identification using cone beam computed tomography-synthesized and conventional radiographic cephalograms.

E L Delamare1, G S Liedke, M B Vizzotto, H L D da Silveira, J L D Ribeiro, H E D Silveira.   

Abstract

OBJECTIVES: The validity of any measurement obtained through a cephalogram largely depends on the reproducibility of the cephalometric landmarks. The purpose of this study is to evaluate the influence of a programme of professional calibration (PPC) on the variability of landmark identification comparing conventional radiographs and cone beam CT (CBCT)-synthesized cephalograms.
METHODS: 5 graduate students in oral radiology identified 20 cephalometric landmarks from cephalograms generated from conventional radiographs (RADs), Ray-Sum CBCT-synthesized cephalograms (CBTs) and half-skull CBT (HSTs) from 10 patients. After a period of reinforcement on instruction and calibration with inter- and intraexaminer assessment of reproducibility (intraclass coefficient correlation scores > 0.75) for RADs, CBTs and HSTs obtained from 5 different patients, observers were asked to repeat the analysis of the first 10 patients under the same circumstances. Values in millimetres represented each landmark in a table of Cartesian co-ordinates (x- and y-axes).
RESULTS: ANOVA showed significant reduction in variability levels after the PPC, and there were no differences among the methods of image acquisition. Repeated measures ANOVA indicated that the PPC accounted for reduction in variability levels in 14 of 20 landmarks.
CONCLUSIONS: The results suggest that a PPC has more influence than the type of image acquisition on variability of landmark identification based on two-dimensional cephalometric analysis. Cephalograms obtained from RAD or CBCT can be considered equivalent for clinical and experimental applications.

Entities:  

Mesh:

Year:  2010        PMID: 20841459      PMCID: PMC3520185          DOI: 10.1259/dmfr/31924248

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  35 in total

1.  Random errors in localization of landmarks in postero-anterior cephalograms.

Authors:  A E Athanasiou; R Miethke; A J Van Der Meij
Journal:  Br J Orthod       Date:  1999-12

2.  Reliability of landmark identification in cephalometric radiography acquired by a storage phosphor imaging system.

Authors:  Y-J Chen; S-K Chen; H-W Huang; C-C Yao; H-F Chang
Journal:  Dentomaxillofac Radiol       Date:  2004-09       Impact factor: 2.419

3.  Proposed reference point for 3-dimensional cephalometric analysis with cone-beam computerized tomography.

Authors:  Manuel O Lagravère; Paul W Major
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-11       Impact factor: 2.650

Review 4.  Accuracy of measurements and reliability of landmark identification with computed tomography (CT) techniques in the maxillofacial area: a systematic review.

Authors:  Leo Lou; Manuel O Lagravere; Sharon Compton; Paul W Major; Carlos Flores-Mir
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-10-27

5.  Comparison between conventional and cone-beam computed tomography-generated cephalograms.

Authors:  Paolo M Cattaneo; Christian Borgkvist Bloch; Dorte Calmar; Mette Hjortshøj; Birte Melsen
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-12       Impact factor: 2.650

6.  Assessment of linear and angular measurements on three-dimensional cone-beam computed tomographic images.

Authors:  Carla R Moreira; Marcelo A O Sales; Patricia M L Lopes; Marcelo G P Cavalcanti
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-04-22

7.  Reliability of cranial base measurements on lateral skull radiographs.

Authors:  H Arponen; H Elf; M Evälahti; J Waltimo-Sirén
Journal:  Orthod Craniofac Res       Date:  2008-11       Impact factor: 1.826

8.  Comparison of hand-traced and computerized cephalograms: landmark identification, measurement, and superimposition accuracy.

Authors:  Dustin Roden-Johnson; Jeryl English; Ronald Gallerano
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-04       Impact factor: 2.650

9.  Evaluation of the radiographic cephalometry learning process by a learning virtual object.

Authors:  Heraldo Luis Dias Silveira; Maria João Gomes; Heloísa Emilia Dias Silveira; Reni Raymundo Dalla-Bona
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-07       Impact factor: 2.650

10.  Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program.

Authors:  Danielle R Periago; William C Scarfe; Mazyar Moshiri; James P Scheetz; Anibal M Silveira; Allan G Farman
Journal:  Angle Orthod       Date:  2008-05       Impact factor: 2.079

View more
  5 in total

1.  Comparative study between conventional and cone beam CT-synthesized half and total skull cephalograms.

Authors:  G S Liedke; E L Delamare; M B Vizzotto; H L D da Silveira; J R Prietsch; V Dutra; H E D da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2012-02       Impact factor: 2.419

Review 2.  Cone beam computed tomography in paediatric dentistry: overview of recent literature.

Authors:  J K M Aps
Journal:  Eur Arch Paediatr Dent       Date:  2013-06

3.  Image-stitching artefacts and distortion in CCD-based cephalograms and their association with sensor type and head movement: ex vivo study.

Authors:  Olesya Svystun; Ann Wenzel; Lars Schropp; Rubens Spin-Neto
Journal:  Dentomaxillofac Radiol       Date:  2019-11-18       Impact factor: 2.419

4.  A study on the reproducibility of cephalometric landmarks when undertaking a three-dimensional (3D) cephalometric analysis.

Authors:  Natalia Zamora; José-María Llamas; Rosa Cibrián; José-Luis Gandia; Vanessa Paredes
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-07-01

5.  A fully deep learning model for the automatic identification of cephalometric landmarks.

Authors:  Young Hyun Kim; Chena Lee; Eun-Gyu Ha; Yoon Jeong Choi; Sang-Sun Han
Journal:  Imaging Sci Dent       Date:  2021-07-13
  5 in total