Arterial line filters ranked for gaseous micro-emboli separation performance: an in vitro study.

Jeffrey B Riley1.   

Abstract

UNLABELLED: Arterial line filters (ALFs) are arguably the most important component in the cardiopulmonary bypass circuit to protect the patient from gaseous macro- and micro-emboli (GME) originating in the perfusion circuit. The GME separating ability of 10 ALFs was ranked according to seven performance criteria. Ten ALFs rated between 20 and 43 microm were evaluated for flow resistance, the count, size, and volume of GME passed after a 10-mL room air bolus, and the ability to separate a high-count, 10- to 200-microm flowing distribution of GME. The Luna Innovations EDAC emboli detector was used to size, count, and sort GME. Three test trials were conducted for 3 each of the 10 filters. Performance criteria were correlated by regression analysis, statistically compared using analysis of variance, or ranked using non-parametric tests. Significance was set at 0.05. Weighting all seven test parameters equally, the most effective ALFs were the Cobe 21 and Gish 25-microm filters. The Pall LG-6 ranked more efficient than the Medtronic 20 and Dideco 27-microm filters. The Cobe 43, Terumo 40, Medtronic 38, Terumo 37, and Gish 40-microm filters were less effective as a group compared with the other filters. For the 10 filters, blood flow resistance was not correlated to rated pore size. Generally, the smaller the pore rating, the higher the GME separation ability rank, except for the leuko-reduction filter, which performed more effectively than other large pore filters. KEYWORDS: arterial line filter, gaseous microemboli, in vitro test.

Entities:  

Mesh:

Year:  2008        PMID: 18389662      PMCID: PMC4680652     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  15 in total

Review 1.  The use of leucocyte-depleting and conventional arterial line filters in cardiac surgery: a systematic review of clinical studies.

Authors:  D C Whitaker; J A Stygall; S P Newman; M J Harrison
Journal:  Perfusion       Date:  2001-11       Impact factor: 1.972

2.  The effect of leucocyte-depleting arterial line filters on cerebral microemboli and neuropsychological outcome following coronary artery bypass surgery.

Authors:  Donald C Whitaker; Stanton P Newman; Jan Stygall; Chris Hope-Wynne; Michael J G Harrison; Robin K Walesby
Journal:  Eur J Cardiothorac Surg       Date:  2004-02       Impact factor: 4.191

Review 3.  Bubbles and bypass: an update.

Authors:  Mark Kurusz; Bruce D Butler
Journal:  Perfusion       Date:  2004       Impact factor: 1.972

4.  The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli.

Authors:  Matthew J Norman; Joseph J Sistino; Jeffrey R Acsell
Journal:  J Extra Corpor Technol       Date:  2004-12

5.  Tubing spallation in extracorporeal circuits. An in vitro study using an electronic particle counter.

Authors:  J C Briceño; T M Runge
Journal:  Int J Artif Organs       Date:  1992-04       Impact factor: 1.595

Review 6.  An evidence-based review of the practice of cardiopulmonary bypass in adults: a focus on neurologic injury, glycemic control, hemodilution, and the inflammatory response.

Authors:  Kenneth G Shann; Donald S Likosky; John M Murkin; Robert A Baker; Yvon R Baribeau; Gordon R DeFoe; Timothy A Dickinson; Timothy J Gardner; Hilary P Grocott; Gerald T O'Connor; David J Rosinski; Frank W Sellke; Timothy W Willcox
Journal:  J Thorac Cardiovasc Surg       Date:  2006-08       Impact factor: 5.209

7.  In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs.

Authors:  Timothy A Dickinson; Jeffrey B Riley; Jeffrey C Crowley; Paul M Zabetakis
Journal:  J Extra Corpor Technol       Date:  2006-09

8.  Laboratory studies of the effect of Pall extracorporeal leucocyte filters LG6 and AV6 on patients undergoing coronary bypass grafts.

Authors:  P J Thurlow; L Doolan; R Sharp; M Sullivan; B Smith; L W Andersen
Journal:  Perfusion       Date:  1996-01       Impact factor: 1.972

9.  Serum S-100 protein concentration after cardiac surgery: a randomized trial of arterial line filtration.

Authors:  D P Taggart; K Bhattacharya; N Meston; S J Standing; J D Kay; R Pillai; P Johnssson; S Westaby
Journal:  Eur J Cardiothorac Surg       Date:  1997-04       Impact factor: 4.191

10.  The impact of microemboli during cardiopulmonary bypass on neuropsychological functioning.

Authors:  W Pugsley; L Klinger; C Paschalis; T Treasure; M Harrison; S Newman
Journal:  Stroke       Date:  1994-07       Impact factor: 7.914

View more
  19 in total

1.  In-vitro quantification of gaseous microemboli in two extracorporeal life support circuits.

Authors:  Jeffrey Burnside; Daniel Gomez; Thomas J Preston; Vincent F Olshove; Alistair Phillips
Journal:  J Extra Corpor Technol       Date:  2011-09

2.  Microbubble generation and transmission of medtronic's affinity hardshell venous reservoir and collapsible venous reservoir bag: an in-vitro comparison.

Authors:  Kieron C Potger; Darryl McMillan; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2011-09

3.  In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.

Authors:  Saifei Liu; Richard F Newland; Phillip J Tully; Sigrid C Tuble; Robert A Baker
Journal:  J Extra Corpor Technol       Date:  2011-09

4.  Evidence-based used, yet still controversial: the arterial filter.

Authors:  Filip De Somer
Journal:  J Extra Corpor Technol       Date:  2012-03

5.  Monitoring microemboli during cardiopulmonary bypass with the EDAC quantifier.

Authors:  John E Lynch; Christopher Wells; Tom Akers; Paul Frantz; Donna Garrett; M Lance Scott; Lisa Williamson; Barbara Agnew; John K Lynch
Journal:  J Extra Corpor Technol       Date:  2010-09

6.  Is the air handling capability of the quadrox D pump dependent within an ECMO circuit? An in vitro study.

Authors:  Martin C Gill; Hayden Dando; Dittmer John
Journal:  J Extra Corpor Technol       Date:  2010-09

7.  Air Transmission Comparison of the Affinity Fusion Oxygenator with an Integrated Arterial Filter to the Affinity NT Oxygenator with a Separate Arterial Filter.

Authors:  Kieron C Potger; Darryl McMillan; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2014-09

8.  Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2014-09

Review 9.  Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.

Authors:  Shigang Wang; Akif Undar
Journal:  J Extra Corpor Technol       Date:  2008-12

10.  The effects of pressure on gases in solution: possible insights to improve microbubble filtration for extracorporeal circulation.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2013-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.