The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli.

Matthew J Norman1, Joseph J Sistino, Jeffrey R Acsell.   

Abstract

During extracorporeal circulation, the patient's blood is siphoned into the extracorporeal circuit (ECC) by gravity or may be assisted kinetically or by vacuum. In all instances, negative pressure is generated in the venous line, which can cause entrainment of air into the ECC at the cannulation site. The typical ECC uses a venous reservoir, membrane oxygenator, and arterial line filter, which together aid in removal of air that has entered the venous line and minimize the transmission of gaseous microemboli to the patient. Recently, several manufacturers have introduced low prime ECCs with component configurations that differ from conventional ECCs, including the omission of a venous reservoir. These configuration changes may change the ability of the circuit to handle air and therefore their ability to minimize gaseous microemboli. The purpose of this study was to test the ability of new low prime ECCs to remove air introduced into the venous line and minimize gaseous microemboli from entering the patient's circulation. Using a model of CPB, air was introduced into the venous line of a low prime ECC and a conventional CPB circuit. The detection of the gaseous microemboli produced was monitored distal to the oxygenator by an ultrasonic emboli detector to determine if venous air was able to traverse the ECC at varying rates of air introduction and blood flow. Data was collected using data acquisition software loaded on a personal computer. Gaseous microemboli levels detected in the arterial line of the low prime ECC were 8 to 10 times higher than the microemboli levels detected in the conventional ECC at all blood flow rates. Every effort should be made to minimize and prevent air from being entrained in the venous line of a low prime CPB circuit to minimize the risk of arterial gaseous microemboli generation.

Entities:  

Mesh:

Year:  2004        PMID: 15679274

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  11 in total

1.  Monitoring microemboli during cardiopulmonary bypass with the EDAC quantifier.

Authors:  John E Lynch; Christopher Wells; Tom Akers; Paul Frantz; Donna Garrett; M Lance Scott; Lisa Williamson; Barbara Agnew; John K Lynch
Journal:  J Extra Corpor Technol       Date:  2010-09

2.  Is the air handling capability of the quadrox D pump dependent within an ECMO circuit? An in vitro study.

Authors:  Martin C Gill; Hayden Dando; Dittmer John
Journal:  J Extra Corpor Technol       Date:  2010-09

3.  Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2014-09

4.  Gaseous microemboli and the influence of microporous membrane oxygenators.

Authors:  Heinz-H Weitkemper; Bernd Oppermann; Andreas Spilker; Hermann-J Knobl; Reiner Körfer
Journal:  J Extra Corpor Technol       Date:  2005-09

5.  Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study.

Authors:  Andrea Hudacko; Alicia Sievert; Joseph Sistino
Journal:  J Extra Corpor Technol       Date:  2009-09

6.  Hyaluronan based heparin free coated open and closed extracorporeal circuits for high risk coronary revascularization.

Authors:  Serdar Gunaydin; Halil Ibrahim Ucar; Tanzer Serter; Kevin McCusker; Gokhan Ozcelik; Nevriye Salman; Ali Cem Yorgancioglu
Journal:  J Extra Corpor Technol       Date:  2010-12

7.  Application of Micropore Filter Technology: Exploring the Blood Flow Path in Arterial-Line Filters and Its Effect on Bubble Trapping Functions.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2017-03

8.  Arterial line filters ranked for gaseous micro-emboli separation performance: an in vitro study.

Authors:  Jeffrey B Riley
Journal:  J Extra Corpor Technol       Date:  2008-03

9.  Clinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population.

Authors:  Thomas J Preston; Daniel Gomez; Vincent F Olshove; Alistair Phillips; Mark Galantowicz
Journal:  J Extra Corpor Technol       Date:  2009-12

10.  Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study.

Authors:  Gerard J Myers; Cheri Voorhees; Rob Haynes; Bob Eke
Journal:  J Extra Corpor Technol       Date:  2009-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.