Literature DB >> 18389247

Cranial CT with 64-, 16-, 4- and single-slice CT systems-comparison of image quality and posterior fossa artifacts in routine brain imaging with standard protocols.

Birgit Ertl-Wagner1, Lara Eftimov, Jeffrey Blume, Roland Bruening, Christoph Becker, Jean Cormack, Hartmut Brueckmann, Maximilian Reiser.   

Abstract

Posterior fossa artifacts constitute a characteristic limitation of cranial CT. To identify practical benefits and drawbacks of newer CT systems with reduced collimation in routine cranial imaging, we aimed to investigate image quality, posterior fossa artifacts and parenchymal delineation in non-enhanced CT (NECT) with 1-, 4-, 16- and 64-slice scanners using standard scan protocols. We prospectively enrolled 25 consecutive patients undergoing NECT on a 64-slice CT. Three groups with 25 patients having undergone NECT on 1-, 4- and 16-slice CT machines were matched regarding age and sex. Standard routine CT parameters were used on each CT system with helical acquisition in the posterior fossa; the parameters varied regarding collimation and radiation dose. Three blinded readers independently assessed the cases regarding image quality, infra- and supratentorial artifacts and delineation of brain parenchymal structures on a five-point ordinal scale. Reading orders were randomized. A proportional odds model that accounted for the correlated nature of the data was fit using generalized estimating equations. Posterior fossa artifacts were significantly reduced, and the delineation of infratentorial brain structures was significantly improved with the thinner collimation used for the newer CT systems (p<0.001). No significant differences were observed for midbrain structures (p>0.5). The thinner collimation available on modern CT systems leads to reduced posterior fossa artifacts and to a better delineation of brain parenchyma in the posterior fossa.

Entities:  

Mesh:

Year:  2008        PMID: 18389247     DOI: 10.1007/s00330-008-0937-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  15 in total

1.  Performance evaluation of a multi-slice CT system.

Authors:  C H McCollough; F E Zink
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Subsecond multi-slice computed tomography: basics and applications.

Authors:  K Klingenbeck-Regn; S Schaller; T Flohr; B Ohnesorge; A F Kopp; U Baum
Journal:  Eur J Radiol       Date:  1999-08       Impact factor: 3.528

3.  Stair-step artifacts with single versus multiple detector-row helical CT.

Authors:  D Fleischmann; G D Rubin; D S Paik; S Y Yen; P R Hilfiker; C F Beaulieu; S Napel
Journal:  Radiology       Date:  2000-07       Impact factor: 11.105

4.  Cranial CT artifacts and gantry angulation.

Authors:  C Rozeik; O Kotterer; J Preiss; M Schütz; W Dingler; H K Deininger
Journal:  J Comput Assist Tomogr       Date:  1991 May-Jun       Impact factor: 1.826

Review 5.  Performance evaluation of a 64-slice CT system with z-flying focal spot.

Authors:  T Flohr; K Stierstorfer; R Raupach; S Ulzheimer; H Bruder
Journal:  Rofo       Date:  2004-12

Review 6.  Multi-detector row CT systems and image-reconstruction techniques.

Authors:  Thomas G Flohr; Stefan Schaller; Karl Stierstorfer; Herbert Bruder; Bernd M Ohnesorge; U Joseph Schoepf
Journal:  Radiology       Date:  2005-04-15       Impact factor: 11.105

7.  Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot.

Authors:  T G Flohr; K Stierstorfer; S Ulzheimer; H Bruder; A N Primak; C H McCollough
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

8.  Gantry angulation in brain CT: dosage implications, effect on posterior fossa artifacts, and current international practice.

Authors:  L J Yeoman; L Howarth; A Britten; A Cotterill; E J Adam
Journal:  Radiology       Date:  1992-07       Impact factor: 11.105

9.  Image quality of multisection CT of the brain: thickly collimated sequential scanning versus thinly collimated spiral scanning with image combining.

Authors:  M van Straten; H W Venema; C B L M Majoie; N J M Freling; C A Grimbergen; G J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

10.  Multi-detector row CT artifacts that mimic disease.

Authors:  Dianna D Cody; Donna M Stevens; Lawrence E Ginsberg
Journal:  Radiology       Date:  2005-07-29       Impact factor: 11.105

View more
  5 in total

1.  Effective dose evaluation of multidetector CT examinations: influence of the ICRP recommendation in 2007.

Authors:  Kosuke Matsubara; Kichiro Koshida; Masayuki Suzuki; Tetsunori Shimono; Tomoyuki Yamamoto; Osamu Matsui
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

2.  Hyperdense basilar artery sign-a reliable sign of basilar artery occlusion.

Authors:  Lara Connell; Inga Katharina Koerte; Ruediger Paul Laubender; Dominik Morhard; Jennifer Linn; Hans Christoph Becker; Maximilian Reiser; Hartmut Brueckmann; Birgit Ertl-Wagner
Journal:  Neuroradiology       Date:  2011-05-17       Impact factor: 2.804

3.  Improved delineation of arteries in the posterior fossa of the brain by model-based iterative reconstruction in volume-rendered 3D CT angiography.

Authors:  H Machida; H Takeuchi; I Tanaka; R Fukui; Y Shen; E Ueno; S Suzuki; X-Z Lin
Journal:  AJNR Am J Neuroradiol       Date:  2013-01-04       Impact factor: 3.825

4.  Alternative oblique head CT scanning technique reduces bone artifact and improves interpretability of brainstem anatomy.

Authors:  Sam Kampondeni; Gretchen L Birbeck; Robert J Oostveen; Colleen Hammond; Michael J Potchen
Journal:  Neurol Int       Date:  2010-06-21

Review 5.  Cerebellum and neurodegenerative diseases: Beyond conventional magnetic resonance imaging.

Authors:  Enricomaria Mormina; Maria Petracca; Giulia Bommarito; Niccolò Piaggio; Sirio Cocozza; Matilde Inglese
Journal:  World J Radiol       Date:  2017-10-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.