Literature DB >> 18383253

Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosis.

Niranjan Balu1, Baocheng Chu, Thomas S Hatsukami, Chun Yuan, Vasily L Yarnykh.   

Abstract

PURPOSE: To compare two- (2D) and three-dimensional (3D) black-blood imaging methods for morphological measurements of the carotid artery wall and atherosclerotic plaque.
MATERIALS AND METHODS: A total of 18 subjects with 50% to 79% carotid stenosis were scanned with 2D (2-mm slice thickness) and 3D (1-mm/0.5-mm actual/interpolated slice thickness) T1-weighted fast spin-echo (FSE) black-blood imaging sequences with double inversion-recovery (DIR) blood suppression. Morphological measurements (lumen area, wall area, vessel area, mean wall thickness, and maximal wall thickness), signal-to-noise ratio (SNR) in the wall and lumen, and wall-lumen contrast-to-noise ratio (CNR) were compared between 2D and 3D images. The effect of improved slice resolution in 3D imaging was evaluated for visualization of small plaque components.
RESULTS: Lumen SNR (P = 0.16), wall SNR (P = 0.65), and CNR (P = 0.94) were comparable between 2D/3D. There was no difference in average lumen area (P = 0.16), average wall area (P = 0.99), average vessel area (P = 0.0.58), mean wall thickness (P = 0.09), and maximum wall thickness (P = 0.06) between 2D/3D. Distributions of small plaque components such as calcification were better characterized by the 3D acquisition. There was a higher sensitivity to motion artifacts with 3D imaging, resulting in three examinations with low image quality.
CONCLUSION: 2D and 3D protocols provided comparable morphometric measurements of the carotid artery. The major advantage of 3D imaging is improved small plaque component visualization, while the 2D technique provides higher reliability for image quality. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18383253      PMCID: PMC2830087          DOI: 10.1002/jmri.21282

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  20 in total

1.  Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging.

Authors:  J G Pipe
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.

Authors:  R M Botnar; W Y Kim; P Börnert; M Stuber; E Spuentrup; W J Manning
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

3.  Assessing intrarater, interrater and test-retest reliability of continuous measurements.

Authors:  Valentin Rousson; Theo Gasser; Burkhardt Seifert
Journal:  Stat Med       Date:  2002-11-30       Impact factor: 2.373

4.  Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement.

Authors:  Lindsey A Crowe; Peter Gatehouse; Guang Zhong Yang; Raad H Mohiaddin; Anitha Varghese; Clare Charrier; Jennifer Keegan; David N Firmin
Journal:  J Magn Reson Imaging       Date:  2003-05       Impact factor: 4.813

5.  MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results.

Authors:  Cedric M J de Bazelaire; Guillaume D Duhamel; Neil M Rofsky; David C Alsop
Journal:  Radiology       Date:  2004-03       Impact factor: 11.105

6.  Serial MRI of carotid plaque burden: influence of subject repositioning on measurement precision.

Authors:  Niranjan Balu; William S Kerwin; Baocheng Chu; Fei Liu; Chun Yuan
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

7.  Signal-to-noise measurements in magnitude images from NMR phased arrays.

Authors:  C D Constantinides; E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

8.  Black blood MR angiography using multislab three-dimensional TI-weighted turbo spin-echo technique: imaging of intracranial circulation.

Authors:  E R Melhem; H Jara; E K Yucel
Journal:  AJR Am J Roentgenol       Date:  1997-11       Impact factor: 3.959

9.  Analysis of the measurement precision of arterial lumen and wall areas using high-resolution MRI.

Authors:  X Kang; N L Polissar; C Han; E Lin; C Yuan
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

10.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

View more
  33 in total

1.  Prospective self-gating for swallowing motion: a feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo.

Authors:  Zhaoyang Fan; Sven Zuehlsdorff; Xin Liu; Debiao Li
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Assessment of carotid stenosis using three-dimensional T2-weighted dark blood imaging: Initial experience.

Authors:  Georgeta Mihai; Marshall W Winner; Subha V Raman; Sanjay Rajagopalan; Orlando P Simonetti; Yiu-Cho Chung
Journal:  J Magn Reson Imaging       Date:  2011-12-06       Impact factor: 4.813

3.  Carotid plaque signal differences among four kinds of T1-weighted magnetic resonance imaging techniques: a histopathological correlation study.

Authors:  Ayumi Saito; Makoto Sasaki; Kuniaki Ogasawara; Masakazu Kobayashi; Jiro Hitomi; Shinsuke Narumi; Hideki Ohba; Mao Yamaguchi; Kohsuke Kudo; Yasuo Terayama
Journal:  Neuroradiology       Date:  2012-03-17       Impact factor: 2.804

4.  Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts.

Authors:  Frank J Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda Whitmore; Marie Gerhard-Herman; Nichole Wake; Tianxi Cai; Qian Zhou; Michael S Conte; Mark A Creager; Robert V Mulkern
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-24       Impact factor: 2.357

5.  Carotid intima-media thickness and distensibility measured by MRI at 3 T versus high-resolution ultrasound.

Authors:  Andreas Harloff; Timo Zech; Alex Frydrychowicz; Martin Schumacher; Joachim Schöllhorn; Jürgen Hennig; Cornelius Weiller; Michael Markl
Journal:  Eur Radiol       Date:  2009-02-13       Impact factor: 5.315

6.  Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

Authors:  Yibin Xie; Qi Yang; Guoxi Xie; Jianing Pang; Zhaoyang Fan; Debiao Li
Journal:  Magn Reson Med       Date:  2015-07-08       Impact factor: 4.668

7.  Registration of dynamic contrast-enhanced MRI of the common carotid artery using a fixed-frame template-based squared-difference method.

Authors:  Sarayu Ramachandran; Claudia Calcagno; Venkatesh Mani; Philip M Robson; Zahi A Fayad
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

8.  Predicting carotid plaque characteristics using quantitative color-coded T1-weighted MR plaque imaging: correlation with carotid endarterectomy specimens.

Authors:  S Narumi; M Sasaki; H Ohba; K Ogasawara; M Kobayashi; T Natori; J Hitomi; H Itagaki; T Takahashi; Y Terayama
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-03       Impact factor: 3.825

Review 9.  Three-Dimensional Carotid Plaque MR Imaging.

Authors:  Chun Yuan; Dennis L Parker
Journal:  Neuroimaging Clin N Am       Date:  2015-10-19       Impact factor: 2.264

10.  Variations in atherosclerosis and remodeling patterns in aorta and carotids.

Authors:  Katsumi Hayashi; Venkatesh Mani; Ajay Nemade; Silvia Aguiar; John E Postley; Valentin Fuster; Zahi A Fayad
Journal:  J Cardiovasc Magn Reson       Date:  2010-03-05       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.