Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement.

Lindsey A Crowe1, Peter Gatehouse, Guang Zhong Yang, Raad H Mohiaddin, Anitha Varghese, Clare Charrier, Jennifer Keegan, David N Firmin.   

Abstract

PURPOSE: To use a volume-selective 3D turbo spin echo (TSE) technique to image the carotid artery wall and measure distensibility.
MATERIALS AND METHODS: A high-resolution volume-selective 3D TSE sequence has been developed. Volume selection is accomplished by orthogonal gradients for the 90 degrees and 180 degrees excitations and allows a 3D volume of vessel wall to be imaged in a relatively short time. The technique has been developed to allow imaging at any defined phase of the cardiac cycle so that the vascular function and distensibility can be studied.
RESULTS: Scan efficiency is increased by the reduced phase encode field of view (FOV) (k(y) steps) by the use of selective volume excitation. Significantly more slices (k(z) phase encode steps) for vessel coverage can be acquired with the same scan time as that of the conventional sequence while maintaining signal-to-noise ratio (SNR) levels. The practical value of the technique was demonstrated on 10 normal subjects with high-resolution vessel distensibility measurements of the carotid arteries.
CONCLUSION: A volume-selective TSE method has been used for carotid artery wall imaging and measurement of distensibility in normal subjects. Larger coverage of the vessel, and therefore more information for clinical diagnostics, was achieved with the same overall scan time with an SNR comparable to that of 2D full FOV images. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Year:  2003        PMID: 12720267     DOI: 10.1002/jmri.10294

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  28 in total

1.  Prospective self-gating for swallowing motion: a feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo.

Authors:  Zhaoyang Fan; Sven Zuehlsdorff; Xin Liu; Debiao Li
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Free-breathing inner-volume black-blood imaging of the human heart using two-dimensionally selective local excitation at 3 T.

Authors:  Khaled Z Abd-Elmoniem; Christoph Barmet; Matthias Stuber
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

3.  The role of cardiovascular magnetic resonance in the non-invasive imaging of the atherosclerotic plaque.

Authors:  Anitha Varghese; Marcus Ellington; Guang Zhong Yang; Dudley J Pennell
Journal:  Int J Cardiovasc Imaging       Date:  2003-10       Impact factor: 2.357

4.  Carotid plaque signal differences among four kinds of T1-weighted magnetic resonance imaging techniques: a histopathological correlation study.

Authors:  Ayumi Saito; Makoto Sasaki; Kuniaki Ogasawara; Masakazu Kobayashi; Jiro Hitomi; Shinsuke Narumi; Hideki Ohba; Mao Yamaguchi; Kohsuke Kudo; Yasuo Terayama
Journal:  Neuroradiology       Date:  2012-03-17       Impact factor: 2.804

5.  Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts.

Authors:  Frank J Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda Whitmore; Marie Gerhard-Herman; Nichole Wake; Tianxi Cai; Qian Zhou; Michael S Conte; Mark A Creager; Robert V Mulkern
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-24       Impact factor: 2.357

6.  High-resolution 3D arteriography of chronic total peripheral occlusions using a T1-W turbo spin-echo sequence with inner-volume imaging.

Authors:  Smita Sampath; Amish N Raval; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

7.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.

Authors:  Dimitris Mitsouras; Robert V Mulkern; Frank J Rybicki
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

8.  Dual stack black blood carotid artery CMR at 3T: application to wall thickness visualization.

Authors:  Axel Bornstedt; Mathias Burgmaier; Vinzenz Hombach; Nikolaus Marx; Volker Rasche
Journal:  J Cardiovasc Magn Reson       Date:  2009-11-10       Impact factor: 5.364

9.  Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosis.

Authors:  Niranjan Balu; Baocheng Chu; Thomas S Hatsukami; Chun Yuan; Vasily L Yarnykh
Journal:  J Magn Reson Imaging       Date:  2008-04       Impact factor: 4.813

10.  In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

Authors:  Dimitris Mitsouras; Christopher D Owens; Michael S Conte; Hale Ersoy; Mark A Creager; Frank J Rybicki; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.