Literature DB >> 18351282

CT evaluation of cervical pedicle in a Chinese population for surgical application of transpedicular screw placement.

Zhu Ruofu1, Yang Huilin, Hu Xiaoyun, He Xishun, Tang Tiansi, Chen Liang, Li Xigong.   

Abstract

The lower cervical pedicle size differs between the Chinese and the non-Chinese population. Knowledge of pedicle dimensions and surface landmarks is crucial for the safe placement of screws, but few quantitative data concerning the lower cervical pedicle using CT scan and multiplanar reformations (MPR) in a Chinese population exist. The aim of this study was to evaluate lower cervical pedicle (C3-C7) dimensions in a Chinese population by computed axial tomography for surgical application. The dimensions of the pedicles (C3-C7) were determined in 60 patients from CT images of cervical spinal lesions. Measurements of pedicle height, width, pedicle axis length, effective length, and two angles of the pedicles, the distances from the projection point of the pedicle axis to the lateral edge of the lateral mass and to the inferior edge of the superior facet were measured. The smallest outer pedicle width was found at C3 among the female and C4 among the male. This measurement was significantly different between male and female patients in the outer pedicle width (P < 0.05; independent samples t test) at C3 and C4. The mean values of the outer pedicle width ranged from 5.4 to 6.7 mm in males, and 4.4 to 6.3 mm in females. The projection point of the pedicle axis in the lateral-superior area of the cervical lateral mass was the most important. There were significant correlations (P < 0.01; Kendall's W test) between the vertebral level and both pedicle angles (PTA and PSA). The smallest pedicle transverse angle was at C7 in males and females. The cervical spinal cord or vertebral artery may be at risk of injury if the angulation of the screw insert is over-medial or over-lateral in the transverse plane. Therefore, preoperative CT evaluation of pedicle transverse angle is very important. Considering the amount of variation among individuals, our data on CT measurements of pedicle in a Chinese population in conjunction with evaluation of the results of preoperative CT may enhance the safety of transpedicular screw fixation in the lower cervical spine.

Entities:  

Mesh:

Year:  2008        PMID: 18351282     DOI: 10.1007/s00276-008-0339-0

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  38 in total

1.  One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems.

Authors:  K Abumi; K Kaneda; Y Shono; M Fujiya
Journal:  J Neurosurg       Date:  1999-01       Impact factor: 5.115

2.  Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.

Authors:  Takeshi Sakamoto; Masashi Neo; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2004-11-15       Impact factor: 3.468

3.  Morphometric evaluation of subaxial cervical vertebrae for surgical application of transpedicular screw fixation.

Authors:  Mustafa Bozbuga; Adnan Ozturk; Zafer Ari; Kayihan Sahinoglu; Bulent Bayraktar; Aycicek Cecen
Journal:  Spine (Phila Pa 1976)       Date:  2004-09-01       Impact factor: 3.468

4.  Design of cervical pedicle locator and three-dimensional location of cervical pedicle.

Authors:  Guang-Ping Mao; Jian-Ning Zhao; Yu-Rong Wang; Jie-Shou Li; Yue-Xian Chen; Su-Jia Wu; Ni-Rong Bao
Journal:  Spine (Phila Pa 1976)       Date:  2005-05-01       Impact factor: 3.468

5.  Computerized tomographic measurement of the cervical pedicles diameter in a Malaysian population and the feasibility for transpedicular fixation.

Authors:  Mohd Imran Yusof; Liau Kai Ming; Mohd Shafie Abdullah; Abdul Halim Yusof
Journal:  Spine (Phila Pa 1976)       Date:  2006-04-15       Impact factor: 3.468

6.  Anatomical variations of the V2 segment of the vertebral artery.

Authors:  Michaël Bruneau; Jan F Cornelius; Vincent Marneffe; Michel Triffaux; Bernard George
Journal:  Neurosurgery       Date:  2006-07       Impact factor: 4.654

7.  [Clinical contrast of cervical pedicle screw fixation assisted by C-arm fluoroscopy or 3D navigation system].

Authors:  Wei Tian; Ya-jun Liu; Bo Liu; Qin Li; Lin Hu; Zhi-yu Li; Qiang Yuan
Journal:  Zhonghua Wai Ke Za Zhi       Date:  2006-10-15

8.  Morphologic characteristics of human cervical pedicles.

Authors:  E E Karaikovic; M D Daubs; R W Madsen; R W Gaines
Journal:  Spine (Phila Pa 1976)       Date:  1997-03-01       Impact factor: 3.468

9.  Biomechanical evaluation of methods of posterior stabilization of the spine and posterior lumbar interbody arthrodesis for lumbosacral isthmic spondylolisthesis. A calf-spine model.

Authors:  O Shirado; T A Zdeblick; P C McAfee; K E Warden
Journal:  J Bone Joint Surg Am       Date:  1991-04       Impact factor: 5.284

10.  Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine.

Authors:  Ralph Kothe; Wolfgang Rüther; Erich Schneider; Berend Linke
Journal:  Spine (Phila Pa 1976)       Date:  2004-09-01       Impact factor: 3.468

View more
  20 in total

Review 1.  Ethnic differences in pedicle and bony spinal canal dimensions calculated from computed tomography of the cervical spine: a review of the English-language literature.

Authors:  Masaaki Chazono; Takaaki Tanaka; Yoshio Kumagae; Tomoaki Sai; Keishi Marumo
Journal:  Eur Spine J       Date:  2012-04-19       Impact factor: 3.134

2.  Assessment of the morpho-densitometric parameters of the lumbar pedicles in osteoporotic and control women undergoing routine abdominal MDCT examinations.

Authors:  Antonios E Papadakis; Apostolos H Karantanas; Giorgos Papadokostakis; John Damilakis
Journal:  J Bone Miner Metab       Date:  2010-10-26       Impact factor: 2.626

3.  Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation.

Authors:  Sourabh Chachan; Hamid Rahmatullah Bin Abd Razak; Wee Lim Loo; John Carson Allen; Dinesh Shree Kumar
Journal:  Eur Spine J       Date:  2018-04-12       Impact factor: 3.134

4.  Reformatted computed tomographic evaluation of the thoracic pedicle in a Chinese population for the surgical application of transpedicular screw placement.

Authors:  Yuchun Chen; Jican Zeng; Jitian Guan; Yuelin Guo; Xinjia Wang; Guanfeng Yao; Weidong Wang; Weili Qi; Kangmei Kong
Journal:  Surg Radiol Anat       Date:  2009-11-17       Impact factor: 1.246

5.  Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae.

Authors:  Dong-Ho Lee; Sung-Woo Lee; Suk Jung Kang; Chang Ju Hwang; Nam Heun Kim; Ju-Yul Bae; Yung-Tae Kim; Choon Sung Lee; K Daniel Riew
Journal:  Eur Spine J       Date:  2011-04-09       Impact factor: 3.134

6.  Morphometry of typical cervical vertebrae on dry bones and CT scan and its implications in transpedicular screw placement surgery.

Authors:  Richa Gupta; Kanchan Kapoor; Anshu Sharma; Suman Kochhar; Rajeev Garg
Journal:  Surg Radiol Anat       Date:  2012-09-09       Impact factor: 1.246

7.  Computed tomographic morphometric analysis of cervical pedicles in a multi-ethnic Asian population and relevance to subaxial cervical pedicle screw fixation.

Authors:  Thangaraj Munusamy; Ady Thien; Mark Gerad Anthony; Ramesh Bakthavachalam; Shree Kumar Dinesh
Journal:  Eur Spine J       Date:  2014-08-26       Impact factor: 3.134

8.  Complications associated with thoracic pedicle screws in spinal deformity.

Authors:  Gang Li; Guohua Lv; Peter Passias; Michal Kozanek; Umesh S Metkar; Zhongjun Liu; Kirkham B Wood; Lubos Rehak; Youwen Deng
Journal:  Eur Spine J       Date:  2010-03-17       Impact factor: 3.134

9.  CT evaluation of upper thoracic spine for surgical application of transarticular screw placement.

Authors:  Yang Yu; Ning Xie; Bin Ni; Kai Liu; Qunfeng Guo; Jian Yang; Zhuangchen Zhu; Junsheng Luo
Journal:  Eur Spine J       Date:  2011-11-16       Impact factor: 3.134

10.  Computerized Tomography-Based Morphometric Analysis of Subaxial Cervical Spine Pedicle in Asymptomatic Indian Population.

Authors:  Kamran Farooque; Rahul Yadav; Buddhadev Chowdhury; Shivanand Gamanagatti; Atin Kumar; Pradeep Kumar Meena
Journal:  Int J Spine Surg       Date:  2018-08-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.