Literature DB >> 22086539

CT evaluation of upper thoracic spine for surgical application of transarticular screw placement.

Yang Yu1, Ning Xie, Bin Ni, Kai Liu, Qunfeng Guo, Jian Yang, Zhuangchen Zhu, Junsheng Luo.   

Abstract

INTRODUCTION: Although pedicle screw fixation has been increasingly used in the upper thoracic spine in recent years, controversies exist about the safety and complications such as nerve or vascular intrusion associated with the technique. In this study, an alternative method of transarticular screw fixation was validated.
MATERIALS AND METHODS: Morphometric analysis was performed on computed tomography (CT) scans of the upper thoracic zygapophysial joints of C7, T1, T2 and T3 in 20 male and 20 female patients in the axial and sagittal planes. The degree of screw angulation was recorded in the sagittal and axial planes and the screw length was measured at the spinal level from C7 to T3.
RESULTS: The smallest medial-lateral diameter and anterior-posterior diameter of IAP was found at T3 in the female patients and C7 in the male patients. The screw trajectory length ranged from 14.9 to 20.5 mm in all patients. All the above measurements were significantly different between male and female patients at all levels (P < 0.05). The mean value of screw trajectory angle was 19.3°-20.1° in the axial plane and 44.3°-45.7° in the sagittal plane. There was no statistically significant difference (P > 0.05) between male and female patients in the axial and sagittal angles.
CONCLUSION: The morphometric data of C7-T3 zygapophysial joints indicate the suitable screw diameter and screw length for this technique. Transarticular screw fixation proved to be a potentially safe alternative to pedicle screw fixation in this region.

Entities:  

Mesh:

Year:  2011        PMID: 22086539      PMCID: PMC3366145          DOI: 10.1007/s00586-011-2067-0

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  21 in total

1.  The anatomic relation of lateral mass screws to the spinal nerves. A comparison of the Magerl, Anderson, and An techniques.

Authors:  R Xu; S P Haman; N A Ebraheim; R A Yeasting
Journal:  Spine (Phila Pa 1976)       Date:  1999-10-01       Impact factor: 3.468

2.  A biomechanical comparison of facet screw fixation and pedicle screw fixation: effects of short-term and long-term repetitive cycling.

Authors:  Lisa A Ferrara; Jessica L Secor; Byung-Ho Jin; Andrew Wakefield; Serkan Inceoglu; Edward C Benzel
Journal:  Spine (Phila Pa 1976)       Date:  2003-06-15       Impact factor: 3.468

3.  Biomechanical evaluation of cervical lateral mass fixation: a comparison of the Roy-Camille and Magerl screw techniques.

Authors:  Cédric Barrey; Patrick Mertens; Claude Rumelhart; François Cotton; Jérôme Jund; Gilles Perrin
Journal:  J Neurosurg       Date:  2004-03       Impact factor: 5.115

4.  A biomechanical comparison of a novel thoracic screw fixation method: transarticular screw fixation vs traditional pedicle screw fixation.

Authors:  Yang Yu; Ning Xie; Shaohua Song; Wei Zhang; Qunfeng Guo; Bin Ni; Junsheng Luo
Journal:  Neurosurgery       Date:  2011-12       Impact factor: 4.654

5.  Clinical and radiological results after parapedicular screw fixation of the thoracic spine.

Authors:  Vassilios I Vougioukas; Johannes Weber; Kai M Scheufler
Journal:  J Neurosurg Spine       Date:  2005-10

6.  CT evaluation of cervical pedicle in a Chinese population for surgical application of transpedicular screw placement.

Authors:  Zhu Ruofu; Yang Huilin; Hu Xiaoyun; He Xishun; Tang Tiansi; Chen Liang; Li Xigong
Journal:  Surg Radiol Anat       Date:  2008-03-20       Impact factor: 1.246

7.  Quantitative anatomy of subaxial cervical lateral mass: an analysis of safe screw lengths for Roy-Camille and magerl techniques.

Authors:  Brian D Stemper; Satyajit V Marawar; Narayan Yoganandan; Barry S Shender; Raj D Rao
Journal:  Spine (Phila Pa 1976)       Date:  2008-04-15       Impact factor: 3.468

8.  Transfacet screw placement for posterior fixation of C-7.

Authors:  Eric M Horn; Nicholas Theodore; Neil R Crawford; Nicholas C Bambakidis; Volker K H Sonntag
Journal:  J Neurosurg Spine       Date:  2008-08

9.  Three-dimensional stabilization provided by the external spinal fixator compared to two internal fixation devices: a biomechanical in vitro flexibility study.

Authors:  Teija Lund; Thomas Nydegger; Gabor Rathonyi; Lutz-Peter Nolte; Dietrich Schlenzka; Thomas R Oxland
Journal:  Eur Spine J       Date:  2003-03-01       Impact factor: 3.134

10.  Morphometric and volumetric analysis of the lateral masses of the lower cervical spine.

Authors:  Kalil G Abdullah; Michael P Steinmetz; Thomas E Mroz
Journal:  Spine (Phila Pa 1976)       Date:  2009-06-15       Impact factor: 3.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.