Small fields: nonequilibrium radiation dosimetry.

Indra J Das1, George X Ding, Anders Ahnesjö.   

Abstract

Advances in radiation treatment with beamlet-based intensity modulation, image-guided radiation therapy, and stereotactic radiosurgery (including specialized equipments like CyberKnife, Gamma Knife, tomotherapy, and high-resolution multileaf collimating systems) have resulted in the use of reduced treatment fields to a subcentimeter scale. Compared to the traditional radiotherapy with fields > or =4 x 4 cm2, this can result in significant uncertainty in the accuracy of clinical dosimetry. The dosimetry of small fields is challenging due to nonequilibrium conditions created as a consequence of the secondary electron track lengths and the source size projected through the collimating system that are comparable to the treatment field size. It is further complicated by the prolonged electron tracks in the presence of low-density inhomogeneities. Also, radiation detectors introduced into such fields usually perturb the level of disequilibrium. Hence, the dosimetric accuracy previously achieved for standard radiotherapy applications is at risk for both absolute and relative dose determination. This article summarizes the present knowledge and gives an insight into the future procedures to handle the nonequilibrium radiation dosimetry problems. It is anticipated that new miniature detectors with controlled perturbations and corrections will be available to meet the demand for accurate measurements. It is also expected that the Monte Carlo techniques will increasingly be used in assessing the accuracy, verification, and calculation of dose, and will aid perturbation calculations of detectors used in small and highly conformal radiation beams. rican Association of Physicists in Medicine.

Mesh:

Year:  2008        PMID: 18293576     DOI: 10.1118/1.2815356

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  117 in total

1.  PRESAGE 3D dosimetry accurately measures Gamma Knife output factors.

Authors:  Slade J Klawikowski; James N Yang; John Adamovics; Geoffrey S Ibbott
Journal:  Phys Med Biol       Date:  2014-11-04       Impact factor: 3.609

2.  Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques.

Authors:  Joseph Newton; Mark Oldham; Andrew Thomas; Yifan Li; John Adamovics; David G Kirsch; Shiva Das
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  Investigation of thermal and temporal responses of ionization chambers in radiation dosimetry.

Authors:  Hussein AlMasri; Akira Funyu; Yasumasa Kakinohana; Sadayuki Murayama
Journal:  Radiol Phys Technol       Date:  2012-04-01

4.  Comparison of total MU and segment areas in VMAT and step-and-shoot IMRT plans.

Authors:  Motohiro Kawashima; Shuichi Ozawa; Akihiro Haga; Akira Sakumi; Chie Kurokawa; Satoru Sugimoto; Kumiko Karasawa; Keiichi Nakagawa; Keisuke Sasai
Journal:  Radiol Phys Technol       Date:  2012-07-01

5.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

6.  Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations.

Authors:  Lilie L W Wang; Sam Beddar
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  Simulation of the precision limits of plastic scintillation detectors using optimal component selection.

Authors:  Frédéric Lacroix; Luc Beaulieu; Louis Archambault; A Sam Beddar
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

8.  Estimation of focal and extra-focal radiation profiles based on Gaussian modeling in medical linear accelerators.

Authors:  Shigeo Anai; Hidetaka Arimura; Katsumasa Nakamura; Fujio Araki; Takaomi Matsuki; Hideki Yoshikawa; Satoshi Yoshidome; Yoshiyuki Shioyama; Hiroshi Honda; Nobuo Ikeda
Journal:  Radiol Phys Technol       Date:  2011-03-24

9.  Investigating the Electronic Portal Imaging Device for Small Radiation Field Measurements.

Authors:  Arpita Agarwal; Nikhil Rastogi; K J Maria Das; S A Yoganathan; D Udayakumar; Shaleen Kumar
Journal:  J Med Phys       Date:  2017 Apr-Jun

Review 10.  Monte Carlo systems used for treatment planning and dose verification.

Authors:  Lorenzo Brualla; Miguel Rodriguez; Antonio M Lallena
Journal:  Strahlenther Onkol       Date:  2016-11-25       Impact factor: 3.621

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.