Investigation of thermal and temporal responses of ionization chambers in radiation dosimetry.

Hussein AlMasri1, Akira Funyu, Yasumasa Kakinohana, Sadayuki Murayama.   

Abstract

The ionization chamber is a primary dosimeter that is used in radiation dosimetry. Generally, the ion chamber response requires temperature/pressure correction according to the ideal gas law. However, this correction does not consider the thermal volume effect of chambers. The temporal and thermal volume effects of various chambers (CC01, CC13, NACP parallel-plate, PTW) with different wall and electrode materials have been studied in a water phantom. Measurements were done after heating the water with a suitable heating system, and chambers were submerged for a sufficient time to allow for temperature equilibrium. Temporal results show that all chambers equilibrate quickly in water. The equilibration time was between 3 and 5 min for all chambers. Thermal results show that all chambers expanded in response to heating except for the PTW, which contracted. This might be explained by the differences in the volumes of all chambers and also by the difference in wall material composition of PTW from the other chambers. It was found that the smallest chamber, CC01, showed the greatest expansion. The magnitude of the expansion was ~1, 0.8, and 0.9% for CC01, CC13, and parallel-plate chambers, respectively, in the temperature range of 295-320 K. The magnitude of the detected contraction was <0.3% for PTW in the same temperature range. For absolute dosimetry, it is necessary to make corrections for the ion chamber response, especially for small ion chambers like the CC01. Otherwise, room and water phantom temperatures should remain within a close range.

Entities:  

Mesh:

Year:  2012        PMID: 22467281     DOI: 10.1007/s12194-012-0151-8

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  7 in total

1.  Insulators for radiological instruments.

Authors:  J F FOWLER; F T FARMER
Journal:  Br J Radiol       Date:  1956-02       Impact factor: 3.039

2.  Thermal and temporal response of ionization chambers in radiation dosimetry.

Authors:  Indra J Das; Timothy C Zhu
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

3.  Small fields: nonequilibrium radiation dosimetry.

Authors:  Indra J Das; George X Ding; Anders Ahnesjö
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

4.  Equilibration of air temperature inside the thimble of a Farmer-type ion chamber.

Authors:  R C Tailor; C Chu; D S Followill; W F Hanson
Journal:  Med Phys       Date:  1998-04       Impact factor: 4.071

5.  About the rate of temperature changes in a thimble chamber.

Authors:  P H van der Giessen
Journal:  Radiother Oncol       Date:  1986-11       Impact factor: 6.280

6.  Pressure time-constants for 0.6 cm 3 Farmer ionization chambers.

Authors:  A Robinson
Journal:  Br J Radiol       Date:  1972-03       Impact factor: 3.039

7.  Ionization chamber response to a sudden change of ambient temperature in air, water, and polystyrene phantom.

Authors:  H Kubo
Journal:  Med Phys       Date:  1983 Sep-Oct       Impact factor: 4.071

  7 in total
  2 in total

1.  Quantification of the temperature equilibrium time of the cavity in parallel-plate-type ionization chambers by thermal analysis.

Authors:  Hiraku Fuse; Soma Hirota; Tatsuya Fujisaki; Shinji Abe; Kenji Yasue; Koichi Hanada; Fumihiro Tomita
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

2.  Quantifying temperature-equilibrium time using temperature analysis inside a Farmer ionization chamber.

Authors:  Hiraku Fuse; Tatsuya Fujisaki; Shinji Abe; Kenji Yasue; Satoshi Oyama
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.