Literature DB >> 9385290

Radiographic assessment of cup migration and wear after hip replacement.

T Ilchmann1.   

Abstract

Methods are needed for accurate measurement of acetabular cup migration and wear after hip replacement. The EBRA (Ein Bild Röntgen Analyse) method was recently introduced as computerized method for radiographic assessment of acetabular cup migration. In this study, various standard methods for measuring migration were evaluated and compared to radiostereometry (RSA), which has proved to be highly accurate. A subroutine for wear measurement was developed and added to the EBRA method. Of the standard methods, Nunn's method was the best for migration measurement and Livermore's the best for wear measurement. Measurements with EBRA were better than the standard methods. Pelvic tilt seemed to be the main source of error in measurements. The effect of pelvic tilt was evaluated experimentally. EBRA detected and excluded tilted radiographs, the errors of measurement being smaller with EBRA than with standard methods. The precision of the input procedure, repeated radiographic examination, the intra- and interobserver errors were assessed. Apart from the digital input of the data, EBRA was better than the standard methods. Normal values concerning acetabular cup migration and wear should be obtained from long-term surviving hip replacements, without radiographic signs of loosening. No method of measurement detected evidence of changes in the wear-rate and in migration over time. EBRA showed cold-flow in some cups, but did not provide additional information in the long-term. Nunn's method for migration measurements and Livermore's method for wear are recommended in clinical practice. EBRA is more accurate and should be used for studies of new implant designs that have passed the preclinical and, preferably, radiostereometric analysis. RSA is unsurpassed and is recommended for early clinical follow-up in a limited number of patients.

Entities:  

Mesh:

Year:  1997        PMID: 9385290     DOI: 10.1080/17453674.1997.11744768

Source DB:  PubMed          Journal:  Acta Orthop Scand Suppl        ISSN: 0300-8827


  6 in total

1.  Modes of failure of a threaded acetabular cup : a radiographic study with EBRA of 42 revised cups.

Authors:  Thomas Ilchmann; Severin Neher; Franz Maurer; Kuno Weise
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

2.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

3.  Surgical technique: Porous tantalum reconstruction for destructive nonprimary periacetabular tumors.

Authors:  Fazel A Khan; Peter S Rose; Michiro Yanagisawa; David G Lewallen; Franklin H Sim
Journal:  Clin Orthop Relat Res       Date:  2011-10-12       Impact factor: 4.176

4.  Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty: a pilot study.

Authors:  Bin Chen; Sheng-xiang Xiao; Peng-cheng Gu; Xiang-jin Lin
Journal:  J Zhejiang Univ Sci B       Date:  2010-09       Impact factor: 3.066

5.  Effectiveness of computer-navigated minimally invasive total hip surgery compared to conventional total hip arthroplasty: design of a randomized controlled trial.

Authors:  Inge H F Reininga; Robert Wagenmakers; Inge van den Akker-Scheek; A Dennis Stant; Johan W Groothoff; Sjoerd K Bulstra; Wiebren Zijlstra; Martin Stevens
Journal:  BMC Musculoskelet Disord       Date:  2007-01-11       Impact factor: 2.362

6.  Standard Transgluteal versus Minimal Invasive Anterior Approach in hip Arthroplasty: A Prospective, Consecutive Cohort Study.

Authors:  Thomas Ilchmann; Silke Gersbach; Lukas Zwicky; Martin Clauss
Journal:  Orthop Rev (Pavia)       Date:  2013-11-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.