Abstract

The two-dimensional position of markers in radiographs for Roentgen Stereophotogrammetric Analysis (RSA) is usually determined using a measuring table. The purpose of this study was to evaluate the reproducibility and the accuracy of a new RSA system using digitized radiographs and image-processing algorithms to determine the marker position in the radiographs. Four double-RSA examinations of a phantom and 18 RSA examinations from six patients included in different RSA-studies of knee prostheses were used to test the reproducibility and the accuracy of the system. The radiographs were scanned at 600 dpi resolution and 256 gray levels. The center of each of the tantalum-markers in the radiographs was calculated by the computer program from the contour of the marker with the use of an edge-detection software algorithm after the marker was identified on a PC monitor. The study showed that computer-based image analysis can be used in RSA-examinations. The advantages of using image-processing software in RSA are that the marker positions are determined in an objective manner, and that there is no need for a systematic manual identification of all the markers on the radiograph before the actual measurement.

Entities:  

Mesh:

Year:  1997        PMID: 9302627     DOI: 10.1016/s0021-9290(97)00060-2

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Three-dimensional point localisation in low-dose X-ray images using stereo-photogrammetry.

Authors:  T S Douglas; C L Vaughan; S M Wynne
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

2.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

3.  Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: an experimental study.

Authors:  Olof Sköldenberg; Magnus Odquist
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

4.  Effect of bioactive coating of the tibial component on migration pattern in uncemented total knee arthroplasty: a randomized RSA study of 14 knees presented according to new RSA-guidelines.

Authors:  M Therbo; B Lund; K-E Jensen; H M Schrøder
Journal:  J Orthop Traumatol       Date:  2008-05-10

5.  Development and validation of an automated and marker-free CT-based spatial analysis method (CTSA) for assessment of femoral hip implant migration: In vitro accuracy and precision comparable to that of radiostereometric analysis (RSA).

Authors:  Thierry Scheerlinck; Mathias Polfliet; Rudi Deklerck; Gert Van Gompel; Nico Buls; Jef Vandemeulebroucke
Journal:  Acta Orthop       Date:  2015-12-03       Impact factor: 3.717

  5 in total