Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Rami Madanat1, Tatu J Mäkinen, Hannu T Aro, Charles Bragdon, Henrik Malchau.   

Abstract

BACKGROUND AND
PURPOSE: Guidelines for standardization of radiostereometry (RSA) of implants were published in 2005 to facilitate comparison of outcomes between various research groups. In this systematic review, we determined how well studies have adhered to these guidelines.
METHODS: We carried out a literature search to identify all articles published between January 2000 and December 2011 that used RSA in the evaluation of hip or knee prosthesis migration. 2 investigators independently evaluated each of the studies for adherence to the 13 individual guideline items. Since some of the 13 points included more than 1 criterion, studies were assessed on whether each point was fully met, partially met, or not met.
RESULTS: 153 studies that met our inclusion criteria were identified. 61 of these were published before the guidelines were introduced (2000-2005) and 92 after the guidelines were introduced (2006-2011). The methodological quality of RSA studies clearly improved from 2000 to 2011. None of the studies fully met all 13 guidelines. Nearly half (43) of the studies published after the guidelines demonstrated a high methodological quality and adhered at least partially to 10 of the 13 guidelines, whereas less than one-fifth (11) of the studies published before the guidelines had the same methodological quality. Commonly unaddressed guideline items were related to imaging methodology, determination of precision from double examinations, and also mean error of rigid-body fitting and condition number cutoff levels.
INTERPRETATION: The guidelines have improved methodological reporting in RSA studies, but adherence to these guidelines is still relatively low. There is a need to update and clarify the guidelines for clinical hip and knee arthroplasty RSA studies.

Entities:  

Mesh:

Year:  2014        PMID: 24954489      PMCID: PMC4164860          DOI: 10.3109/17453674.2014.934187

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


Since the introduction of radiostereometry (RSA) in 1974, the method has continuously proven to be a valuable tool in the assessment of migration following hip and knee arthroplasty. Although the importance of a stepwise introduction of new orthopedic implants was presented in 1995 (Malchau 1995), only recently has it been fully acknowledged that deletion of some of these crucial steps can have catastrophic consequences (Kärrholm 2012). The phased or stepwise introduction process is based on the hypothesis that a more precise and careful evaluation of new implants will reduce the number of patients at risk of unexpected failures. There are 4 suggested steps to this process (Malchau 1995). The initial step involves preclinical implant testing. After this, the first clinical step consists of prospective randomized studies that use RSA. The second clinical step involves multicenter studies and the final step is composed of registry studies. The detection of early migration or accelerated wear using RSA are ways of predicting early implant failure, and are therefore important components of this stepwise introduction process (Kärrholm 2012). Although RSA would probably not have been able to forecast some of the problems related to the metal-on-metal articulation, it could have prevented the premature introduction of Boneloc cement. When Boneloc was introduced, the Norwegian Arthroplasty Register needed more than 1,000 patients before it could be proven to be an inferior cement based on a higher revision rate compared to regular bone cement (Havelin et al. 1995). Using RSA only, 30 patients were included in a study that—already after 6 months—showed that Boneloc-cemented implants were clearly less stable than those with conventional bone cement (Thanner et al. 1995). If Boneloc had been studied with RSA prior to being released onto the market, thousands of patients would have been spared from early revision. There are several other examples of poor orthopedic implants or materials that should have been tested with RSA prior to widespread release (Muirhead-Allwood 1998, Norton et al. 2002). In the past, many serious problems initially manifested as low-incidence events but only later proved to be the tip of the iceberg (Malchau et al. 2011). Despite the fact that the algorithm for introduction of new implant designs was established more than 15 years ago, many new and untested implants still appear on the market. The orthopedic community has acknowledged that the fast spread of undocumented new implants is no longer acceptable (Kärrholm 2012). With the increasing importance of RSA, it has also been recognized that reporting of RSA outcomes should be standardized. The guidelines for standardization of radiostereometry of implants were published in August 2005, to facilitate comparison of RSA outcomes reported from different centers (Valstar et al. 2005). In that paper, an appendix of 13 main items that should be used to account for the results of a clinical RSA study is outlined. Furthermore, since RSA is a highly technical method, the reliability and reproducibility of a study can only be assessed when all standardized output items have been adequately addressed. We investigated whether the RSA guidelines have resulted in improved methodological reporting in clinical RSA studies of hip and knee arthroplasty. We also assessed the overall level of adherence to each of the individual guidelines following their introduction.

Material and methods

We carried out a literature search using OVID Medline, the OVID Cochrane central register of controlled trials, and SCOPUS Embase to identify all articles published between January 2000 and December 2011 that used RSA in the evaluation of hip or knee prosthesis migration or wear. The search strategy included the following terms: radiostereometric analysis, radiostereometry, roentgen stereophotogrammetric analysis, RSA, hip, and knee. Only English language clinical studies with at least 2 follow-up time points were included. Case reports were excluded. Study identification was performed according to the PRISMA statement (Figure 1).
Figure 1.

PRISMA flow chart of study selection.

PRISMA flow chart of study selection. 2 investigators (RM and TJM) independently evaluated each of the studies for adherence to the 13 individual guideline points (Table 1). Since most of the 13 guideline points included more than 1 issue that needed to be addressed, the individual guidelines were divided into subcategories (A to D) to facilitate the evaluation process. Studies were then assessed on whether each guideline was fully met, partially met, or not met. Other information collected from the studies regarding publication were the name of the journal, geographical region based on first author (Nordic countries, rest of Europe, USA/Canada, Australia) and the year of publication. We also collected data on the main study question (whether the study assessed hip or knee arthroplasty migration or wear), study design (retrospective, prospective cohort, or RCT), the period of data collection, the percentage of patients for whom RSA was not successful, and the formula used to calculate confidence intervals. Disagreement was resolved by consensus.
Table 1.

List of the 13 guidelines and subcategories used to evaluate study adherence (adapted from Valstar et al. 2005)

Guideline number Subcategory
Guideline
1ATranslation units in millimeters
BRotation units in degrees
2AAccuracy presented
BPrecision presented
CMeasurement interval mentioned
DWindow of tolerance mentioned
3Type of calibration cage mentioned
4Fixed or portable X-ray sources used
5ASubject positioning described
BOrientation of global coordinate system presented
6AMethod of image acquisition stated
BScanner or system details mentioned
7ASoftware name mentioned
BSoftware version mentioned
8AMarker size mentioned
BMarker size validated (or manufacturer mentioned)
9RSA method mentioned (marker, model, etc.)
10ACutoff level for condition number noted
BCutoff level for mean error of rigid-body fitting noted
11ARigid-body fixed coordinate frames defined
BAngular rotation sequence mentioned if relevant
12APrecision determined using double examinations
BDouble examinations of all patients performed
13AAll 6 degrees of freedom reported
BPoint or segment motion used
CPoint(s) used to measure translation indicated
List of the 13 guidelines and subcategories used to evaluate study adherence (adapted from Valstar et al. 2005)

Results

153 studies that met our inclusion criteria were identified (Figure 1). 61 of these were published before the guidelines (2000 to 2005) and the remaining 92 after the guidelines (2006 to 2011). 96 studies evaluated hip arthroplasty and 57 studies evaluated knee arthroplasty. Most of the studies (121) used RSA to assess migration and 22 studies used RSA to evaluate wear. Only 10 studies used RSA to measure both wear and migration. Over half of the studies were randomized controlled trials (81 studies), the remainder consisted largely of prospective cohort studies (66 studies), and a few were retrospective studies (6 studies). None of the studies fully met all 13 guidelines. Only 7 studies published after the guidelines showed partial adherence to all guidelines. The highest number of guidelines fully met was 10 and this was achieved in 8 studies, all of which were published after the guidelines. Almost half of the studies published after the guidelines (43) showed partial adherence to 10 of 13 guidelines, and accordingly we selected this adherence level to mean high adherence. As expected, the methodological quality of the RSA studies published before the guidelines was low, with less than one-fifth (11) of the studies partially fulfilling 10 of 13 guideline items. The methodological quality of studies clearly improved from 2000 to 2011 (Figure 2). The proportion of studies with high adherence increased almost 3-fold when we compared the means of time periods before and after the guidelines. The annual number of publications included in the analysis varied from 6 to 26. The largest number of publications was from 2006, during which a special Radiostereometric Analysis in Orthopaedic Surgery symposium issue of Clinical Orthopaedics and Related Research was published.
Figure 2.

The annual numbers of hip and knee arthroplasty RSA studies published from 2000 to 2011 that met the inclusion criteria (bars) and the proportion of studies with high adherence (line). The RSA guidelines where published at the end of 2005.

The annual numbers of hip and knee arthroplasty RSA studies published from 2000 to 2011 that met the inclusion criteria (bars) and the proportion of studies with high adherence (line). The RSA guidelines where published at the end of 2005. Following introduction of the RSA guidelines, the items with highest adherence were guideline 1 (measurement units), 9 (RSA method), and 11 (rigid-body fixed coordinate frames and angular rotation sequence) whereas those with poorest adherence were 3 (type of calibration cage), 4 (fixed or portable X-ray source), 6 (image acquisition method and system details), and 10 (cutoff level for condition number or CN and mean error of rigid-body fitting or ME) (Figure 3). Guideline 2 (accuracy, precision, measurement interval, and window of tolerance) generally only had partial adherence. Although the level of precision was presented in 60 studies (65%), the level of accuracy was only mentioned in 12 studies (13%). The measurement interval was mentioned in all studies, but the window of tolerance was generally only mentioned for the postoperative examination and was usually a one-week window. Surprisingly, 35 studies did not mention the window of tolerance for any of the RSA examinations. Only 2 studies mentioned the window of tolerance for RSA examinations after the postoperative examination and used a 5–10% tolerance limit.
Figure 3.

Adherence of studies published after the guidelines to each of the 13 individual guideline items. The levels of adherence are presented in green (full adherence), yellow (partial adherence), and red (no adherence). Guidelines are presented left to right from highest to lowest adherence. The guideline number is given in parentheses.

Adherence of studies published after the guidelines to each of the 13 individual guideline items. The levels of adherence are presented in green (full adherence), yellow (partial adherence), and red (no adherence). Guidelines are presented left to right from highest to lowest adherence. The guideline number is given in parentheses. Most of the studies evaluated were from Nordic countries, and these also had the highest level of adherence to the RSA guidelines when compared to the other geographical regions (Table 2). Similarly, the majority of the studies were published in Acta Orthopaedica (Table 3).
Table 2.

Adherence of studies published during 2006–2011 to the RSA guidelines according to region of publication

Total no. of studiesNumber (%) of studies with high adherence a
Nordic countries b 5529 (53)
Rest of Europe c 218 (38)
USA/Canada93 (33)
Australia73 (43)

Partial or full adherence to at least 10 of 13 RSA guidelines.

Denmark, Finland, Norway, and Sweden.

Germany, Italy, the Netherlands, UK.

Table 3.

Adherence of studies published during 2006–2011 to the RSA guidelines according to journal

Total no. of studiesNo. of studies with high adherence a
Acta Orthopaedica239
Clinical Orthopaedics and
Related Research1812
Journal of Arthroplasty134
Journal of Bone and Joint
Surgery (British Volume)123
International Orthopaedics62
The Knee42
Other b 1611

Partial or full adherence to at least 10 of 13 RSA guidelines.

11 journals with 2 publications or less that met the inclusion criteria during the study period.

Adherence of studies published during 2006–2011 to the RSA guidelines according to region of publication Partial or full adherence to at least 10 of 13 RSA guidelines. Denmark, Finland, Norway, and Sweden. Germany, Italy, the Netherlands, UK. Adherence of studies published during 2006–2011 to the RSA guidelines according to journal Partial or full adherence to at least 10 of 13 RSA guidelines. 11 journals with 2 publications or less that met the inclusion criteria during the study period. The proportion of patients for whom RSA was not successful was difficult to extract from most of the studies, especially from studies that included patients with bilateral arthroplasty procedures. From the 75 studies published after the guidelines with available data, RSA was not successful in 8% of knee arthroplasty patients and in 12% of hip arthroplasty patients. Furthermore, there was no mention of how the confidence interval (CI)—and hence precision of the method—was calculated in 34 studies. The remaining studies that did report these data used heterogeneous but accepted methods for calculating the confidence interval, with some studies reporting the 99% CI while others used the 95% CI. More than half of the studies published from 2006 to 2011 clearly mentioned the time period of patient recruitment, but this information was lacking in 43 studies.

Discussion

The guidelines for standardization of radiostereometry of implants have clearly improved the methodological reporting in RSA studies during the last decade. Nevertheless, the overall level of adherence to the guidelines is still low. We believe that low adherence to some of the guidelines was due to oversight—or to the assumption that the reader is already aware of the methodological details. Examples of this include not mentioning the type of calibration cage, the image acquisition method, or whether a fixed or portable X-ray source was used. However, some guidelines such as the cutoff level for condition number and mean error of rigid-body fitting are more crucial to understanding of the validity of the results and consequently their clinical significance. Furthermore, the stability and distribution of RSA markers within a rigid body will influence the accuracy of the motion calculation and may affect the conclusions drawn from the study. Guideline 2 (accuracy, precision, measurement interval, and window of tolerance) generally only had partial adherence. Although the level of precision was presented in 65% of the studies published after the guidelines, double examinations of all patients were performed in only 18% of these. This raises the question of whether it is reasonable to demand this, or if it would be sufficient to perform double examinations on a random selection of subcohort of the patients in a study. Similarly, the level of accuracy was only mentioned in 13% of the studies published after 2005. It is also noteworthy that several studies used the term accuracy to mean clinical precision. The measurement of true RSA accuracy requires data from phantom studies and although this information is important, it is not as clinically relevant as precision data from double examinations, which define the true clinical accuracy. As expected, most of the RSA studies were from Nordic countries where the adherence to guidelines was also highest, probably for historical reasons. Journals with fewer RSA studies tended to have higher adherence. This could be due to more stringent enforcement during the peer review process, since the RSA method is less familiar to the reviewers of these journals. On the other hand, studies published in Clinical Orthopaedics and Related Research also showed a high level of adherence. This was clearly influenced by the RSA symposium issue published in 2006, which may have undergone a more stringent review process due to the special focus of the issue, and also as it was published soon after the guidelines. Some information that is currently not included in the RSA guidelines is the proportion of patients for whom RSA was not successful. We feel that these data are important for 2 reasons: firstly, because this information is crucial in understanding the clinical relevance of the data; and secondly, because this information is valuable to other researchers when planning similar studies. As model-based RSA is becoming more popular, it is necessary to also include parameters that give an indication of the quality of the data obtained. An example of this could be the difference value (DIF) that is used in MBRSA software (RSAcore, Leiden, the Netherlands), which is a surrogate for the difference of the actual implant contour and the virtual contour. Inclusion of such quality control parameters would further standardize new developments in the RSA methodology. The strengths of this systematic review include the large number of studies included (153) over a 12-year period. This enabled us to gain a general understanding of the trends in adherence over time. To our knowledge, this type of study has not been published previously. One limitation of the study is that no attempt was made to contact the authors of the papers. This might have allowed us to obtain more information about some aspects of guideline adherence that could not be assessed from the papers directly. On the other hand, our aim was to assess adherence to guidelines based on the information available from publications. Another limitation of the present study is that it only assessed hip and knee arthroplasty studies and excluded studies related to other applications such as spinal fusion or fracture studies. Although these other applications of RSA are also relevant, we decided to focus on the 2 main applications of RSA. In summary, RSA is important to ensure a safe yet effective stepwise introduction of new implants. New developments in RSA have enabled faster analysis and even measurement of marker-free implants. The RSA guidelines are an integral part of the methodology. Our study demonstrated that the guidelines have clearly had a positive effect on the methodological quality of RSA publications, but there is still room for improvement. The next step is to update, simplify, and clarify the guidelines and also promote their use in the peer review process. In future RSA publications, we suggest that an appendix, similar to the one shown in Table 4, be included in all future RSA publications.
Table 4.

Suggested presentation of standardized output for a clinical RSA study

Items relevant to the Materials and Methods section of the study
 Time period of patient recruitment
 Positioning of subject and calibration cage
 Orientation of the global coordinate system (consider a diagram)
 Rigid body fixed coordinate frames defined
 RSA method (marker-based, geometrical or model-based) and version of RSA software
 Units used for translation millimeters and the units for rotations degrees
 Measurement interval
 The points used to measure translation indicated (consider an x-ray or diagram)
 Translations and angular rotations with all six degrees of freedom if applicable
 Clinical precision
 Number of patients for whom RSA was not successful
Items to be mentioned in an appendix of the study
 Accuracy of the arrangement (if phantom studies have been performed)
 Size and manufacturer of RSA markers
 Type and manufacturer of calibration cage
 Fixed or portable x-ray sources and manufacturer
 Radiographic exposure settings (kV and mAs)
 Window of tolerance for both postoperative and follow-up RSA examinations (days/weeks)
 Method of image acquisition and scanner or system details as well as image resolution
 Number of patients for whom double examinations were performed
 Cut-off level for CN and ME
 Formula used to calculate confidence interval for precision
 Angular rotation sequence defined (if relevant)
Suggested presentation of standardized output for a clinical RSA study
  159 in total

1.  All-polyethylene versus metal-backed and stemmed tibial components in cemented total knee arthroplasty. A prospective, randomised RSA study.

Authors:  G Adalberth; K G Nilsson; S Byström; K Kolstad; J Milbrink
Journal:  J Bone Joint Surg Br       Date:  2001-08

2.  Micromotion between the half bearings in the interax prosthesis: a roentgen stereophotogrammetric analysis.

Authors:  M Marcacci; R Soavi; I Loreti; L Bragonzoni; F Iacono; A Visani
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

3.  The influence of cement viscosity on the early migration of a tapered polished femoral stem.

Authors:  S Glyn-Jones; J Hicks; J Alfaro-Adrian; H S Gill; P McLardy-Smith; D W Murray
Journal:  Int Orthop       Date:  2003-08-12       Impact factor: 3.075

4.  Stability of the Birmingham hip resurfacing arthroplasty at two years. A radiostereophotogrammetric analysis study.

Authors:  R Itayem; A Arndt; L Nistor; D McMinn; A Lundberg
Journal:  J Bone Joint Surg Br       Date:  2005-02

5.  Recurrence of varus/valgus deformity after TKR at 3 years' follow-up.

Authors:  Alessandro Russo; Laura Bragonzoni; Claudia Trozzi; Stefano Zaffagnini; Maria Pia Neri; Danilo Bruni; Maurilio Marcacci
Journal:  Knee       Date:  2007-11-28       Impact factor: 2.199

6.  Inducible displacement of a trabecular metal tibial monoblock component.

Authors:  David A J Wilson; Janie L Astephen; Allan W Hennigar; Michael J Dunbar
Journal:  J Arthroplasty       Date:  2009-08-18       Impact factor: 4.757

7.  Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: a ten-year follow-up with radiostereometry.

Authors:  Jon Dahl; Per Söderlund; Bo Nivbrant; Lars Nordsletten; Stephan M Röhrl
Journal:  Int Orthop       Date:  2011-08-26       Impact factor: 3.075

8.  Local peroperative treatment with a bisphosphonate improves the fixation of total knee prostheses: a randomized, double-blind radiostereometric study of 50 patients.

Authors:  Maria Hilding; Per Aspenberg
Journal:  Acta Orthop       Date:  2007-12       Impact factor: 3.717

9.  5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis.

Authors:  Georgios Digas; Johan Kärrholm; Jonas Thanner; Peter Herberts
Journal:  Acta Orthop       Date:  2007-12       Impact factor: 3.717

10.  Excessive distal migration of fiber-mesh coated femoral stems.

Authors:  Thomas Baad-Hansen; Søren Kold; Niels Olsen; Finn Christensen; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-04-19       Impact factor: 3.717

View more
  2 in total

1.  In vitro osteogenic capacity of bone marrow MSCs from postmenopausal women reflect the osseointegration of their cementless hip stems.

Authors:  Jessica J Alm; Niko Moritz; Hannu T Aro
Journal:  Bone Rep       Date:  2016-05-25

2.  Reflections on the RSA guidelines.

Authors:  Bart G Pijls
Journal:  Acta Orthop       Date:  2020-05-12       Impact factor: 3.717

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.