Comparison of two digital radiostereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom.

Charles R Bragdon1, Daniel M Estok, Henrik Malchau, Johan Kärrholm, Xunhua Yuan, Robert Bourne, Jean Veldhoven, William H Harris.   

Abstract

Radiostereometric analysis (RSA) has been used extensively to evaluate the magnitude and direction of penetration of the femoral head into the acetabular component of a total hip replacement as a result of polyethylene wear and creep. The accuracy and precision of an RSA study depends on several factors, including the radiographic technique, the analytical software, and the positioning of the tantalum markers. This study had three sequential purposes. First, an in vitro phantom model was used to quantify the accuracy and precision of digital images versus conventional radiography in RSA measurements of penetration of the femoral head into the acetabular shell in a total hip replacement. The Umeå RSA software package was used for analysis of both the conventional films, which were digitized at a resolution of 300 DPI, and digital radiographs, which were converted from a DICOM format at a resolution of 218 DPI. Digital radiography was found to be superior. Next, two methods of RSA analysis currently in use for determining femoral head penetration into polyethylene of total joint replacements were compared. Using the phantom model, we compared the Umeå RSA system (Biomedical Innovations AB) to the RSA-CMS (RSA Clinical Measurement Solution) and in both cases used the digital radiographs. The Umeå RSA system was found to be superior. Finally, two methods of marking the position of the acetabular component with tantalum beads were compared: one in which beads were inserted into previously described towers protruding from the back of the acetabular shell and another in which beads were placed into the peripheral flange of the polyethylene liner using the Umeå RSA analysis system of the digital radiographs. The results using the two marker configurations were similar.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15099649     DOI: 10.1016/j.orthres.2003.09.004

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  9 in total

1.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

2.  The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures.

Authors:  Lucian B Solomon; Aaron W Stevenson; Stuart A Callary; Thomas R Sullivan; Donald W Howie; Mellick J Chehade
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

3.  Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases.

Authors:  Audrey Nebergall; Charles Bragdon; Anne Antonellis; Johan Kärrholm; Rickard Brånemark; Henrik Malchau
Journal:  Acta Orthop       Date:  2012-04-11       Impact factor: 3.717

4.  Precision of radiostereometric analysis (RSA) of acetabular cup stability and polyethylene wear improved by adding tantalum beads to the liner.

Authors:  Audrey K Nebergall; Kevin Rader; Henrik Palm; Henrik Malchau; Meridith E Greene
Journal:  Acta Orthop       Date:  2015-05-26       Impact factor: 3.717

5.  Stability and migration across femoral varus derotation osteotomies in children with neuromuscular disorders.

Authors:  Peter Buxbom; Stig Sonne-Holm; Niels Ellitsgaard; Christian Wong
Journal:  Acta Orthop       Date:  2016-11-28       Impact factor: 3.717

Review 6.  Patient Weight-bearing after Pelvic Fracture Surgery-A Systematic Review of the Literature: What is the Modern Evidence Base?

Authors:  Mark Rickman; Bjorn-Christian Link; Lucian B Solomon
Journal:  Strategies Trauma Limb Reconstr       Date:  2019 Jan-Apr

7.  The superior accuracy of a novel method in total hip wear calculations following radiographic measurement.

Authors:  Kazutaka So; Koji Goto; Atsushi Kawaguchi; Yutaka Kuroda; Shuichi Matsuda
Journal:  BMC Musculoskelet Disord       Date:  2022-02-09       Impact factor: 2.362

8.  Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear: A phantom study.

Authors:  M Stilling; S Kold; S de Raedt; N T Andersen; O Rahbek; K Søballe
Journal:  Bone Joint Res       Date:  2012-08-01       Impact factor: 5.853

9.  Mechanical properties during healing of Achilles tendon ruptures to predict final outcome: a pilot Roentgen stereophotogrammetric analysis in 10 patients.

Authors:  Thorsten Schepull; Joanna Kvist; Christer Andersson; Per Aspenberg
Journal:  BMC Musculoskelet Disord       Date:  2007-11-26       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.