Literature DB >> 21516240

Comparison of 3D OS-EM and 4D MAP-RBI-EM reconstruction algorithms for cardiac motion abnormality classification using a motion observer.

Jing Tang1, Taek-Soo Lee, Xin He, W Paul Segars, Benjamin M W Tsui.   

Abstract

Using a heart motion observer, we compared the performance of two image reconstruction techniques, a 3D OS-EM algorithm with post Butterworth spatial filtering and a 4D MAP-RBI-EM algorithm. The task was to classify gated myocardial perfusion (GMP) SPECT images of beating hearts with or without regional motion abnormalities. Noise-free simulated GMP SPECT projection data was generated from two 4D NCAT beating heart phantom models, one with normal motion and the other with a 50% motion defect in a pie-shaped wedge region-of-interest (ROI) in the anterior-lateral left ventricular wall. The projection data were scaled to clinical GMP SPECT count level before Poisson noise was simulated to generate 40 noise realizations. The noise-free and noisy projection data were reconstructed using the two reconstruction algorithms, parameters chosen to optimize the tradeoff between image bias and noise. As a motion observer, a 3D motion estimation method previously developed was applied to estimate the radial motion on the ROI from two adjacent gates. The receiver operating characteristic (ROC) curves were computed for radial motion magnitudes corresponding to each reconstruction technique. The area under the ROC curve (AUC) was calculated as an index for classification of regional motion. The reconstructed images with better bias and noise tradeoff were found to offer better classification for hearts with or without regional motion defects. The 3D cardiac motion estimation algorithm, serving as a heart motion observer, was better able to distinguish the abnormal from the normal regional motion in GMP SPECT images obtained from the 4D MAP-RBI-EM algorithm than from the 3D OS-EM algorithm with post Butterworth spatial filtering.

Entities:  

Year:  2010        PMID: 21516240      PMCID: PMC3081135          DOI: 10.1109/TNS.2010.2050604

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  14 in total

1.  Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT.

Authors:  Eric C Frey; Karen L Gilland; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

2.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

3.  Computation of 3-D velocity fields from 3-D cine CT images of a human heart.

Authors:  S M Song; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

4.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

5.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

6.  Quantitative study of cardiac motion estimation and abnormality classification in emission computed tomography.

Authors:  Jing Tang; W Paul Segars; Taek-Soo Lee; Xin He; Arman Rahmim; Benjamin M W Tsui
Journal:  Med Eng Phys       Date:  2011-01-26       Impact factor: 2.242

7.  Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women.

Authors:  R Taillefer; E G DePuey; J E Udelson; G A Beller; Y Latour; F Reeves
Journal:  J Am Coll Cardiol       Date:  1997-01       Impact factor: 24.094

8.  Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models.

Authors:  Alexander I Veress; W Paul Segars; Jeffrey A Weiss; Benjamin M W Tsui; Grant T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2006-12       Impact factor: 10.048

9.  Reliable and computationally efficient maximum-likelihood estimation of "proper" binormal ROC curves.

Authors:  Lorenzo L Pesce; Charles E Metz
Journal:  Acad Radiol       Date:  2007-07       Impact factor: 3.173

10.  Combined assessment of myocardial perfusion and left ventricular function with exercise technetium-99m sestamibi gated single-photon emission computed tomography can differentiate between ischemic and nonischemic dilated cardiomyopathy.

Authors:  P G Danias; A W Ahlberg; B A Clark; F Messineo; M G Levine; C C McGill; A Mann; J Clive; J E Dougherty; D D Waters; G V Heller
Journal:  Am J Cardiol       Date:  1998-11-15       Impact factor: 2.778

View more
  2 in total

1.  Numerical Surrogates for Human Observers in Myocardial Motion Evaluation From SPECT Images.

Authors:  Thibault Marin; Mahdi M Kalayeh; Felipe M Parages; Jovan G Brankov
Journal:  IEEE Trans Med Imaging       Date:  2013-08-22       Impact factor: 10.048

2.  Development of a 4D Digital Phantom for Tracer Kinetic Modeling and Analysis of Dynamic Perfusion PET and SPECT Simulation Studies.

Authors:  George S K Fung; Takahiro Higuchi; Min Jae Park; W Paul Segars; Benjamin M W Tsui
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2011-10
  2 in total