Literature DB >> 8779426

Analytical properties of the nanoelectrospray ion source.

M Wilm1, M Mann.   

Abstract

The nanoelectrospray ion source (nanoES) has recently been developed and described theoretically. It is different from conventional electrospray sources and from other miniaturized electrospray sources by (i) its 1-2 microns spraying orifice achieved by pulling the spraying capillary to a fine tip, (ii) its very low flow rate of approximately 20 nL/min and the small size of droplets it generates, and (iii) the absence of solvent pumps and inlet valves. The fabrication and operation of nanoES needles is described in detail. Solutions with up to 0.1 M salt contents could be sprayed without sheath flow or pneumatic assist. Improved desolvation in nanoES led to instrument-limited resolution of the signals of a glycoprotein and the ability to signal average extensively allowed the C-terminal sequencing of a 40 kDa protein. Extensive mass spectrometric and tandem mass spectrometric investigation of the components of an unseparated peptide mixture was demonstrated by verification of 93% of the sequence of carbonic anhydrase. A rapid and robust desalting/concentration step coupled to the nanoES procedure allows the direct analysis of impure samples such as peptide mixtures extracted after in-gel digestion.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8779426     DOI: 10.1021/ac9509519

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  334 in total

1.  SCF ubiquitin protein ligases and phosphorylation-dependent proteolysis.

Authors:  A R Willems; T Goh; L Taylor; I Chernushevich; A Shevchenko; M Tyers
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-09-29       Impact factor: 6.237

2.  Sheathless preconcentration-capillary zone electrophoresis-mass spectrometry applied to peptide analysis.

Authors:  M B Barroso; A P de Jong
Journal:  J Am Soc Mass Spectrom       Date:  1999-12       Impact factor: 3.109

3.  Use of two-dimensional gel electrophoresis to measure changes in synovial fluid proteins from patients with rheumatoid arthritis treated with antibody to CD4.

Authors:  M A Smith; S K Bains; J C Betts; E H Choy; E D Zanders
Journal:  Clin Diagn Lab Immunol       Date:  2001-01

4.  Attomole level protein sequencing by Edman degradation coupled with accelerator mass spectrometry.

Authors:  M Miyashita; J M Presley; B A Buchholz; K S Lam; Y M Lee; J S Vogel; B D Hammock
Journal:  Proc Natl Acad Sci U S A       Date:  2001-04-03       Impact factor: 11.205

5.  Supercharged protein and peptide ions formed by electrospray ionization.

Authors:  A T Iavarone; J C Jurchen; E R Williams
Journal:  Anal Chem       Date:  2001-04-01       Impact factor: 6.986

6.  Single isolated droplets with net charge as a source of ions

Authors: 
Journal:  J Am Soc Mass Spectrom       Date:  2000-05       Impact factor: 3.109

7.  Protein identification by in-gel digestion, high-performance liquid chromatography, and mass spectrometry: peptide analysis by complementary ionization techniques.

Authors:  K F Medzihradszky; H Leffler; M A Baldwin; A L Burlingame
Journal:  J Am Soc Mass Spectrom       Date:  2001-02       Impact factor: 3.109

8.  Nanoelectrospray--more than just a minimized-flow electrospray ionization source.

Authors:  R Juraschek; T Dülcks; M Karas
Journal:  J Am Soc Mass Spectrom       Date:  1999-04       Impact factor: 3.109

9.  Overexpression of recombinant proteins with a C-terminal thiocarboxylate: implications for protein semisynthesis and thiamin biosynthesis.

Authors:  C Kinsland; S V Taylor; N L Kelleher; F W McLafferty; T P Begley
Journal:  Protein Sci       Date:  1998-08       Impact factor: 6.725

10.  Insights into analyte electrolysis in an electrospray emitter from chronopotentiometry experiments and mass transport calculations

Authors: 
Journal:  J Am Soc Mass Spectrom       Date:  2000-11       Impact factor: 3.109

View more