Literature DB >> 18228576

Functional assessment of the kidney from magnetic resonance and computed tomography renography: impulse retention approach to a multicompartment model.

Jeff L Zhang1, Henry Rusinek, Louisa Bokacheva, Lilach O Lerman, Qun Chen, Chekema Prince, Niels Oesingmann, Ting Song, Vivian S Lee.   

Abstract

A three-compartment model is proposed for analyzing magnetic resonance renography (MRR) and computed tomography renography (CTR) data to derive clinically useful parameters such as glomerular filtration rate (GFR) and renal plasma flow (RPF). The model fits the convolution of the measured input and the predefined impulse retention functions to the measured tissue curves. A MRR study of 10 patients showed that relative root mean square errors by the model were significantly lower than errors for a previously reported three-compartmental model (11.6% +/- 4.9 vs 15.5% +/- 4.1; P < 0.001). GFR estimates correlated well with reference values by (99m)Tc-DTPA scintigraphy (correlation coefficient r = 0.82), and for RPF, r = 0.80. Parameter-sensitivity analysis and Monte Carlo simulation indicated that model parameters could be reliably identified. When the model was applied to CTR in five pigs, expected increases in RPF and GFR due to acetylcholine were detected with greater consistency than with the previous model. These results support the reliability and validity of the new model in computing GFR, RPF, and renal mean transit times from MR and CT data. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18228576      PMCID: PMC2735648          DOI: 10.1002/mrm.21489

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  33 in total

1.  Calculation of the renal perfusion and glomerular filtration rate from the renal impulse response obtained with MRI.

Authors:  L Hermoye; L Annet; Ph Lemmerling; F Peeters; F Jamar; P Gianello; S Van Huffel; B E Van Beers
Journal:  Magn Reson Med       Date:  2004-05       Impact factor: 4.668

2.  Performance of an automated segmentation algorithm for 3D MR renography.

Authors:  Henry Rusinek; Yuri Boykov; Manmeen Kaur; Samson Wong; Louisa Bokacheva; Jan B Sajous; Ambrose J Huang; Samantha Heller; Vivian S Lee
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

3.  Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function.

Authors:  J D Krier; E L Ritman; Z Bajzer; J C Romero; A Lerman; L O Lerman
Journal:  Am J Physiol Renal Physiol       Date:  2001-10

4.  Diuresis renography and parenchymal transit times in the assessment of renal pelvic dilatation.

Authors:  E W Lupton; R S Lawson; R A Shields; H J Testa
Journal:  Nucl Med Commun       Date:  1984-07       Impact factor: 1.690

5.  First-pass measurements of regional blood flow with external detectors.

Authors:  N A Mullani; K L Gould
Journal:  J Nucl Med       Date:  1983-07       Impact factor: 10.057

6.  Glomerular filtration rate: assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney.

Authors:  Laurence Annet; Laurent Hermoye; Frank Peeters; François Jamar; Jean-Paul Dehoux; Bernard E Van Beers
Journal:  J Magn Reson Imaging       Date:  2004-11       Impact factor: 4.813

7.  Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI.

Authors:  D Baumann; M Rudin
Journal:  Magn Reson Imaging       Date:  2000-06       Impact factor: 2.546

8.  A pathophysiologic study of the kidney tubule to optimize organ preservation solutions.

Authors:  Niaz Ahmad; Lutz Hostert; Julian R Pratt; Katharine J Billar; David J Potts; J Peter A Lodge
Journal:  Kidney Int       Date:  2004-07       Impact factor: 10.612

9.  Physiologically based pharmacokinetic model parameter estimation and sensitivity and variability analyses for acrylonitrile disposition in humans.

Authors:  Lisa M Sweeney; Michael L Gargas; Dale E Strother; Gregory L Kedderis
Journal:  Toxicol Sci       Date:  2003-01       Impact factor: 4.849

Review 10.  MR imaging of renal function.

Authors:  Ambrose J Huang; Vivian S Lee; Henry Rusinek
Journal:  Radiol Clin North Am       Date:  2003-09       Impact factor: 2.303

View more
  32 in total

Review 1.  [Functional magnetic resonance imaging of the kidneys].

Authors:  R S Lanzman; M Notohamiprodjo; H J Wittsack
Journal:  Radiologe       Date:  2015-12       Impact factor: 0.635

2.  Angiotensin-converting enzyme inhibitor-enhanced MR renography: repeated measures of GFR and RPF in hypertensive patients.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Qun Chen; Pippa Storey; Keyma Prince; Elizabeth M Hecht; Danny C Kim; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2009-01-21

3.  Prospective pediatric study comparing glomerular filtration rate estimates based on motion-robust dynamic contrast-enhanced magnetic resonance imaging and serum creatinine (eGFR) to 99mTc DTPA.

Authors:  Sila Kurugol; Onur Afacan; Richard S Lee; Catherine M Seager; Michael A Ferguson; Deborah R Stein; Reid C Nichols; Monet Dugan; Alto Stemmer; Simon K Warfield; Jeanne S Chow
Journal:  Pediatr Radiol       Date:  2020-01-27

4.  Performance of an efficient image-registration algorithm in processing MR renography data.

Authors:  Christopher C Conlin; Jeff L Zhang; Florian Rousset; Clement Vachet; Yangyang Zhao; Kathryn A Morton; Kristi Carlston; Guido Gerig; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

5.  MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: noninvasive regional assessment of renal function.

Authors:  Andrew L Wentland; Nathan S Artz; Sean B Fain; Thomas M Grist; Arjang Djamali; Elizabeth A Sadowski
Journal:  Nephrol Dial Transplant       Date:  2011-05-28       Impact factor: 5.992

Review 6.  Functional Magnetic Resonance Imaging of the Kidneys-With and Without Gadolinium-Based Contrast.

Authors:  Jeff L Zhang
Journal:  Adv Chronic Kidney Dis       Date:  2017-05       Impact factor: 3.620

Review 7.  Tracer-kinetic modeling of dynamic contrast-enhanced MRI and CT: a primer.

Authors:  Michael Ingrisch; Steven Sourbron
Journal:  J Pharmacokinet Pharmacodyn       Date:  2013-04-06       Impact factor: 2.745

8.  Measurement of renal tissue oxygenation with blood oxygen level-dependent MRI and oxygen transit modeling.

Authors:  Jeff L Zhang; Glen Morrell; Henry Rusinek; Lizette Warner; Pierre-Hugues Vivier; Alfred K Cheung; Lilach O Lerman; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2014-01-22

9.  Measurement of murine kidney functional biomarkers using DCE-MRI: A multi-slice TRICKS technique and semi-automated image processing algorithm.

Authors:  Kai Jiang; Hui Tang; Prasanna K Mishra; Slobodan I Macura; Lilach O Lerman
Journal:  Magn Reson Imaging       Date:  2019-08-20       Impact factor: 2.546

10.  Use of cardiac output to improve measurement of input function in quantitative dynamic contrast-enhanced MRI.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Qun Chen; Pippa Storey; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.