Calculation of the renal perfusion and glomerular filtration rate from the renal impulse response obtained with MRI.

L Hermoye1, L Annet, Ph Lemmerling, F Peeters, F Jamar, P Gianello, S Van Huffel, B E Van Beers.   

Abstract

The aim of this study was to assess the importance of deconvolution for the calculation of renal perfusion and glomerular filtration rate (GFR) on the basis of concentration-time curves as measured with perfusion MRI. Six rabbits were scanned dynamically after injection of a gadolinium chelate. Concentration-time curves were generated by manually drawing regions of interest in the aorta and the renal cortex. To remove the dependency on the arterial input function, a regularized structured total least-squares deconvolution algorithm was used to calculate the renal impulse response. This curve was fitted by the sum of two gamma variate functions, corresponding to the passage of the contrast agent in the glomeruli and the proximal convoluted tubules. Tracer kinetics models were applied to these two functions to obtain the renal perfusion and GFR. For comparison, these two parameters were also calculated on the basis of the renal concentration-time curve before deconvolution. The renal perfusion values correlated well (r = 0.9, P = 0.014) with the values calculated by a validated upslope method. The GFR values correlated well (r = 0.9, P = 0.014) with the values obtained from the clearance of (51)Cr-EDTA. A comparison of the values obtained with and without deconvolution demonstrated the necessity of deconvolution. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15122685     DOI: 10.1002/mrm.20026

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

Review 1.  Analysis of contrast-enhanced MR images to assess renal function.

Authors:  N Michoux; J-P Vallée; A Pechère-Bertschi; X Montet; L Buehler; B E Van Beers
Journal:  MAGMA       Date:  2006-08-12       Impact factor: 2.310

2.  Functional assessment of the kidney from magnetic resonance and computed tomography renography: impulse retention approach to a multicompartment model.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Lilach O Lerman; Qun Chen; Chekema Prince; Niels Oesingmann; Ting Song; Vivian S Lee
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

3.  Angiotensin-converting enzyme inhibitor-enhanced MR renography: repeated measures of GFR and RPF in hypertensive patients.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Qun Chen; Pippa Storey; Keyma Prince; Elizabeth M Hecht; Danny C Kim; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2009-01-21

4.  Test-retest reliability of freesurfer measurements within and between sites: Effects of visual approval process.

Authors:  Zafer Iscan; Tony B Jin; Alexandria Kendrick; Bryan Szeglin; Hanzhang Lu; Madhukar Trivedi; Maurizio Fava; Patrick J McGrath; Myrna Weissman; Benji T Kurian; Phillip Adams; Sarah Weyandt; Marisa Toups; Thomas Carmody; Melvin McInnis; Cristina Cusin; Crystal Cooper; Maria A Oquendo; Ramin V Parsey; Christine DeLorenzo
Journal:  Hum Brain Mapp       Date:  2015-05-28       Impact factor: 5.038

5.  Measurement of Murine Single-Kidney Glomerular Filtration Rate Using Dynamic Contrast-Enhanced MRI.

Authors:  Kai Jiang; Hui Tang; Prasanna K Mishra; Slobodan I Macura; Lilach O Lerman
Journal:  Magn Reson Med       Date:  2017-10-16       Impact factor: 4.668

6.  MR urography in children. Part 1: how we do the F0 technique.

Authors:  Pierre-Hugues Vivier; Michael Dolores; Melissa Taylor; Frederic Elbaz; Agnes Liard; Jean-Nicolas Dacher
Journal:  Pediatr Radiol       Date:  2010-02-25

7.  Quantitative MR measures of intrarenal perfusion in the assessment of transplanted kidneys: initial experience.

Authors:  Andrew L Wentland; Elizabeth A Sadowski; Arjang Djamali; Thomas M Grist; Bryan N Becker; Sean B Fain
Journal:  Acad Radiol       Date:  2009-06-17       Impact factor: 3.173

8.  Quantitative high-resolution renal perfusion imaging using 3-dimensional through-time radial generalized autocalibrating partially parallel acquisition.

Authors:  Katherine L Wright; Yong Chen; Haris Saybasili; Mark A Griswold; Nicole Seiberlich; Vikas Gulani
Journal:  Invest Radiol       Date:  2014-10       Impact factor: 6.016

Review 9.  Assessment of renal function with dynamic contrast-enhanced MR imaging.

Authors:  Louisa Bokacheva; Henry Rusinek; Jeff L Zhang; Vivian S Lee
Journal:  Magn Reson Imaging Clin N Am       Date:  2008-11       Impact factor: 2.266

10.  Modeling of nanotherapeutics delivery based on tumor perfusion.

Authors:  Anne L van de Ven; Behnaz Abdollahi; Carlos J Martinez; Lacey A Burey; Melissa D Landis; Jenny C Chang; Mauro Ferrari; Hermann B Frieboes
Journal:  New J Phys       Date:  2013-05-08       Impact factor: 3.729

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.