Literature DB >> 21622986

MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: noninvasive regional assessment of renal function.

Andrew L Wentland1, Nathan S Artz, Sean B Fain, Thomas M Grist, Arjang Djamali, Elizabeth A Sadowski.   

Abstract

BACKGROUND: Magnetic resonance imaging (MRI) may be a useful adjunct to current methods of evaluating renal function. MRI is a noninvasive imaging modality that has the ability to evaluate the kidneys regionally, which is lacking in current clinical methods. Other investigators have evaluated renal function with MRI-based measurements, such as with techniques to measure cortical and medullary perfusion, oxygen bioavailability and total renal blood flow (TRBF). However, use of all three techniques simultaneously, and therefore the relationships between these MRI-derived functional parameters, have not been reported previously.
METHODS: To evaluate the ability of these MRI techniques to track changes in renal function, we scanned 11 swine during a state of hyperperfusion with acetylcholine and a saline bolus and subsequently scanned during a state of hypoperfusion with the prolonged use of isoflurane anesthesia. For each time point, measurements of perfusion, oxygen bioavailability and TRBF were acquired. Measurements of perfusion and oxygen bioavailability were compared with measurements of TRBF for all swine across all time points.
RESULTS: Cortical perfusion, cortical oxygen bioavailability, medullary oxygen bioavailability and TRBF significantly increased with the acetylcholine challenge. Cortical perfusion, medullary perfusion, cortical oxygen bioavailability and TRBF significantly decreased during isoflurane anesthesia. Cortical perfusion (Spearman's correlation coefficient = 0.68; P < 1 × 10(-6)) and oxygen bioavailability (Spearman's correlation coefficient = -0.60; P < 0.0001) correlated significantly with TRBF, whereas medullary perfusion and oxygen bioavailability did not correlate with TRBF.
CONCLUSIONS: Our results demonstrate expected changes given the pharmacologically induced changes in renal function. Maintenance of the medullary oxygen bioavailability in low blood flow states may reflect the autoregulation particular to this region of the kidney. The ability to non-invasively measure all three parameters of kidney function in a single MRI examination and to evaluate the relationships between these functional parameters is potentially useful for evaluating the state of the human kidneys in situ in future studies.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21622986      PMCID: PMC3350337          DOI: 10.1093/ndt/gfr199

Source DB:  PubMed          Journal:  Nephrol Dial Transplant        ISSN: 0931-0509            Impact factor:   5.992


  33 in total

1.  Quantification of renal blood flow with contrast-enhanced ultrasound.

Authors:  K Wei; E Le; J P Bin; M Coggins; J Thorpe; S Kaul
Journal:  J Am Coll Cardiol       Date:  2001-03-15       Impact factor: 24.094

2.  Assessment of T1 and T2* effects in vivo and ex vivo using iron oxide nanoparticles in steady state--dependence on blood volume and water exchange.

Authors:  Atle Bjørnerud; Lars O Johansson; Karen Briley-Saebø; Håkan K Ahlström
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  FAIR true-FISP perfusion imaging of the kidneys.

Authors:  Petros Martirosian; Uwe Klose; Irina Mader; Fritz Schick
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

Review 4.  Functional renal MR imaging.

Authors:  Ambrose J Huang; Vivian S Lee; Henry Rusinek
Journal:  Magn Reson Imaging Clin N Am       Date:  2004-08       Impact factor: 2.266

5.  Assessment of renal hemodynamics and function in pigs with 64-section multidetector CT: comparison with electron-beam CT.

Authors:  Elena Daghini; Andrew N Primak; Alejandro R Chade; James D Krier; Xiang-Yang Zhu; Erik L Ritman; Cynthia H McCollough; Lilach O Lerman
Journal:  Radiology       Date:  2007-05       Impact factor: 11.105

6.  Functional assessment of the kidney from magnetic resonance and computed tomography renography: impulse retention approach to a multicompartment model.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Lilach O Lerman; Qun Chen; Chekema Prince; Niels Oesingmann; Ting Song; Vivian S Lee
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

7.  Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function.

Authors:  J D Krier; E L Ritman; Z Bajzer; J C Romero; A Lerman; L O Lerman
Journal:  Am J Physiol Renal Physiol       Date:  2001-10

8.  Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model.

Authors:  Nathan S Artz; Andrew L Wentland; Elizabeth A Sadowski; Arjang Djamali; Thomas M Grist; Songwon Seo; Sean B Fain
Journal:  Invest Radiol       Date:  2011-02       Impact factor: 6.016

9.  Regional blood flow during isoflurane and halothane anesthesia.

Authors:  S Gelman; K C Fowler; L R Smith
Journal:  Anesth Analg       Date:  1984-06       Impact factor: 5.108

10.  Blood oxygen level-dependent measurement of acute intra-renal ischemia.

Authors:  Laurent Juillard; Lilach O Lerman; David G Kruger; John A Haas; Brian C Rucker; Jason A Polzin; Stephen J Riederer; Juan C Romero
Journal:  Kidney Int       Date:  2004-03       Impact factor: 10.612

View more
  7 in total

Review 1.  Contrast-enhanced ultrasound: A promising method for renal microvascular perfusion evaluation.

Authors:  Ling Wang; Chandra Mohan
Journal:  J Transl Int Med       Date:  2016-09-23

2.  Diagnostic value of quantitative contrast-enhanced ultrasound (CEUS) for early detection of renal hyperperfusion in diabetic kidney disease.

Authors:  Ling Wang; Jian Wu; Jia-Fen Cheng; Xin-Ying Liu; Fang Ma; Le-Hang Guo; Jun-Mei Xu; Tianfu Wu; Chandra Mohan; Ai Peng; Hui-Xiong Xu; Ya-Xiang Song
Journal:  J Nephrol       Date:  2015-02-25       Impact factor: 3.902

3.  Measurements of wall shear stress and aortic pulse wave velocity in swine with familial hypercholesterolemia.

Authors:  Andrew L Wentland; Oliver Wieben; Dhanansayan Shanmuganayagam; Christian G Krueger; Jennifer J Meudt; Daniel Consigny; Leonardo Rivera; Patrick E McBride; Jess D Reed; Thomas M Grist
Journal:  J Magn Reson Imaging       Date:  2014-06-25       Impact factor: 4.813

4.  Parameterisation of multi-scale continuum perfusion models from discrete vascular networks.

Authors:  Eoin R Hyde; Christian Michler; Jack Lee; Andrew N Cookson; Radek Chabiniok; David A Nordsletten; Nicolas P Smith
Journal:  Med Biol Eng Comput       Date:  2013-01-24       Impact factor: 2.602

5.  Longitudinal Assessment of Renal Perfusion and Oxygenation in Transplant Donor-Recipient Pairs Using Arterial Spin Labeling and Blood Oxygen Level-Dependent Magnetic Resonance Imaging.

Authors:  David J Niles; Nathan S Artz; Arjang Djamali; Elizabeth A Sadowski; Thomas M Grist; Sean B Fain
Journal:  Invest Radiol       Date:  2016-02       Impact factor: 6.016

6.  Assessment of Perfusion and Oxygenation of the Human Renal Cortex and Medulla by Quantitative MRI during Handgrip Exercise.

Authors:  Bryan Thomas Haddock; Susan T Francis; Henrik B W Larsson; Ulrik B Andersen
Journal:  J Am Soc Nephrol       Date:  2018-09-11       Impact factor: 10.121

7.  Detection of renal allograft rejection using blood oxygen level-dependent and diffusion weighted magnetic resonance imaging: a retrospective study.

Authors:  Guangyi Liu; Fei Han; Wenbo Xiao; Qidong Wang; Ying Xu; Jianghua Chen
Journal:  BMC Nephrol       Date:  2014-10-01       Impact factor: 2.388

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.