Literature DB >> 27579717

Self-gated MRI of multiple beat morphologies in the presence of arrhythmias.

Francisco Contijoch1, Srikant Kamesh Iyer2, James J Pilla2, Paul Yushkevich2, Joseph H Gorman3, Robert C Gorman3, Harold Litt2, Yuchi Han4, Walter R T Witschey2.   

Abstract

PURPOSE: Develop self-gated MRI for distinct heartbeat morphologies in subjects with arrhythmias.
METHODS: Golden angle radial data was obtained in seven sinus and eight arrhythmias subjects. An image-based cardiac navigator was derived from single-shot images, distinct beat types were identified, and images were reconstructed for repeated morphologies. Image sharpness, contrast, and volume variation were quantified and compared with self-gated MRI. Images were scored for image quality and artifacts. Hemodynamic parameters were computed for each distinct beat morphology in bigeminy and trigeminy subjects and for sinus beats in patients with infrequent premature ventricular contractions.
RESULTS: Images of distinct beat types were reconstructed except for two patients with infrequent premature ventricular contractions. Image contrast and sharpness were similar to sinus self-gated images (contrast = 0.45 ± 0.13 and 0.43 ± 0.15; sharpness = 0.21 ± 0.11 and 0.20 ± 0.05). Visual scoring was highest in self-gated images (4.1 ± 0.3) compared with real-time (3.9 ± 0.4) and ECG-gated cine (3.4 ± 1.5). ECG-gated cine had less artifacts than self-gating (2.3 ± 0.7 and 2.1 ± 0.2), but was affected by misgating in two subjects. Among arrhythmia subjects, post-extrasystole/sinus (58.1 ± 8.6 mL) and interrupted sinus (61.4 ± 5.9 mL) stroke volume was higher than extrasystole (32.0 ± 16.5 mL; P < 0.02).
CONCLUSION: Self-gated imaging can reconstruct images during ectopy and allowed for quantification of hemodynamic function of different beat morphologies. Magn Reson Med 78:678-688, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  arrhythmias; cardiovascular magnetic resonance; golden angle; navigators; non-Cartesian; nonperiodic motion; radial; real time; retrospective cine; sensitivity encoding

Mesh:

Year:  2016        PMID: 27579717      PMCID: PMC5332534          DOI: 10.1002/mrm.26381

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  40 in total

1.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

3.  Self-gated tissue phase mapping using golden angle radial sparse SENSE.

Authors:  Jan Paul; Stefan Wundrak; Peter Bernhardt; Wolfgang Rottbauer; Heiko Neumann; Volker Rasche
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

4.  Gadgetron: an open source framework for medical image reconstruction.

Authors:  Michael Schacht Hansen; Thomas Sangild Sørensen
Journal:  Magn Reson Med       Date:  2012-07-12       Impact factor: 4.668

5.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

Authors:  Gust H Bardy; Kerry L Lee; Daniel B Mark; Jeanne E Poole; Douglas L Packer; Robin Boineau; Michael Domanski; Charles Troutman; Jill Anderson; George Johnson; Steven E McNulty; Nancy Clapp-Channing; Linda D Davidson-Ray; Elizabeth S Fraulo; Daniel P Fishbein; Richard M Luceri; John H Ip
Journal:  N Engl J Med       Date:  2005-01-20       Impact factor: 91.245

6.  Recurrence of PVCs in patients with PVC-induced cardiomyopathy.

Authors:  Kazim Baser; Hatice Duygu Bas; Troy LaBounty; Miki Yokokawa; Eric Good; Rakesh Latchamsetty; Fred Morady; Frank Bogun
Journal:  Heart Rhythm       Date:  2015-03-16       Impact factor: 6.343

7.  Real-time magnetic resonance imaging technique for determining left ventricle pressure-volume loops.

Authors:  Walter R T Witschey; Francisco Contijoch; Jeremy R McGarvey; Victor A Ferrari; Michael S Hansen; Madonna E Lee; Satoshi Takebayashi; Chikashi Aoki; Julio A Chirinos; Paul A Yushkevich; Joseph H Gorman; James J Pilla; Robert C Gorman
Journal:  Ann Thorac Surg       Date:  2014-03-12       Impact factor: 4.330

8.  Quantification of Left Ventricular Function With Premature Ventricular Complexes Reveals Variable Hemodynamics.

Authors:  Francisco Contijoch; Kelly Rogers; Hannah Rears; Mohammed Shahid; Peter Kellman; Joseph Gorman; Robert C Gorman; Paul Yushkevich; Erica S Zado; Gregory E Supple; Francis E Marchlinski; Walter R T Witschey; Yuchi Han
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-04

9.  User-initialized active contour segmentation and golden-angle real-time cardiovascular magnetic resonance enable accurate assessment of LV function in patients with sinus rhythm and arrhythmias.

Authors:  Francisco Contijoch; Walter R T Witschey; Kelly Rogers; Hannah Rears; Michael Hansen; Paul Yushkevich; Joseph Gorman; Robert C Gorman; Yuchi Han
Journal:  J Cardiovasc Magn Reson       Date:  2015-05-21       Impact factor: 5.364

10.  Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease.

Authors:  Sohrab Fratz; Taylor Chung; Gerald F Greil; Margaret M Samyn; Andrew M Taylor; Emanuela R Valsangiacomo Buechel; Shi-Joon Yoo; Andrew J Powell
Journal:  J Cardiovasc Magn Reson       Date:  2013-06-13       Impact factor: 5.364

View more
  5 in total

1.  Multiparametric Magnetic Resonance Imaging in the Assessment of Pulmonary Hypertension: Initial Experience of a One-Stop Study.

Authors:  Gisela M B Meyer; Fernanda B Spilimbergo; Stephan Altmayer; Gabriel S Pacini; Matheus Zanon; Guilherme Watte; Edson Marchiori; Bruno Hochhegger
Journal:  Lung       Date:  2018-02-12       Impact factor: 2.584

2.  Two-dimensional XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration.

Authors:  Eve Piekarski; Teodora Chitiboi; Rebecca Ramb; Larry A Latson; Puneet Bhatla; Li Feng; Leon Axel
Journal:  MAGMA       Date:  2017-10-24       Impact factor: 2.310

3.  Sector-wise golden-angle phase contrast with high temporal resolution for evaluation of left ventricular diastolic dysfunction.

Authors:  Alexander Fyrdahl; Joao G Ramos; Maria J Eriksson; Kenneth Caidahl; Martin Ugander; Andreas Sigfridsson
Journal:  Magn Reson Med       Date:  2019-10-21       Impact factor: 4.668

4.  Closed-loop control of k-space sampling via physiologic feedback for cine MRI.

Authors:  Francisco Contijoch; Yuchi Han; Srikant Kamesh Iyer; Peter Kellman; Gene Gualtieri; Mark A Elliott; Sebastian Berisha; Joseph H Gorman; Robert C Gorman; James J Pilla; Walter R T Witschey
Journal:  PLoS One       Date:  2020-12-29       Impact factor: 3.752

5.  Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring.

Authors:  Maxime Yon; Marylène Delcey; Pierre Bour; William Grissom; Bruno Quesson; Valéry Ozenne
Journal:  Sci Rep       Date:  2022-03-07       Impact factor: 4.996

  5 in total